* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What are the basic safety precautions for using the GODOX ML60II BI?
The GODOX ML60II BI is professional lighting equipment and should be used by professional lighting engineers or under their guidance. Basic safety precautions must always be followed during use, as follows:
1. The product manual must be read and understood before use.
2. Professional lighting is prohibited for children. When children are near, parents or accompanying persons must supervise closely to prevent children from personal injury due to collision with lamps or private use of lamps.
3. This lighting product is not an ordinary lighting product and cannot be used for general lighting. Anyone who has suffered eye damage or has sensitive eyes should avoid using this product.
4. When the lamp is on, it must be used with care. Do not touch high-temperature parts, such as LED lamp beads, to avoid burns.
5. When the lamp is on, it is forbidden to look directly at the lamp beads under any circumstances. Strong light should be used under the guidance of professional lighting engineers. Avoid prolonged exposure to strong light under any circumstances. If eye discomfort, please turn off the lamp in time, suspend use, and seek medical attention in time.
6. If the lamp bead is damaged or deformed by heat, stop using it, and contact the manufacturer, service agent or qualified maintenance personnel to replace the lamp bead in time to avoid accidents.
7. The GODOX ML60II BI is only suitable for use in -10°C to 40°C working environment temperature and normal humidity environment.
8. Do not use damaged equipment or accessories, and wait for professional maintenance personnel to check and repair to confirm being normal before use.
9. During using, if the casing of this product is broken due to being dropped, squeezed or subjected to strong impact, please do not use it, so as to avoid electric shock injury due to contact with internal electronic components.
10. Be sure to unplug equipment from the power outlet before cleaning and repairing. When not in use, do not pull the power cord to unplug the equipment. For normal power-off, please hold both ends of the plug of the equipment with your hands and pull the plug out of power outlet. This equipment needs to be connected to a grounded outlet.
11. This equipment is not waterproof, please keep it dry and do not immerse it in water or other liquids. The equipment should be installed in a dry and ventilated place, and avoid using it in rainy, humid, dusty or overheated environments. Do not place any objects on the lamp or let liquid flow into the lamp to avoid accidents.
12. Do not disassemble the product without permission. If the product fails, it must be checked and repaired by authorized maintenance personnel.
13. Before storing, make sure that the equipment has cooled down completely. For storage, unplug the power cord from the equipment. The equipment should be placed in the carrying case or in a ventilated dry place.
14. Do not place equipment near flammable and volatile solvents such as alcohol and gasoline.
15. Do not use accessories that are not recommended by our factory to avoid fire, electric shock or personal injury.
16. When cleaning, do not wipe it with a damp cloth, please use a dry cloth or a soft cloth to wipe the dirt of the equipment.
17. Please take off the protective cover before using.
18. This product has passed ROHS, CE and FCC certification, please refer to the relevant national standards for use and operation.
What warnings should be considered before using the GODOX ML60II BI?
Before using the GODOX ML60II BI device, please make sure to remove the lamp head protective cover.
Do not dismantle the product without authorization. If the product malfunctions, it must be inspected and repaired by our company or authorized maintenance personnel.
Do not stare at a bright light source.
What are the named parts of the GODOX ML60II BI?
The named parts of the GODOX ML60II BI are:
1. Display
2. FN Button
3. DIM/MODE/ Bluetooth Button
4. DC Input Port
5. Power Switch Dial
6. Godox Mount
7. Thermovent
8. Fan Vent
9. 1/4″ Screw Hole
10. LED Beads
What are the parts of the GODOX ML60II BI NP-F Battery Kit AK-B01?
The parts of the GODOX ML60II BI NP-F Battery Kit AK-B01 are:
1. Grip Holder
2. 1/4″ Screw
3. Direction Adjustment Handle
4. Adjustment Handle Button
5. Locking Wheel for Light Body
6. Battery Case Fixing Buckle
7. Battery Case Push Lock
8. Battery Case Fixing Hole
9. DC Output Port
10. Battery Slot 1
11. Battery Slot 2
12. Battery Level Indicator
13. Battery Level Display Button
14. Battery Attachment/Release Button 1
15. Battery Attachment/Release Button 2
16. Light Stand Retractable Knob
What are the important notes regarding the GODOX ML60II BI NP-F Battery Kit AK-B01?
1. The battery case only supports battery power and does not support charging the batteries.
2. To use the battery case, two NPF-type batteries must be used simultaneously, and single battery usage is not supported.
What are the parts of the GODOX ML60II BI V-mount Battery Kit AK-B02?
The parts of the GODOX ML60II BI V-mount Battery Kit AK-B02 are:
1. 1/4″ Screw Hole
2. Locking Wheel for Light Body
3. Adjustment Handle Button
4. Direction Adjustment Handle
5. Battery Plate Attachment/Release Button
6. Battery Attachment/Release Button
7. Battery Slot
8. Light Stand Retractable Knob
How can the GODOX ML60II BI be powered?
The GODOX ML60II BI can be powered in the following ways:
DC Power Supply: Connect the adapter to AC power, input 20V=3.5A.
NPF Battery Power Supply: Purchase the AK-B01 Battery Accessory Kit, and insert two NPF batteries. Connect the battery case to the light body using the DC cable for power supply.
V-Mount Battery Power Supply: Battery kit AK-B02 is capable of accommodating one 14.8V V-mount battery. You can connect the battery to the light unit using the D-Tap cable to provide power.
How do you install the GODOX ML60II BI AK-B01 Battery Accessory Kit?
While holding the battery case push lock firmly, simultaneously insert the battery case fixing buckle into the battery case fixing hole and push the battery case downward until you hear a “click” sound, indicating that the battery case is securely installed. Use the DC cable to connect one end to the light body and the other end to the battery case. Finally, insert two NPF batteries to power the device.
How do you remove the GODOX ML60II BI AK-B01 Battery Accessory Kit?
After removing the DC cable and NPF batteries, hold down the battery case push lock and push the battery case upward to detach it.
How does the GODOX ML60II BI battery level indicator display the battery level?
The battery case’s battery level indicator displays the battery level as follows: Four green bars indicate a full charge, three green bars indicate 75% remaining, two green bars indicate 50% remaining, one green bar indicates 25% remaining. When the battery level is below one green bar, the display screen will show a low battery warning.
How do you install the GODOX ML60II BI V-mount Battery Kit AK-B02?
Press and hold the V-mount battery plate attachment/release button. Align the battery plate with the fixed hole on the battery case, then push it in until it clicks into place and release your hand to securely install the battery case. Press and hold the V-mount battery attachment/release button. Insert one 14.8V V-mount battery and use one end of the D-Tap adapter cable to connect to the light unit, while the other end is connected to the V-mount battery for power supply.
How do you remove the GODOX ML60II BI V-mount Battery Kit AK-B02?
After removing the D-Tap adapter cable and V-mount battery, press and hold the V-mount battery plate attachment/release button and simultaneously push the battery plate upward with your hand to detach the battery case.
How do you power on or off the GODOX ML60II BI?
After connecting the power supply, turn the power switch dial to ON to power on the device. Turn it to OFF to power off the device.
How do you adjust the color temperature in CCT Mode on the GODOX ML60II BI?
Press the DIM/MODE/ Bluetooth button briefly to switch modes. When the display screen shows “CCT,” it indicates that the current mode is the color temperature mode. Rotate the FN dial to adjust the color temperature. One left rotation decreases the color temperature by 100K, while one right rotation increases it by 100K. The CCT range is 2800-6500K. Quick adjustment is also available.
How do you adjust the brightness in CCT Mode on the GODOX ML60II BI?
Rotate the DIM/MODE/ Bluetooth button to adjust the brightness. One left rotation decreases the brightness by 1%, while one right rotation increases it by 1%. The brightness range is 0%-100%. Quick adjustment is also available.
How do you adjust lighting effects in FX Mode on the GODOX ML60II BI?
Press the DIM/MODE/ Bluetooth button briefly to switch modes. When the display screen shows “FX,” it indicates that the current mode is the FX lighting effects mode. Rotate the DIM/MODE/ Bluetooth button briefly to adjust the brightness. One left rotation decreases the brightness by 1%, while one right rotation increases it by 1%. The brightness range is 0%-100%. Quick adjustment is also available. Press the FN button briefly to select the lighting effect/parameters. Once a specific option is selected, rotate the FN button to adjust the lighting effect/parameters.
What are the available FX types and their adjustable ranges on the GODOX ML60II BI?
The available FX types and their adjustable ranges on the GODOX ML60II BI are:
| No. | FX Icon | FX Type | Option | Adjustable Range |
|---|---|---|---|---|
| 1 | FLASH | SPD | 1-100 | |
| 2 | LIGHTNING | FREQ | RANDOM/2-20 | |
| 3 | CLOUDY | SPD | RANDOM/1-100 | |
| 4 | BROKEN BULB | SPD | 1-100 | |
| 5 | TV | TV | SPD | 1-100 |
| 6 | CANDLE | SPD | 1-100 | |
| 7 | FIRE | SPD | 1-100 | |
| 8 | FIREWORKS | SPD | 1-100 | |
| 9 | EXPLOSION | SPD | 1-100 | |
| 10 | WELDING | SPD | 1-100 | |
| 11 | SOS | SOS | CCT | 2800K-6500K |
How do you access and adjust Bluetooth settings on the GODOX ML60II BI?
Continuously press the DIM/MODE/ Bluetooth button to enter the Bluetooth settings. Rotate the DIM/MODE/ Bluetooth button to select Bluetooth Off (OFF)/Bluetooth On (ON)/Bluetooth Reset (RESET).
What happens when Bluetooth is Off on the GODOX ML60II BI?
After Bluetooth is turned off, the “Godox Light” app cannot connect to the light body.
What happens when Bluetooth is On on the GODOX ML60II BI?
After Bluetooth is turned on, you can use the “Godox Light” app to connect to the light body.
How do you perform a Bluetooth Reset on the GODOX ML60II BI?
Select Bluetooth Reset (RESET), then press the DIM/MODE/ Bluetooth button briefly to perform a Bluetooth reset. After the reset is complete, it will automatically return to the Bluetooth settings interface.
What should be noted when switching mobile devices to control the GODOX ML60II BI via Bluetooth?
The first mobile device (phone or tablet) can directly control the light body using the app. When switching to another mobile device, the light body needs to be Bluetooth reset before the app can be used. The app needs to be upgraded to version 3.0 or above.
How does the GODOX ML60II BI indicate a low battery?
When the battery level is below one green bar, the display screen will automatically show a low battery symbol.
How does the GODOX ML60II BI indicate high lamp bead temperature?
When the light body display screen shows a thermometer icon, it indicates that the lamp bead temperature is too high. It is recommended to pause usage until the display screen no longer shows the thermometer icon, and then you can resume using the light.
What happens if the GODOX ML60II BI’s light body temperature is too high?
When the light body display screen shows a blinking thermometer icon, it indicates that the light body temperature is too high. The light body will automatically activate the usage restriction function. Once the lamp bead temperature returns to normal, the restriction will be automatically lifted, and you can adjust the brightness by rotating the DIM dial.
What is the photometric data for the GODOX ML60II BI?
The photometric data for the GODOX ML60II BI is as follows. The data is not absolute values but averages. All tests were conducted at 100% brightness of the light body. The mentioned reflector is included as a standard accessory.
| CCT | TestCondition | Unit | 1m | 2m | 3m |
|---|---|---|---|---|---|
| 2800K | Bare Light | lux | ≈2080 | ≈584 | ≈309 |
| fc | ≈194 | ≈54 | ≈29 | ||
| With Reflector | lux | ≈18500 | ≈4630 | ≈2090 | |
| fc | ≈1720 | ≈430 | ≈194 | ||
| 3200K | Bare Light | lux | ≈2200 | ≈615 | ≈316 |
| fc | ≈204 | ≈57 | ≈29 | ||
| With Reflector | lux | ≈19400 | ≈4900 | ≈2190 | |
| fc | ≈1800 | ≈455 | ≈204 | ||
| 4300K | Bare Light | lux | ≈2400 | ≈671 | ≈346 |
| fc | ≈223 | ≈62 | ≈32 | ||
| With Reflector | lux | ≈21400 | ≈5300 | ≈2390 | |
| fc | ≈1980 | ≈492 | ≈222 | ||
| 5600K | Bare Light | lux | ≈2530 | ≈717 | ≈364 |
| fc | ≈235 | ≈67 | ≈34 | ||
| With Reflector | lux | ≈22500 | ≈5620 | ≈2540 | |
| fc | ≈2090 | ≈522 | ≈236 | ||
| 6500K | Bare Light | lux | ≈2610 | ≈735 | ≈376 |
| fc | ≈242 | ≈68 | ≈35 | ||
| With Reflector | lux | ≈23300 | ≈5780 | ≈2630 | |
| fc | ≈2170 | ≈54 | ≈244 |
What are the technical specifications of the GODOX ML60II BI?
The technical specifications of the GODOX ML60II BI are:
| Model | ML60II Bi |
|---|---|
| Power Supply | 20V-3.5A |
| Input Power | Max. ≈70W |
| Brightness Range | 0%-100% |
| CRI | Average≥96 |
| TLCI | Average≥97 |
| CCT | 2800-6500K |
| FX Type | 11 |
| Bluetooth Control Distance | Max. 30m |
| Working Environment Temperature | -10℃~+40℃ |
| Light Body Dimension | 3.46″*3.62″*4.38″ |
| Net Weight (Lamp Head Protective Cover Included)≈ | ≈526g |
Specifications and data may subject to changes without notice.
CLICK HERE TO DOWNLOAD GODOX ML60II BI (02) PDF DOCUMENT