FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF DOCUMENT.
FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF USER GUIDE.
FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF USER MANUAL.
FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF OWNER GUIDE.
FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF OWNER MANUAL.
FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF REFERENCE GUIDE.
FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF REFERENCE MANUAL.
FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH EXTREME 5120-24XT-4Y (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD EXTREME 5120-24XT-4Y (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What tools are necessary for installing the EXTREME 5120-24XT-4Y?
The necessary tools for installing the EXTREME 5120-24XT-4Y are:
1. #2 Phillips screwdriver (a magnetic screwdriver is recommended)
2. ESD-protective wrist strap
What are the site requirements for installing the EXTREME 5120-24XT-4Y?
The installation site for the EXTREME 5120-24XT-4Y must meet the following requirements:
• Appropriately grounded power receptacles located within 1.8 m (6 ft.)
• A readily accessible device for disconnecting power, such as a breaker or master switch
• Network cabling within reach
• Ensure that the vent openings on the front panel and the rear fan modules are not blocked for proper ventilation
• Temperature between 0°C (32°F) and 50°C (122°F) – or as noted in “Operating Conditions” – with fluctuations of less than 10°C (18°F) per hour.
What components are included in the box with the EXTREME 5120-24XT-4Y?
After removing the packing material, verify that all of the following components are included:
1. Switch
2. Quick reference guide
3. Accessory box
4. Rack mount ears (2), accessory bag: Rail screws (12), rack screws (6), rack nuts (6)
Note: Console cables can be ordered separately.
How do I install the EXTREME 5120-24XT-4Y in a two-post rack?
You can install the EXTREME 5120-24XT-4Y in a standard 19-inch equipment rack. The switch can be installed in a two-post rack or a four-post rack using just the two front posts for forward mounting or two back posts for rear mounting.
This procedure uses a two-post mounting kit, which accommodates rack posts 3 inches or 6 inches wide. Rack ears can support both flush- and mid-mounting.
1. Attach a mounting bracket to each side of the switch. You can attach the brackets at the front of the switch (flush-mount), at the middle of the switch (mid-mount), or at the rear of the switch for rear mounting.
2. Secure the brackets to the rack posts using rack-mounting screws and nuts that are appropriate for the rack (provided). The switch can be mounted to the two front posts or the two rear posts as shown.
How do I connect the EXTREME 5120-24XT-4Y to a power source?
The EXTREME 5120-24XT-4Y runs on AC power. To connect the switch to a primary power source, do the following:
1. Connect the AC power cord to the AC power input socket on the power supply and an AC power outlet.
2. When power is connected, verify that the switch’s PWR LED turns green. If the PWR LED does not turn green, refer to the Extreme 5120 Hardware Installation Guide for troubleshooting information.
Note: Installing the system as described meets the protective earth grounding requirements of the National Electrical Code (NEC) UL 62368-1 and IEC 62368-1 standards. However, in some cases, it may be necessary to use an alternative grounding method. In these cases, a 14 AWG wire can be connected between the grounding lug on the chassis and a nearby building ground point.
What is the first step after powering on the EXTREME 5120-24XT-4Y?
Upgrade to a generally available (GA) version of the software before you use the EXTREME 5120-24XT-4Y. Switch Engine is the default operating system (OS) for the 5120 Series. To connect the switch to the network, upgrade it, and configure it for use, follow the steps in the Extreme 5120 Hardware Installation Guide.
What are the main components on the front and rear panels of the EXTREME 5120-24XT-4Y series switches?
Front Panel Components:
1. 1Gb/10Gb SFP+ ports (1Gb/10GBase-T non-PoE ports for 5120-24XT-4Y)
2. 10Gb/25Gb SFP28 ports
3. Micro-B USB serial console port
4. System LEDs
5. Mode button
6. USB Type A port
7. RJ-45 serial console port
8. 100/1000BASE-T out-of-band management port
9. 100Gb QSFP28 uplink ports
Rear Panel Components:
1. Modular AC power supplies
2. Grounding lug
3. Fan modules
4. Filler panels
What are the operating conditions for the EXTREME 5120-24XT-4Y?
Operating Temperature:
0°C (32°F) to 50°C (122°F) up to 3000 m (10,000 ft), front-to-back and back-to-front airflow
One fan failure (for model 5120-24XT-4Y):
0°C (32°F) to 50°C (122°F) up to 3000 m (10,000 ft), front-to-back and back-to-front airflow
Storage Temperature:
-40°C to 70°C (-40°F to 158°F)
Operating Relative Humidity:
5% to 95% (non-condensing)
What are the specific interfaces for the EXTREME 5120-24XT-4Y?
The EXTREME 5120-24XT-4Y (base model) is a stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots.
Each Extreme 5120 Series switch, including this model, also includes a Micro-B USB serial console port, an RJ-45 serial console port, a 100/1000BASE-T out-of-band management port, and a USB Type A storage port.
What are the interfaces for the different models in the Extreme 5120 series?
| Model | Description |
|---|---|
| 5120-44X-4Y-2C (base) | Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 empty fan slots, and 2 empty modular power supply unit slots. |
| 5120-44X-4Y-2C-AC-F | Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. |
| 5120-44X-4Y-2C-AC-R | Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow. |
| 5120-44X-4Y-2C-TAA (base) | Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant. |
| 5120-44X-4Y-2C-AC-F-TAA | Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant. |
| 5120-24X-4Y (base) | Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. |
| 5120-24X-4Y-AC-F | Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. |
| 5120-24X-4Y-AC-R | Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow. |
| 5120-24X-4Y-TAA (base) | Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant. |
| 5120-24X-4Y-AC-F-TAA | Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant. |
| 5120-24XT-4Y (base) | Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. |
| 5120-24XT-4Y-AC-F | Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. |
| 5120-24XT-4Y-AC-R | Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow. |
| 5120-24XT-4Y-TAA (base) | Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant. |
| 5120-24XT-4Y-AC-F-TAA | Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant. |
What are the compatible power supply and fan options for the EXTREME 5120-24XT-4Y?
| Part Number | Description |
|---|---|
| XN-ACPWR-550W-FB-A | 550W AC power supply with front-to-back airflow for 5120 Series switches. |
| XN-ACPWR-550W-BF-A | 550W AC power supply with back-to-front airflow for 5120 Series switches. |
| XN-FAN-005-F | Fan module with front-to-back airflow for 5120 Series switches. |
| XN-FAN-005-R | Fan module with back-to-front airflow for 5120 Series switches. |
What are the power specifications for the EXTREME 5120-24XT-4Y?
| AC Input | 100-120/200-240 VAC, 50-60 Hz, 2.5/1.2 A Max. for each PSU |
What rack-mount kits are available for the EXTREME 5120-24XT-4Y?
| Part Number | Description |
|---|---|
| XN-2P-RMKIT-014 | Two-post rack mount kit for 5120 Series switches for use with two- or four-post racks. |
What important safety notices should I be aware of when handling the EXTREME 5120-24XT-4Y?
Electrical Hazard: Only qualified instructed or skilled personnel should perform installation, repair, or disassembly procedures.
Power Disconnection: Extreme Networks power supplies do not have switches for turning the unit on and off. Before servicing, disconnect all power cords to remove power from the device. Make sure that these connections are easily accessible.
Installation Location: This equipment is designed for installation in restricted access locations and suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75, not suitable for use in locations where children are likely to be present.
Circuit Breaker: A dedicated Listed circuit breaker rated at 15A is to be used for each power supply connection.
Rack Stability: Before mounting the device, ensure that the rack can support it without compromising stability. Otherwise, personal injury or equipment damage may result.
ESD: Follow appropriate ESD procedures when unpacking and handling the switch. These include unpacking the switch in an ESD-safe environment and wearing appropriate ESD protective gear, such as ESD-safe footwear and ESD wrist straps where appropriate.
Indoor Use: This unit must be installed indoors. The unit, AC power adapter, and its cables are not designed for outdoor use.
Radiation Exposure: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
Laser Safety: Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. Use only UL/CSA, IEC/EN60825-1/-2 recognized pluggable modules.
Shock Hazard: Disconnect all power inputs before servicing.
What should I know about the battery inside the EXTREME 5120-24XT-4Y?
The EXTREME 5120-24XT-4Y contains a battery used to maintain product information. If the battery should need replacement it must be replaced by Service Personnel. There is a risk of explosion if the battery is replaced by an incorrect type. Dispose of the expended battery in accordance with local disposal regulations.
How should the EXTREME 5120-24XT-4Y be disposed of?
In accordance with Directive 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE):
1. The crossed-out wheeled bin symbol indicates that separate collection of electrical and electronic equipment is required.
2. When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste. It must be collected and treated separately.
3. It has been determined by the European Parliament that there are potential negative effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment.
4. It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated.
What regulatory and compliance information applies to the EXTREME 5120-24XT-4Y?
Federal Communications Commission (FCC) Notice: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment is a class A digital device.
Industry Canada Notice: CAN ICES-3 (A)/NMB-3(A). This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Class A ITE Notice: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.
Electromagnetic Compatibility (EMC): This product complies with FCC 47 CFR Part 15 Subpart B Class A (US), ICES-003 (Canada), EN 55032 (ITE Emissions), EN 55035 (ITE Immunity), and others.
Product Safety: This product complies with international safety standards including UL 62368-1, CAN/CSA C22.2 No. 62368-1-19, and IEC 62368-1.
Optical Module Compliance: Pluggable optical modules and direct-attach cables meet requirements for UL and/or CSA registration, Class 1 or Class 1M Laser Product standards, and IEC/EN 60825-1, IEC/EN 60825-2 or later European Standards.