EXTREME 5120-24X-4Y (01) Image

FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF DOCUMENT.
FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF USER GUIDE.
FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF USER MANUAL.
FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF OWNER GUIDE.
FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF OWNER MANUAL.
FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF REFERENCE GUIDE.
FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF REFERENCE MANUAL.
FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH EXTREME 5120-24X-4Y (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD EXTREME 5120-24X-4Y (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What tools are necessary for the installation of the EXTREME 5120-24X-4Y?

The following tools are needed to install the EXTREME 5120-24X-4Y:

1. #2 Phillips screwdriver (magnetic screwdriver recommended)

2. ESD-protective wrist strap


What are the installation site requirements for the EXTREME 5120-24X-4Y?

The installation site for the EXTREME 5120-24X-4Y must meet the following requirements:

• Appropriately grounded power receptacles located within 1.8 m (6 ft.)

• A readily accessible device for disconnecting power, such as a breaker or master switch

• Network cabling within reach

• Ensure that the vent openings on the front panel and the rear fan modules are not blocked for proper ventilation

• Temperature between 0°C (32°F) and 50°C (122°F) – or as noted in “Operating Conditions” – with fluctuations of less than 10°C (18°F) per hour.


What components are included when I unpack the EXTREME 5120-24X-4Y?

After removing the packing material, verify that all of the following components are included:

1. Switch

2. Quick reference guide

3. Accessory box

4. Rack mount ears (2), accessory bag: Rail screws (12), rack screws (6), rack nuts (6)


How do I install the EXTREME 5120-24X-4Y in a two-post rack?

You can install the EXTREME 5120-24X-4Y switch in a standard 19-inch equipment rack. The switch can be installed in a two-post rack, or in a four-post rack using just the two front or two back posts. The rack mount kit supports flush-mounting and mid-mounting.

This procedure uses a two-post mounting kit, which accommodates rack posts 3 inches or 6 inches wide.

1. Attach a mounting bracket to each side of the switch. You can attach the brackets at the front of the switch (flush-mount), at the middle of the switch (mid-mount), or at the rear of the switch.

2. Secure the brackets to the rack posts using rack-mounting screws and nuts that are appropriate for the rack (provided). The switch can be mounted to the two front posts or the two rear posts as shown.


How do I connect the EXTREME 5120-24X-4Y to a power source?

The EXTREME 5120-24X-4Y switch runs on AC power. To attach the switch to a power source, do the following:

1. Connect the AC power cord to the AC power input socket on the power supply and an AC power outlet.

2. When power is connected, verify that the switch’s PWR LED turns green. If the PWR LED does not turn green, refer to the Extreme 5120 Hardware Installation Guide for troubleshooting information.

Note: Installing the system as described meets the protective earth grounding requirements of the National Electrical Code (NEC) UL 62368-1 and IEC 62368-1 standards. However, in some cases, it may be necessary to use an alternative grounding method. In these cases, a 14 AWG wire can be connected between the grounding lug on the chassis and a nearby building ground point.


What is the initial software step after powering on the EXTREME 5120-24X-4Y?

Upgrade to a generally available (GA) version of the software before you use this unit. Switch Engine is the default operating system (OS) for the 5120 Series. To connect the switch to the network, upgrade it, and configure it for use, follow the steps in the Extreme 5120 Hardware Installation Guide.


What are the key safety notices and precautions for the EXTREME 5120-24X-4Y?

Electrical Hazard: Only qualified instructed or skilled personnel should perform installation, repair, or disassembly procedures.

Warning: Extreme Networks power supplies do not have switches for turning the unit on and off. Before servicing, disconnect all power cords to remove power from the device. Make sure that these connections are easily accessible.

Warning: This equipment is designed for installation in restricted access locations and suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75, not suitable for use in locations where children are likely to be present.

Warning: A dedicated Listed circuit breaker rated at 15A is to be used for each power supply connection.

Caution: Before mounting the device, ensure that the rack can support it without compromising stability. Otherwise, personal injury or equipment damage may result.

Caution: Follow appropriate ESD procedures when unpacking and handling the switch. These include unpacking the switch in an ESD-safe environment and wearing appropriate ESD protective gear, such as ESD-safe footwear and ESD wrist straps where appropriate.

Warning: This unit must be installed indoors. The unit, AC power adapter, and its cables are not designed for outdoor use.

Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Warning: Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. Use only UL/CSA, IEC/EN60825-1/-2 recognized pluggable modules.

Caution! Shock hazard! Disconnect all power inputs before servicing.

Battery Notice: This product contains a battery used to maintain product information. If the battery should need replacement it must be replaced by Service Personnel. Risk of explosion if battery is replaced by an incorrect type. Dispose of expended battery in accordance with local disposal regulations.


What are the hardware components on the front and rear panels of the EXTREME 5120-24X-4Y series switches?

Front Panel Components:

1. 1Gb/10Gb SFP+ ports (1Gb/10GBase-T non-PoE ports for 5120-24XT-4Y)

2. 10Gb/25Gb SFP28 ports

3. Micro-B USB serial console port

4. System LEDS

5. Mode button

6. USB Type A port

7. RJ-45 serial console port

8. 100/1000BASE-T out-of-band management port

9. 100Gb QSFP28 uplink ports

Rear Panel Components:

1. Modular AC power supplies

2. Grounding lug

3. Fan modules

4. Filler panels


What are the operating conditions for the EXTREME 5120-24X-4Y?

Operating Temperature:

0°C (32°F) to 50°C (122°F) up to 3000 m (10,000 ft), front-to-back and back-to-front airflow

One fan failure (5120-24X-4Y model):

• 0°C (32°F) to 50°C (122°F) at sea level and at 3000 m (10,000 ft), front-to-back airflow

• 0°C (32°F) to 50°C (122°F) at sea level and 45°C (113°F) at 3000 m (10,000 ft), back-to-front airflow

Storage Temperature:

-40°C to 70°C (-40°F to 158°F)

Operating Relative Humidity:

5% to 95% (non-condensing)


What interfaces are available on the EXTREME 5120-24X-4Y series switches?

Each EXTREME 5120-24X-4Y Series switch includes a Micro-B USB serial console port, an RJ-45 serial console port, a 100/1000BASE-T out-of-band management port, and a USB Type A storage port. The switches are pre-loaded with the Switch Engine OS.

The following table lists the specific interfaces for each switch model:

Model Interfaces
5120-44X-4Y-2C (base) Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 empty fan slots, and 2 empty modular power supply unit slots.
5120-44X-4Y-2C-AC-F Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow.
5120-44X-4Y-2C-AC-R Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow.
5120-44X-4Y-2C-TAA (base) Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant.
5120-44X-4Y-2C-AC-F-TAA Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant.
5120-24X-4Y (base) Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots.
5120-24X-4Y-AC-F Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow.
5120-24X-4Y-AC-R Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow.
5120-24X-4Y-TAA (base) Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant.
5120-24X-4Y-AC-F-TAA Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant.
5120-24XT-4Y (base) Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots.
5120-24XT-4Y-AC-F Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow.
5120-24XT-4Y-AC-R Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow.
5120-24XT-4Y-TAA (base) Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant.
5120-24XT-4Y-AC-F-TAA Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant.

What are the power supply and fan options for the EXTREME 5120-24X-4Y series?

Model Description
XN-ACPWR-550W-FB-A 550W AC power supply with front-to-back airflow for 5120 Series switches.
XN-ACPWR-550W-BF-A 550W AC power supply with back-to-front airflow for 5120 Series switches.
XN-FAN-005-F Fan module with front-to-back airflow for 5120 Series switches.
XN-FAN-005-R Fan module with back-to-front airflow for 5120 Series switches.

What is the available rack-mount kit for the EXTREME 5120-24X-4Y series?

Part Number Description
XN-2P-RMKIT-014 Two-post rack mount kit for 5120 Series switches for use with two- or four-post racks.

What are the power specifications for the EXTREME 5120-24X-4Y?

AC Input: 100-120/200-240 VAC, 50-60 Hz, 2.5/1.2 A Max. for each PSU

What is the Federal Communications Commission (FCC) Notice for the EXTREME 5120-24X-4Y?

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.

WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.


What is the Industry Canada Notice for the EXTREME 5120-24X-4Y?

CAN ICES-3 (A)/NMB-3(A)

This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.


What is the Class A ITE warning for the EXTREME 5120-24X-4Y?

WARNING: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.


How should the EXTREME 5120-24X-4Y be disposed of at the end of its life?

In accordance with Directive 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE):

1. The symbol on the product indicates that separate collection of electrical and electronic equipment is required.

2. When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste. It must be collected and treated separately.

3. It has been determined by the European Parliament that there are potential negative effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment.

4. It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated.