EXTREME 5120-24X-4Y-AC-F-TAA (01) Image

FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF DOCUMENT.
FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF USER GUIDE.
FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF USER MANUAL.
FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF OWNER GUIDE.
FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF OWNER MANUAL.
FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF REFERENCE GUIDE.
FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF REFERENCE MANUAL.
FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What tools are necessary to install the EXTREME 5120-24X-4Y-AC-F-TAA?

The necessary tools for installation are:

1. #2 Phillips screwdriver (a magnetic screwdriver is recommended)

2. ESD-protective wrist strap


What are the site requirements for installing the EXTREME 5120-24X-4Y-AC-F-TAA?

The installation site must meet the following requirements:

Appropriately grounded power receptacles located within 1.8 m (6 ft.)

A readily accessible device for disconnecting power, such as a breaker or master switch

Network cabling within reach

Ensure that the vent openings on the front panel and the rear fan modules are not blocked for proper ventilation

Temperature between 0°C (32°F) and 50°C (122°F), or as noted in “Operating Conditions”, with fluctuations of less than 10°C (18°F) per hour.


What components are included when I unpack the box for the EXTREME 5120-24X-4Y-AC-F-TAA?

After removing the packing material, verify that all of the following components are included:

1. Switch

2. Quick reference guide

3. Accessory box

4. Rack mount ears (2), accessory bag: Rail screws (12), rack screws (6), rack nuts (6)

Console cables can be ordered separately.


How do I install the EXTREME 5120-24X-4Y-AC-F-TAA in a two-post rack?

The EXTREME 5120-24X-4Y-AC-F-TAA can be installed in a standard 19-inch equipment rack. This procedure uses a two-post mounting kit, which accommodates rack posts 3 inches or 6 inches wide. Rack ears can support both flush- and mid-mounting.

1. Attach a mounting bracket to each side of the switch. You can attach the brackets at the front of the switch or at the middle of the switch.

2. Secure the brackets to the rack posts using rack-mounting screws and nuts that are appropriate for the rack (provided). The switch can be mounted to the two front posts or the two rear posts as shown.


How do I connect the EXTREME 5120-24X-4Y-AC-F-TAA to a power source?

The EXTREME 5120-24X-4Y-AC-F-TAA runs on AC power. To attach the switch to a power source, do the following:

1. Connect the AC power cord to the AC power input socket on the power supply and an AC power outlet.

2. When power is connected, verify that the switch’s PWR LED turns green. If the PWR LED does not turn green, refer to the Extreme 5120 Hardware Installation Guide for troubleshooting information.

Note: In some cases, it may be necessary to use an alternative grounding method. In these cases, a 14 AWG wire can be connected between the grounding lug on the chassis and a nearby building ground point.


What is the initial software configuration step for the EXTREME 5120-24X-4Y-AC-F-TAA?

Upgrade to a generally available (GA) version of the software before you use the unit. Switch Engine is the default operating system (OS) for the 5120 Series. To connect the switch to the network, upgrade it, and configure it for use, follow the steps in the Extreme 5120 Hardware Installation Guide.


What are the hardware components on the front and rear panels of the EXTREME 5120-24X-4Y-AC-F-TAA and similar models?

The hardware components are identified as follows:

Front Panel Components:

1. 1Gb/10Gb SFP+ ports (1Gb/10GBase-T non-PoE ports for 5120-24XT-4Y)

2. 10Gb/25Gb SFP28 ports

3. Micro-B USB serial console port

4. System LEDs

5. Mode button

6. USB Type A port

7. RJ-45 serial console port

8. 100/1000BASE-T out-of-band management port

9. 100Gb QSFP28 uplink ports

Rear Panel Components:

1. Modular AC power supplies

2. Grounding lug

3. Fan modules

4. Filler panels


What are the operating conditions for the EXTREME 5120-24X-4Y-AC-F-TAA?

Operating Temperature:

0°C (32°F) to 50°C (122°F) up to 3000 m (10,000 ft), front-to-back and back-to-front airflow

One fan failure:

5120-44X-4Y-2C

0°C (32°F) to 50°C (122°F) at sea level and 45°C (113°F) at 3000 m (10,000 ft), front-to-back airflow

0°C (32°F) to 45°C (113°F) at sea level and 40°C (104°F) at 3000 m (10,000 ft), back-to-front airflow

5120-24X-4Y

0°C (32°F) to 50°C (122°F) at sea level and at 3000 m (10,000 ft), front-to-back airflow

0°C (32°F) to 50°C (122°F) at sea level and 45°C (113°F) at 3000 m (10,000 ft), back-to-front airflow

5120-24XT-4Y

0°C (32°F) to 50°C (122°F) up to 3000 m (10,000 ft), front-to-back and back-to-front airflow

Storage Temperature:

-40°C to 70°C (-40°F to 158°F)

Operating Relative Humidity:

5% to 95% (non-condensing)


What are the specific interfaces for the EXTREME 5120-24X-4Y-AC-F-TAA and other models in the 5120 Series?

Each Extreme 5120 Series switch includes a Micro-B USB serial console port, an RJ-45 serial console port, a 100/1000BASE-T out-of-band management port, and a USB Type A storage port. 5120 Series switches are pre-loaded with the Switch Engine OS.

The following table lists the specific interfaces for each switch:

5120-44X-4Y-2C (base) Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 empty fan slots, and 2 empty modular power supply unit slots.
5120-44X-4Y-2C-AC-F Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow.
5120-44X-4Y-2C-AC-R Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow.
5120-44X-4Y-2C-TAA (base) Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant.
5120-44X-4Y-2C-AC-F-TAA Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant.
5120-24X-4Y (base) Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots.
5120-24X-4Y-AC-F Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow.
5120-24X-4Y-AC-R Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow.
5120-24X-4Y-TAA (base) Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant.
5120-24X-4Y-AC-F-TAA Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant.
5120-24XT-4Y (base) Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots.
5120-24XT-4Y-AC-F Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow.
5120-24XT-4Y-AC-R Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow.
5120-24XT-4Y-TAA (base) Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant.
5120-24XT-4Y-AC-F-TAA Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant.

What are the power supply and fan options for the EXTREME 5120-24X-4Y-AC-F-TAA?

XN-ACPWR-550W-FB-A 550W AC power supply with front-to-back airflow for 5120 Series switches.
XN-ACPWR-550W-BF-A 550W AC power supply with back-to-front airflow for 5120 Series switches.
XN-FAN-005-F Fan module with front-to-back airflow for 5120 Series switches.
XN-FAN-005-R Fan module with back-to-front airflow for 5120 Series switches.

What are the power specifications for the EXTREME 5120-24X-4Y-AC-F-TAA?

AC Input: 100-120/200-240 VAC, 50-60 Hz, 2.5/1.2 A Max. for each PSU

Are there available rack-mount kits for the EXTREME 5120-24X-4Y-AC-F-TAA?

XN-2P-RMKIT-014 Two-post rack mount kit for 5120 Series switches for use with two- or four-post racks.

What safety notices and warnings should I be aware of when handling the EXTREME 5120-24X-4Y-AC-F-TAA?

Caution! Shock hazard! Disconnect all power inputs before servicing.

Electrical Hazard: Only qualified instructed or skilled personnel should perform installation, repair, or disassembly procedures.

Warning: Extreme Networks power supplies do not have switches for turning the unit on and off. Before servicing, disconnect all power cords to remove power from the device. Make sure that these connections are easily accessible.

Warning: This equipment is designed for installation in restricted access locations and suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical Code and NFPA 75, not suitable for use in locations where children are likely to be present.

Warning: A dedicated Listed circuit breaker rated at 15A is to be used for each power supply connection.

Caution: Before mounting the device, ensure that the rack can support it without compromising stability. Otherwise, personal injury or equipment damage may result.

Caution: Follow appropriate ESD procedures when unpacking and handling the switch. These include unpacking the switch in an ESD-safe environment and wearing appropriate ESD protective gear, such as ESD-safe footwear and ESD wrist straps where appropriate.

Warning: This unit must be installed indoors. The unit, AC power adapter, and its cables are not designed for outdoor use.

Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Warning: Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. Use only UL/CSA, IEC/EN60825-1/-2 recognized pluggable modules.

Warning (Battery): This product contains a battery used to maintain product information. If the battery should need replacement it must be replaced by Service Personnel. Risk of explosion if battery is replaced by an incorrect type. Dispose of expended battery in accordance with local disposal regulations.


What is the Federal Communications Commission (FCC) notice for the EXTREME 5120-24X-4Y-AC-F-TAA?

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.

WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.


How should the EXTREME 5120-24X-4Y-AC-F-TAA be disposed of at the end of its life?

In accordance with Directive 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE):

1. The WEEE symbol indicates that separate collection of electrical and electronic equipment is required.

2. When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste. It must be collected and treated separately.

3. It has been determined by the European Parliament that there are potential negative effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment.

4. It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated.


CLICK HERE TO DOWNLOAD EXTREME 5120-24X-4Y-AC-F-TAA (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.