What are the important safety instructions for the ELECTRO-VOICE CPS 1?
Please adhere to the following safety instructions when using your amplifier:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a damp cloth.
7. Do not block any of the ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
9. Only use attachments/accessories specified by the manufacturer.
10. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
What does the LIMIT indicator on the ELECTRO-VOICE CPS 1 mean?
What does the SIGNAL indicator on the ELECTRO-VOICE CPS 1 signify?
What should I do if the POWER ON indicator on my ELECTRO-VOICE CPS 1 does not light up?
What does the PROTECT indicator on the ELECTRO-VOICE CPS 1 mean?
What is the function of the POWER switch on the ELECTRO-VOICE CPS 1?
How do I connect audio sources to the inputs of the ELECTRO-VOICE CPS 1?
XLR-type input connectors pin-assignment:
PIN 1: SHIELD
PIN 2: a, +
PIN 3: b, –
The input sensitivity is factory set to 1Vrms.
How should the LEVEL CONTROLS on the ELECTRO-VOICE CPS 1 be set?
What are the INPUT ROUTING options on the ELECTRO-VOICE CPS 1?
PARALLEL MONAURAL: Setting the selector switch to the PARALLEL/MONO position puts the channel A and channel B inputs in an electrically direct parallel configuration. This leaves you with the opportunity to individually control the channels’ level settings using the output controls A and B.
DUAL STEREO: When the selector switch is set to its DUAL/STEREO position, both channels are amplified separately.
How do I connect loudspeakers to the POWER AMPLIFIER OUTPUTS of the ELECTRO-VOICE CPS 1?
How do I configure and use BRIDGED MODE on the ELECTRO-VOICE CPS 1?
To use Bridged Mode:
1. Engage the bridged mode switch on the rear panel.
2. You must use the channel A input. The channel B input will be out of function.
In this mode, the signal is internally inverted and fed to the channel B power amp. The two amplifiers (A+B) are used in a push-pull operation, providing double the output voltage at the BRIDGED-OUT connector. The minimal load for bridged mode is 4 ohms. Bridged mode operation with loads of 2 ohms is not admissible.
What is the purpose of the GROUND-LIFT switch on the ELECTRO-VOICE CPS 1?
GROUNDED position: This is the recommended setting when the power amplifier is installed in a 19″ rack system and operated with other equipment.
UNGROUNDED position: This setting is recommended if the power amplifier is used with appliances that are connected to different ground potentials.
What protection features are built into the ELECTRO-VOICE CPS 1?
What are the technical specifications for the ELECTRO-VOICE CPS 1?
Amplifier at rated conditions, both channels driven with 8 ohms loads, unless otherwise specified.
| CPS1 | |||
| Load Impedance | 8 Ω | 4 Ω | 2 Ω |
| Maximum Midband Output Power THD=1%, 1kHz | 280W | 450W | 650W |
| Rated Output Power THD < 0, 2%, 20Hz ... 20kHz | 230W | 350W | 450W |
| Maximum Bridged Output Power THD=1%, 1kHz | 900W | 1300W | — |
| Maximum RMS Voltage Swing THD=1%, 1kHz | 56V | ||
| Voltage Gain at 1 kHz | 32,5dB | ||
| Slew Rate at 1 kHz | 25V/μs | ||
| Power Consumption at 1/8 maximum output power @ 4 Ω | 690W | ||
| Input Sensitivity at rated output power @ 8 Ω, 1 kHz | 1Vrms | ||
| THD at rated output power, MBW=80kHz, 1 kHz | < 0.05 % | ||
| IMD-SMPTE 60 Hz, 7 kHz | < 0.08 % | ||
| DIM30 3.15kHz, 15 kHz | < 0.03 % | ||
| Crosstalk ref. 1kHz, at rated output power | <-80 dB | ||
| Frequency Response -1dB, ref. 1 kHz | 10Hz … 45kHz | ||
| Power Bandwidth THD=1%, ref. 1kHz, half power @ 4 Ω | 10Hz … 50kHz | ||
| Input Impedance 20Hz … 20 kHz, balanced | 20kΩ | ||
| Damping Factor at 100Hz / 1kHz | >300 / >200 | ||
| Signal to Noise Ratio A-weighted | 105dB | ||
| Power Requirements | 120V/230V/240V, 50Hz … 60Hz | ||
| Protection | Audio limiters, High temperature, DC, HF, Back-EMF, Peak current limiters, Inrush current limiters, Turn-on delay | ||
| Cooling | Front-to-Rear, 3-stage-fans | ||
| Safety Class | I | ||
| Dimensions (W x H x D), mm | 483 x 132.5 x 385.5 | ||
| Weight | 15kg | ||
What are the physical dimensions of the ELECTRO-VOICE CPS 1?
- Width: 483 mm
- Height: 132.5 mm
- Depth: 385.5 mm (386 mm from front to back, 397 mm including handles)