What are the important safety instructions for using the ELECTRO-VOICE CPS 2?
To ensure safe operation of your ELECTRO-VOICE CPS 2, please follow these instructions:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a damp cloth.
7. Do not block any of the ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
9. Only use attachments/accessories specified by the manufacturer.
10. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
What are the important service instructions for qualified personnel working on the ELECTRO-VOICE CPS 2?
CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
1. Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 – 94 have to be obeyed when servicing the appliance.
2. Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains.
3. Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.
4. The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times.
5. Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.
6. Altering the circuitry without prior consent or advice is not legitimate.
7. Any work security regulations that are applicable at the location where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself.
8. All instructions concerning the handling of MOS – circuits have to be observed.
Note: A safety component has to be replaced with an original part only.
What protection features are built into the ELECTRO-VOICE CPS 2 amplifier?
What does the LIMIT indicator on the front panel of the ELECTRO-VOICE CPS 2 mean?
What does the SIGNAL indicator on the ELECTRO-VOICE CPS 2 signify?
Why is the POWER ON indicator on my ELECTRO-VOICE CPS 2 not lit after I’ve turned it on?
What should I do if the PROTECT indicator on my ELECTRO-VOICE CPS 2 lights up?
How do I connect audio inputs to the ELECTRO-VOICE CPS 2?
PIN 1: SHIELD
PIN 2: a, +
PIN 3: b, –
The input sensitivity is factory set to 1Vrms.How should I set the LEVEL CONTROLS on the rear panel of the ELECTRO-VOICE CPS 2?
What are the INPUT ROUTING options on the ELECTRO-VOICE CPS 2?
DUAL STEREO: When the selector switch is set to its DUAL/STEREO position, both channels are amplified separately.
PARALLEL MONAURAL: Setting the selector switch to the PARALLEL/MONO position puts the channel A and channel B inputs in an electrically direct parallel configuration. This allows you to individually control the channels’ level settings by using the output controls A and B.
How do I connect speakers to the POWER AMPLIFIER OUTPUTS on the ELECTRO-VOICE CPS 2?
How do I operate the ELECTRO-VOICE CPS 2 in BRIDGED MODE?
1. Engage the bridged mode switch on the rear panel.
2. You must use the channel A input. The channel B input will be out of function.
The signal gets internally inverted and fed to the channel B power amp. The two amplifiers A+B are then used in a push-pull operation, providing double the output voltage at the BRIDGED-OUT connector. Bridged mode operation with loads of 2 ohms is not admissible.
When should I use the GROUND-LIFT SWITCH on the ELECTRO-VOICE CPS 2?
GROUNDED position: This is the recommended setting whenever the power amplifier is installed in a 19″ rack system being operated together with other equipment.
UNGROUNDED position: This setting is recommended in case the power amplifier is used together with appliances that are connected to different ground potentials.
What are the technical specifications for the ELECTRO-VOICE CPS 2?
The following are the technical specifications for the ELECTRO-VOICE CPS 2 amplifier at rated conditions, with both channels driven with 8 ohms loads, unless otherwise specified.
| Specification | Value |
|---|---|
| Load Impedance | 8 Ω / 4 Ω / 2 Ω |
| Maximum Midband Output Power, THD=1%, 1kHz | 380W / 600W / 850W |
| Rated Output Power, THD < 0.2%, 20Hz ... 20kHz | 300W / 500W / 650W |
| Maximum Bridged Output Power, THD=1%, 1kHz | 1200W / 1700W |
| Maximum RMS Voltage Swing, THD=1%, 1kHz | 64V |
| Voltage Gain, at 1 kHz | 33,5dB |
| Slew Rate, at 1 kHz | 30V/µs |
| Power Consumption, at 1/8 maximum output power @ 4 Ω | 870W |
| Input Sensitivity, at rated output power @ 8 Ω, 1 kHz | 1Vrms |
| THD at rated output power, MBW=80kHz, 1 kHz | < 0.05 % |
| IMD-SMPTE, 60 Hz, 7 kHz | < 0.08 % |
| DIM30, 3.15kHz, 15 kHz | < 0.03 % |
| Crosstalk, ref. 1kHz, at rated output power | < -80 dB |
| Frequency Response, -1dB, ref. 1 kHz | 10Hz … 45kHz |
| Power Bandwidth, THD=1%, ref. 1kHz, half power @ 4 Ω | 10Hz … 50kHz |
| Input Impedance, 20Hz … 20 kHz, balanced | 20kΩ |
| Damping Factor, at 100Hz / 1kHz | >300 / >200 |
| Signal to Noise Ratio, A-weighted | 105dB |
| Power Requirements | 120V/230V/240V, 50Hz … 60Hz |
| Protection | Audio limiters, High temperature, DC, HF, Back-EMF, Peak current limiters, Inrush current limiters, Turn-on delay |
| Cooling | Front-to-Rear, 3-stage-fans |
| Safety Class | I |
| Dimensions (W x H x D), mm | 483 x 132.5 x 385.5 |
| Weight | 16kg |