Free English AIR INNOVATIONS MH-509 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD AIR INNOVATIONS MH-509 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What are the key safety instructions for using the AIR INNOVATIONS MH-509?
Prior to using the AIR INNOVATIONS MH-509, read through the instructions for complete use and keep in a safe place for later reference.
• WARNING: DO NOT use outdoors. Only use as intended and described in this manual.
• WARNING: DO NOT expose or immerse the Base in water or other liquids.
• WARNING: Keep cord away from heated surfaces and out of the way, where it cannot be stepped on or tripped over.
• WARNING: ALWAYS place humidifier on an elevated firm, flat, level surface where it’s not easily knocked over (e.g. on a table, chest, cabinet, etc.).
• WARNING: DO NOT place the appliance directly on the floor, next to a heating vent, under direct sunlight, high temperature areas, near computers or sensitive electronic equipment.
• WARNING: DO NOT place the appliance directly on wood furniture or other surfaces which could get damaged by water.
• WARNING: NEVER use in an environment where explosive gases are present.
• WARNING: NEVER drop or insert any object into any opening.
• WARNING: NEVER cover the appliance when it’s in operation.
• WARNING: To unplug turn controls to the “OFF” position, then remove the plug from the outlet. Ensure your hands are dry.
• WARNING: ALWAYS unplug and EMPTY the Water Tank when not in use for a long period of time.
• WARNING: ALWAYS turn off or unplug before removing, filling or emptying the Water Tank.
• WARNING: DO NOT wash, adjust or move without first unplugging the unit.
• WARNING: NEVER operate WITHOUT water in the tank.
• WARNING: DO NOT use hot water in the tank.
• WARNING: ONLY use water in the tank, never use any additive such as essential oils, eucalyptus, water conditioners, etc., in the water.
• WARNING: DO NOT move appliance with water inside the tank. In this case remove the Water Tank and empty the Water Reservoir prior to moving.
• WARNING: DO NOT direct the mist against a wall or other home appliance.
• WARNING: DO NOT pour water into the Base through Air Outlet during cleaning and filling.
• WARNING: DO NOT rinse Base under faucet.
• WARNING: NEVER scrape the Ultrasonic Nebulizer with a hard or sharp object.
How do I unpack the AIR INNOVATIONS MH-509?
1. Carefully remove the humidifier from the box by pulling the Base of the unit (Do not take the unit out of the box by pulling the Water Tank).
2. Remove the plastic bag from the humidifier.
*Follow directions to fill and operate the humidifier.
What are the technical specifications for the AIR INNOVATIONS MH-509?
| Product Model | Power Consumption | Current | Rating Voltage | Tank Capacity | Dimensions | Weight |
|---|---|---|---|---|---|---|
| MH-509 | 30W | 0.4A | 110-120V~60Hz | 5.2L / 1.36 Gallon | 9.75″W x 6.5″D x 13.5″H | 3.39 Lbs. |
What are the parts and contents of the AIR INNOVATIONS MH-509?
1. Rotating Mist Nozzle
2. Water Tank
3. Base
4. Control Panel
5. Ultrasonic Nebulizer
6. Air Outlet
7. Water Sensor
8. Water Reservoir
9. Cleaning Brush
10. Ceramic Filter
11. Tank Cap
12. Bottom Tank Handle
How do I fill the water tank on the AIR INNOVATIONS MH-509?
WARNING: Always unplug the unit before removing the Water Tank.
WARNING: DO NOT touch the water in the Base.
WARNING: NEVER fill the Water Tank from the top of the unit.
1. Remove Rotating Mist Nozzle prior to filling the Water Tank.
2. Turn the Water Tank upside down and remove the Tank Cap by turning it counter clockwise.
3. Filling the Water Tank: Use clean, cool, tap water. WARNING: DO NOT use extremely cold water, since it may temporarily reduce the mist output. WARNING: NEVER fill with hot/warm water or use additives as this could damage the unit and void the warranty. WARNING: If you have hard tap water STOP using tap water and use ONLY filtered, distilled, cold boiled or bottled water.
4. Replace the Tank Cap by firmly turning clockwise until tight. Turn the Water Tank upright and check the Tank Cap for leaks. If any water drips, remove the Tank Cap and retighten. WARNING: DO NOT place Water Tank on the humidifier Base if the cap is leaking.
5. Place the humidifier Water Tank on the Base, make sure to follow the shape of the Water Tank and the humidifier Base so that the tank sits level and flush to the Base. Ensure the tank is firmly seated.
6. Attach the Rotating Mist Nozzle to the top of the Water Tank for desired use as pictured.
How do I operate the AIR INNOVATIONS MH-509?
WARNING: DO NOT operate the humidifier without water in the tank.
WARNING: NEVER lift the tank off the Base while the unit is operating.
ON/OFF – Plug into a standard (120V AC) electrical outlet. The LED Display will turn on for 2 seconds then turn OFF. Press the ON/OFF button once and the “Operating” indicator will turn ON. Mist may not appear immediately; allow up to 15 minutes for the water in the tank to transfer to the Base.
Delay Start – The Delay Start feature allows you to program the unit to turn ON Automatically. To use, press the “Delay Start” button once; you will see “Delay Start” 01:00H illuminated on the display. This feature works in one hour increments and is programmable up to 24 hours. Simply keep pressing the Delay Start button until you get to your desired delay start time. Once you have reached the time the display will flash three times and then will start to countdown until the unit turns ON.
Auto-Off – The Auto-Off feature allows you to run the humidifier now and set it to turn Off at a specific time automatically (in 1 hour increments from 1-24 hours). To use – press the “Auto-Off” button once; you will see “Auto-Off” 01:00H illuminated on the display. This feature works in one hour increments and is programmable up to 24 hours. Simply keep pressing the Auto-Off button until you get to your desired Auto-Off time. Once you have reached the time the display will flash three times and then start to count down until the unit turns OFF. The display will start alternating between the current ambient humidity and the Auto-off Timer. NOTE: You can use the Delay Start and Auto-Off functions together on this fully programmable LED Display to program the humidifier to turn ON and turn OFF at your desired times.
Mist Output – When you turn the unit ON, it will default to the lowest mist setting. Pressing the “Mist” button each time will increase the output. Press once for Medium, twice for High, three times for Supreme. Pressing the Mist button a fourth time will bring the unit back to Low.
Humidistat – By using this feature the humidifier will automatically monitor and control the humidity level according to your desired setting. Once the desired humidity level is reached the mist will shut OFF until the humidity drops below the setting and then the mist will turn back ON automatically to maintain the humidity level desired. To set this feature press the “Humidistat” button to your desired setting. Settings range from 40%-95% RH (Relative Humidity) in 5% RH increments. A 40%-60% Relative Humidity is recommended. Once you set your desired humidity, the number will blink 3 times and then the display will revert back to the relative humidity. To view the set humidity level, press the Humidistat button once.
LED Dim – To turn OFF the LED Display, press the “LED DIM” button once. Press the “LED DIM”, or any other button on the control panel to turn the display back ON.
LOW Water – When the tank is out of water the “waterless” indicator will appear in the display, you will hear 3 beeps and the automatic safety shut-off will turn the Ultrasonic Nebulizer & unit OFF.
How do I perform weekly cleaning and care on the AIR INNOVATIONS MH-509?
WARNING: Before cleaning always turn power Off and unplug the unit from outlet.
WARNING: DO NOT rinse Base under faucet. To clean, wipe the Base with a paper towel.
WARNING: DO NOT use any solvents or aggressive cleaning agents. Keep water away from the Air Outlet. WARNING: DO NOT tamper with the Water Sensor.
About White Dust -Use of high-mineral content water may cause a white mineral residue to accumulate on room surfaces near the humidifier. The mineral residue is commonly referred to as “White Dust”. The higher the mineral content (the harder your water is), the greater the potential for White Dust. The White Dust is not caused by a defect in the humidifier, but is due only to minerals suspended in the water from your tap. WARNING: If you have hard tap water STOP using tap water and use ONLY filtered, distilled, cold boiled or bottled water to minimize the White Dust residue.
Tank Cleaning – Remove the Rotating Mist Nozzle from the top of the Water Tank then remove the Water Tank from the unit. Turn the tank upside down, unscrew the Tank Cap and drain any water from the tank. Wipe the tank with a soft damp cloth then rinse it with warm water inside and out.
Base Cleaning – Gently wipe the Base with a soft damp cloth.
White Dust Cleaning – If mineral deposits “White Dust” are evident around the Ultrasonic Nebulizer and Water Sensor, clean these surfaces with a soft, cloth and a small amount of undiluted white vinegar. If necessary, mix a solution of 50% white vinegar and 50% water and fill the Base with enough solution to cover the Ultrasonic Nebulizer. Allow it to soak for an hour and then use the provided brush to gently loosen buildup on the Ultrasonic Nebulizer. Put 1 cup of water in the Base and wipe clean with a soft cloth. WARNING: DO NOT rinse base under faucet.
Ceramic Water Filter Cleaning – Remove the Water Tank from the humidifier Base. Remove the Tank Cap and rinse Ceramic Filter thoroughly with tap water, then replace on Water Tank.
Surface Cleaning – Clean all surfaces of the unit with a clean damp soft cloth.
WARNING: When emptying the Water Reservoir on the Base, make sure that the water is poured away from the Air Outlet. If water is poured into the outlet it may damage the humidifier.
How should I store my AIR INNOVATIONS MH-509?
1. Follow all cleaning instructions prior to storage.
2. Dry all parts, including the inside of the Water Tank. WARNING: NEVER leave water inside the tank for several days.
3. Leave the Water Tank Cap partially loosened to prolong the life of the cap.
4. Preferably store in its original box, in a dry place away from high temperatures.
5. Follow all cleaning instructions after long periods of storage.
What should I do if my AIR INNOVATIONS MH-509 has a peculiar odor?
POSSIBLE CAUSES
a. If new unit
b. Dirty Water Tank or old water in tank
c. Minerals in well water or hard water
POSSIBLE SOLUTIONS
a. Rinse Water Tank and let air dry. Wipe Base with a soft damp cloth
b. Empty old water and clean Water Tank per instructions
c. Use filtered, distilled, cold boiled or bottled water
Why is the power light off on my AIR INNOVATIONS MH-509?
POSSIBLE CAUSES
a. Unit is not plugged in
b. No power at outlet
POSSIBLE SOLUTIONS
a. Plug in power cable
b. Check circuits, fuses, or try a different outlet
What should I do if my AIR INNOVATIONS MH-509 is producing white dust on the unit or nearby furniture?
POSSIBLE CAUSE
a. Hard water used
POSSIBLE SOLUTION
a. Use filtered, distilled, cold boiled or bottled water
What should I do if my AIR INNOVATIONS MH-509 has weak or no mist output?
POSSIBLE CAUSES
a. No water in tank
b. Unit is not level
c. White Dust on Ultrasonic Nebulizer and/or Water Sensor
d. Blower not operating
e. Water temperature is too low
f. Ultrasonic Nebulizer is not operating
POSSIBLE SOLUTIONS
a. Fill tank with water and wait 10 – 15 minutes
b. Place unit on level surface
c. Clean Humidifier per instructions
d. Ensure there is enough water in Base to activate water sensor
e. Set output to High and wait for 10 – 15 minutes
f. See Warranty
Why is condensation forming around my AIR INNOVATIONS MH-509 or on windows?
POSSIBLE CAUSES
a. Mist output is set too high for the room size
b. Direction of Rotating Mist Nozzle
POSSIBLE SOLUTIONS
a. Decrease the mist output
b. Change direction of the Rotating Mist Nozzle
Why is my AIR INNOVATIONS MH-509 leaking water?
POSSIBLE CAUSES
a. Tank Cap is not properly attached
b. Water Tank is not properly seated
c. Unit is not on level surface
POSSIBLE SOLUTIONS
a. Follow #4 on page 4 “Filling the Water Tank”
b. Follow #5 on page 4 “Filling the Water Tank”
c. Place on level surface
CLICK HERE TO DOWNLOAD AIR INNOVATIONS MH-509 (01) PDF DOCUMENT

I purchased your humidifier model MH-509 from Ace Hardware & the ceramic filter/plug on the bottom was missing. I know I can return it for a refund but I wanted to keep it & figured that I can get a filter/plug by calling them but that didn’t work out ! They wanted me to purchase one & that is not right ! I paid over $80 with tax & they want another($9.98 plus $5.00 S/H) $14.98 for something that should have been with what I paid for originally ? I don’t want to pay twice for this missing part so that puts a bad taste in my mouth 😫 and now reflects on Air Innovations ! After the way they just treated me, a customer, I’LL NEVER EVER PURCHASE A PRODUCT made by AIR INNOVATIONS AGAIN !!! Never, EVER 😠😠😢😥😠 ! ! ! SHAME ON THEM….. SHAME, SHAME, SHAME ! I’m so upset 😡 about this that I feel like tossing that humidifier in the GARBAGE ! If their customer service is this bad 👎 I’m wondering if their products are the same & garbage is what this is ? Thanks, Air Innovations . . . Thanks for nothing !
Leny Williams
960 Deborah Ave.
Elgin, Illinois 60123-1919
Phone #:
630-936-9010
I’m sorry Ace Hardware, in my comments, it sounds like I’m blaming you & I’m not ! I’m blaming the manufacturer of that humidifier which is AIR INNOVATIONS ! That’s who I called & talked to ! Air Innovations. What a joke they are & I don’t want anyone confusing this with you !