Post questions, comments, reviews or page errors in the comment box below.

Click here to download 180 INNOVATIONS KD-113 (01) PDF MANUAL


PDF Content Summary:

****** Page 1 ****** FAST READ DIGITAL CLINICAL THERMOMETER INSTRUCTIONS FOR USE Please read carefully before using FEATURES KD-113 1 2 3 4. 5 6 7 8 9 Fast oral and rectal readings. Memory displays for the last temperature taken Easy to read digital LCD ( liquid crystal display ) Compact, accurate and durable LSI ( large scale integration ) device Temperature can be taken orally or rectally. Very sensitive device, quick to obtain results Ifthe thermometer is inadvertently left on after temperature stabilization , it will automatically shut off in 3 minutes. Small lightweight unit . Universal use for the whole family, especially ideal for children. ABS resin body presents no hazard compared to broken mercury /glass thermometers. 10. Low battery indicator : when the symbol ” O ” or” V “appears , the battery needs to be replaced PARTS DESCRIPTION Sensor SPECIFICATIONS Display Window ONIOFF Button HOW TO USE Special Features NQI-ma.LIe.m.p-e.E.tu.r-e-A-a.r-m: An alarm will sound when the peak temperature has registered and is ready-to-read The “Normal Temperature” alarm (four quick beeps followed by a pause) will sound repeatedly for approximately 8 seconds Last-Temperature Memory Recall: When the ON/OFF button is depressed to activate the thermometer, hold down for approximately 5 seconds. The display of 188.8 will change to show the last measured temperature. This reading is displayed as ong as the button is held down. When the button is released, the thermometer will be in “ready-to-measure” mode and the recalled temperature will be erased Fever Alarm: If the temperature registers higher than 99.50F(37.50 C), the fever alarm (a quick beeping sound which occurs continuously for about 10 seconds) will sound when the peak temperature has registered To change the scale from Fahrenheit (OF) to Centigrade (‘C): After turning the thermometer on, immediately press the ON/OFF button again and release. The OF changes to a ‘C Once the display shows an L with a flashing ‘F or 0 C, the device is ready to record and display a temperature. Follow the same directions to switch back from Centigrade to Fahrenheit. NOTE : Always disinfect the thermometer before you use it. NOTE : In Step 2, if the room temperature is greater than 90 OOF (32.00C), it will be displayed rather than LOF(LOC) NOTE : In Step 3, you may place a sanitary plastic probe shield on the sensor tip to help prevent cross-infection and contamination. Use of the probe cover may result in a 0 20F(0 1 oc) difference from actual temperature. Dispose of used probe shield and store the unit in a safe place RELIABLE METHODS TO MEASURE TEMPERATURE THE TAKING OF BODY TEMPERATURES: Change in body temperature is one of the most important indicators of illness. It is important that accurate temperatures be taken. Even though the digital thermometer is used in similar manner to the glass thermometer, it is important that the simple instructions for use of this thermometer be followed closely and that the person taking the temperature understands body temperature. BODY TEMPERATURE: A person’s body temperature will usually be several tenths to one full degree lower in the morning than it is in the late afternoon. Therefore, if your temperature is 97.90F(36.60C) in the morning, it could be 98 40F(36.90C) or more in the late afternoon and still be normal. To determine what your normal body temperature is you should take your temperature both in the early morning and in the late afternoon over several days. Children have the same normal temperature range as do adults. A fever for both children and adults is typically defined as a temperature over 99 50F(37 50C) (oral reading). Exercise, excessive clothing, hot bath, hot weather, warm food and drink can cause mild elevations of upto 100.40F (380C) to 101.20F(38.40C) in oral temperature. If you suspect one of these to be the cause of an elevated reading, eliminate the possible cause and retake Range Resolution Accuracy Display Battery (included) Power Consumption Battery Life Dimensions Weight Beeper Memory Working Conditions Relative Humidity Storage Conditions Relative Humidity Guarantee of Quality Product Classification PRECAUTION 90.0-109.90F (32.0-43.90C) Below 90.00F (32.00C) displays LOF(OC) Above 109.90F (43.90C) displays HOF(OC) 0.1 OF (OC) (98 OOF 102 OOF) ± 0.30F (96.40F – 97.90F) ± 0.30F (102.1 OF – 106.00F) ± 0.50F less than 96.40F ± O.50F greater than 106.OOF : Liquid crystal display 3 1/2 digits Micro alkaline battery LR41, 192 or ± 010 c ± 0.20C ± 0.20C ± 0.30C ± 0.30 C Battery Cover (37 ooc – 39 OOC) (35.80C – 36.90C) (39.1 oc -41 less than 35.80C greater than 41.00C the temperature in a half hour. ORAL USE Place the probe well under the patient’s tongue. Instruct the patient to keep their mouth closed while the thermometer is reading. A normal temperature by this method is usually considered between 96 80 F to 98.60F(36.OOC to 37.50C) RECTAL USE HEAT POCKET 37.t•c 38.g•c 97.9’F Place probe tip HEAT POCKET 33.vc 36 .g•c 36.6•c Sliver Oxide battery 392, 384, SR41(1 55V) 0.15 milliwatts in measurement mode More than 200 hours of continuous operation • 133mm x 26.5mmx 13mm Approx. 18 grams including battery • Approx. 8 seconds sound signal when peak temperature reached Built-in memory enabling display of previously measured value : Temperature: 50 1040F (10 15 95% non condensing Temperature: -13 1310F (-25- 550C) 15 95% non condensing • Cert. ISO 13485; Complies w/ ASTM-EII 12, EN12470-3, EN60601-1 : Type BF • equipment Instead , clean the unit by wiping it with a dry cloth and disinfect the 1 2 3 4 5 6 8 9 Do not boil the probe probe with isopropyl (rubbing) alcohol Do not drop the thermometer or expose to heavy shock . The unit is not shock proof Do not bend or bite the probe Do not store the unit in direct sunlight, or at a high temperature, or in high humidity or dust. Performance may be degraded Stop using the thermometer if it operates erratically or if display malfunctions Keep out of the reach of unsupervised children 7. Clean the thermometer probe before storing Do not attempt to disassemble the unit except to replace the battery If the thermometer has been stored at below freezing temperatures, allow the thermometer to warm naturally to room temperature before using 10. Performance of the device may be degraded if operated or stored outside stated temperatures and humidity ranges or the patient’s temperature is below the ambient (room) temperature. BATTERY REPLACEMENT 1 2 3 4 5 6 When the symbol” O ” or ” V “appears , the battery needs to be replaced Pull the battery cover off in the direction as shown. If necessary, use a pointed object such as a toothpick or insulated probe to pry loose the battery cover and the old battery Avoid using any sharp metal object in this operation Clean the battery contacts and also those of the device prior to battery re-installation Place a new I .55 VDC button size battery type Micro alkaline battery LR41, 192 or Sliver Oxide battery 392, 384, SR41 or equivalent in the chamber with the positive(+) side up and the negative ( ) side down. Replace and fasten the battery cover securely (back view of thermometer) Warning : Discard old battery carefully, out of reach of young children. Swallowing the battery may be fatal. If the battery is swallowed, contact hospital immediately to have it removed. Do not dispose of the battery in a fire. It may explode. HOW TO USE 1 . Depress the ON/OFF button, The display will read or 2 Release the ON/OFF button and the display will show LOF(LOC) with OF(OC) flashing 3. Disinfect the probe with isopropyl (rubbing) alcohol Place the probe in an appropriate position (oral, axillary, rectal) 4. Once the degree sign CF or oc ) on the display has stopped flashing, the correct temperature is indicated. The temperature reading will not change after the OF(OC) stops flashing For beeper models only, an alarm signal will sound for approximately 8 seconds when OF(OC) stop flashing 5. The unit will automatically turn off in 3 minutes ( approx. ) However, to prolong battery life, it is best to turn the thermometer off by pressing the ON/OFF button once the temperature has been noted If rectal temperature is recommended by your doctor, you may use a probe cover. Insert thermometer into the probe cover. Lubricate the probe cover with a water soluble jelly for easier insertion . Do not use petroleum jelly . Insert tip of probe no more than 1/2 inch into rectum . STOP if you meet any resistance . The sensing device is on the very tip of the probe and there is no need to insert the probe deep into the rectum . In general, the recta temperature is around 1.0 to 2.00F(0.50C to 1.00 C) than oral temperature. AXILLARY USE Wipe armpit with a dry towel . Place probe in the patient’s armpit and keep the patient’s arm pressed firmly against their side. In general, the axillary temperature is around 1 Oto 2.00F (0 5 to 1 OOC) lower than oral temperature. Note that in order to achieve better axillary temperature measurement result, a minimum measurin time of minutes is recommended re ardless of the bee sound. NOTE : Children should be attended by an adult during the entire temperature recording process . After use t, the digital thermometer should be stored in a safe place, out of reach of young children. If you compare temperatures between two thermometers it is possible to have two different readings even if both thermometers are within their accuracy to erances. Differences in how you take each reading and the thermometer’s tolerance range can account for nearly 0.20 F(O. | 0 C) variability. REMEMBER : Find your normal temperature and watch for changes . CLEANING INSTRUCTIONS To clean the thermometer, wash the tip with a solution of mild detergent and cool water Disinfect the thermometer by wiping the sensor and lower stem with a cloth dipped in a household antiseptic solution such as rubbing alcohol LIMITED WARRANTY This thermometer is guaranteed for one year from the date of purchase against manufacturer’s defect under normal, household use. Following the directions closely will ensure years of dependable operation If the thermometer does not function properly, first check the batteries (see battery replacement instructions). Replace them if necessary If the thermometer does not function properly, please write 180 INNOVATIONS at 11100 West 8th Ave, Lakewood, CO 80215 or call customer service at I -877-299-6700. Our representative will provide further instruction on how to correct the trouble or will ask you to return it for repair or replacement FCC STATEMENT NOTE: POTENTIAL FOR RADIO/TELEVSION INTERFERENCE (for U.S.A. only) Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) this device must accept any interference received, inc uding interference that may cause undesired operation This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmfu interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Ifthe product does cause harmful interference to radio or television reception, which can be determined by turning the product on and off, the user is encouraged to try to correct the interference by one or more of the following measures: * Reorient or relocate the receiving antenna ‘k Increase the separation between the product and the receiver * Consult the dealer or an experienced radio/ TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment Thank you for purchacing a 180 INNOVATIONS prouduct Distributed by: 180 INNOVATIONS LAKEWOOD,CO 80215 Manufactured by: Gump Health co.,Ltd Made in China www 180innovations.com Manufactured under U S. Patent No-:US 6,379,039 REV- 20160510 PIN:8211300123


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL

180 INNOVATIONS KD-113 (01) PDF MANUAL

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.