Post questions, comments, reviews or page errors in the comment box below.

Click here to download 180 INNOVATIONS KD-2210 (01) PDF MANUAL


PDF Content Summary:

****** Page 1 ****** 18001NNOVQTIONS INSTRUCTION MANUAL Digital Temple Thermometer Model KD-2210 0197 Manufactured: K-Jump Health Co.t Ltd No-56 Wu Kung 5th Rd., Taipei, Taiwan Distributed By: 180 INNOVATIONS 11100 West 8th Ave, Lakewood, CO 80215 877-299-6700 wwvv. 180innovations.com Memory Mode Recalling Memories: 1. Turn off the unit first 2. Press the POWER button and hold for 3 seconds until the last record is shown. 3. Press the POWER button to choose previous reading no.8M 4. After the POWER button is released, you will hear 2 beeps indicating ready to test. :8881 Ready to test Contents Precaution for Use.. Parts Identification. Preparation for Use…. ….. ….. … How to Operate the Thermometer.. Memory Mode…. Cleaning and Care. Troubleshooting Specifications Limited Warranty.. FCC Statement… IMPORTANT! Read instruction manual before using the thermometer. Quick Start 1 2 4 ..2 .4 .8 10 .11 .12 13 14 Precaution for use 1 Use the thermometer to measure your temple temperature only, the area between the outer corner of the eye and the hairline, right over the temporal artery 2 Do not place the thermometer on scarred tissue, open sores or abrasions. 3 Using drug therapies may raise forehead temperature, which may lead to incorrect measurements. 4 Do not dismantle the unit unless replacing the batteries. Children should not use the 5. thermometer without the supervision of an adult 6. Do not drop or expose thermometer to electric shock as this may adversely affect its performance. 7 The thermometer is not water proof Do not immerse it in water or liquid of any kind 8 To ensure correct readings, please wait for at least 2 minutes between continuous measurements for the thermometer to return to room temperature. 9. Do not use the thermometer when flammable materials are around. 10. Stop using the thermometer if malfunctions appear or if it operates abnormally 11. Clean the thermometer probe after each measurement. Cleaning and Care Please do not drop the unit or expose to heavy shock. The unit is not shock proof. Wipe the tip and probe with an alcohol swab or cotton swab moistened with 70% isopropyl alcohol before & after each use. After cleaning, wait at least 2 minutes before taking a measurement for the unit to readjust to room temperature Use only a soft dry cloth to clean the body of the thermometer (if necessary). Please avoid thinner and benzene or other harsh cleaners Never use an abrasive cleanser or submerge the thermometer in water or other liquids Please remove the batteries if the unit will not be used for a long period Do not expose the thermometer to extreme temperatures, humidity, direct sunlight or shock Store it at room temperature 12. Do not take a measurement if the temple area has just been exposed to direct sunlight, fireplace heat or air conditioner flow, as this may lead to incorrect readings. 13. If thermometer has been kept or stored in a cold temperature, please wait for at least 1 hour for it to return to room temperature before measuring. 14. Operating or storing the unit outside the stated temperature and humidity ranges, or measuring a patient whose temperature is below the room temperature may degrade the performance of the thermometer. 15. Body temperature, like blood pressure, varies from person to person. During the day, it can range from 95.90F to IOO.OOF (35.50C to 37.80C). For some people there can be a difference between their temple and body temperature. We recommend learning your normal temple temperature while healthy so you can detect an elevated one. For accuracy, be sure and measure the same area of the temple each time. Avoid taking a measurement for at least 16. 30 minutes after physical exercise, bathing or eating. 17. Make sure the temporal area is dry and clean of sweat, make-upt etc. 18. Calibration is recommended every two years, Troubleshooting POWER Button LCD Display probe Battery Cover 3. Install 2 new *’AAA” batteries into the battery compartment matching correct polarities. 4. Replace the battery cover securely. t Warning: I Press the POWER button to turn on the unit. A beep sound follows :888! (1) Power on 2. The last memory is displayed. 518;} (2) Last memory 3 You will hear 2 beeps with the measuring scale shown as Figure 4. 4. 5 6. Once the measurement is done, you will hear 2 beeps indicating the reading has been recorded and it is ready to take the next reading. However, we do not recommend consecutive measurements. Waiting Ready for next measurement What are normal temperature values? Human body temperature varies from person to person. Also, a person’s body temperature can fluctuate throughout the day. Therfore, it is very important to know your normal body temperature range. Thus we recommend you measure yourself when healthy to establish referenced temperatures which will make you feel more confident of the measured temperature when ill Preparation for Use Installing/Replacing the Battery 1. Pull the battery cover off in the direction shown. 2 Prior to installing new batteries you must clean the metal contact ends of the batteries and the metal springs and contacts for the batteries in the battery compartment Specifications Measurement Time: 6— 10 seconds Measurement Location: Temporal artery area of forehead Measurement Range: 95.00F- 107.6* (35•C- 4200 Operation Environment: 60.80F-104’F (16•c-4crc) Humidity: 15—95% non condensing Storage Environment: 122’F Humidity: 15 —95% non condensing 7 Turn off the unit by pressing the POWER button, or the unit will automatically turn off after 1 minute of inactivity. I 2 3 4 5 Do not put used batteries in trash Recycle or manage used batteries as hazardous waste. Never dispose of batteries in fire Dispose of used batteries in recycling trash only. Do not recharge, put in backwards or disassemble. This may cause explosion, leakage and injury. (3) Loading (4) Ready to test Install batteries into the thermometer Make sure the polarity is correct Press and release the POWER button Unit will beep once, Wait until it beeps again twice and only OF shows in the display 3. Place and hold the thermometer probe firmly to the skin at the temple and wait several seconds for the device to beep once more Read the temperature on the display POWER SOURCE SIZE AAA 1.5V x 2 (included) WARRANTY: ONE YEAR FROM THE DATE OF PURCHASE (excluding batteries) Memory Mode Deleting Memories: 1 In Recalling memories step, press the POWER button again and hold for 3 seconds until “dEL” shows 2. Press the POWER button to delete all memories then the thermometer will power off automatically. 3 If you don’t press the POWER button, the thermometer will return to Recalling memories step Put the thermometer on the temple It will beep one time to present measurement completion If the temperature reading is over 99 50F (37.50C), eight consecutive beeps will be heard to indicate fever alarm. FCC Statement NOTE: POTENTIAL FOE RADIO/TELEVISION INTERFERENCE (for only) Operation is subject to the following two conditions: I) This device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules, These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation, If the product does cause harmful interference to radio or television reception, which can be determined by turning the product on and off. The user is encouraged to try and correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the product and the receiver. • Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by 180 INNOVATIONS may void the user’s authority to operate this device. Switching between Fahrenheit and Centigrade Scale: You can switch between OF and oc scales. Within 3 seconds after turning on the device, again press and hold the POWER button. The display will show “CH” with no Caution: I Replace with 2 new batteries at the same time. 2 Do not use alkaline, standard (carbon-zinc) and rechargeable (nickel-cadmium) batteries at the same time Limited Warranty This device (batteries excluded) is guaranteed for one year from the date of purchase against manufacturer’s defect under normal use and without evidence of tampering. WARRANTY EXCLUSIONS: • Device is not properly operated according to the instructions as described in this manual • Device shows any signs of tampering or attempted modification. • Evidence of improper handling or storing, such as dropping, electric, heat, liquid or cleaner damage. • Natural disasters (i.e. fire, flood, earthquake, lightening). • No receipt or proof of purchase showing date of purchase Following the instructions closely will ensure years of dependable operation, If the device does not function properly, please contact 180 INNOVATIONS or call 1-877-299-6700. Our representative will provide further instruction to correct the trouble or will ask you to return it along with proof of purchase for repair or replacement. Ex lanation of S mbols Manufacturer (reference label on the device and relevant section in the instruction) Batch code (reference the label on the device) Caution (reference relevant section in the instruction) BF type Type BF applied part Authorized Representative in the European community Stand-by Mode oc Mode Message X Instruction The temperature measured was higher than the specified measuring range Please measure again. The ambient (room) temperature was outside the operating range. Keep it at room temperature (approx. 600F-1040F / 160c-400c) for 30 minutes before using, Poor contact or movement caused the unit to stop measuring. It will turn off automaticallß Make sure both skin and probe are clean (see Cleaning and Care page 10), For best accuracy, wait 2 minutes and measure again being careful not to move probe while measuring. The thermometer has malfunctioned. Please contact distributor. Indicates a low battery condition.Replace with 2 new ‘iAAAn batteries as soon as possible. Replace with 2 new “AAA” batteries immediately. Measurement readout: Fahrenheit or Celsius Accuracy: ± 0.2’F (98-102*F) ± (96.4-97,90F) (102.1- 106T) ± less than 96.40F ± 0.1’C (37—39’C) ± (35.8-36.900 ± o.rc 139.1-41-cj ± less than 35.8″C greater than 41″C ± 0.50F greater than 1060F ±0.rc Batteries: 2 AAA 1.5V batteries (included) Battery Life: Min. 1000 full duty cycles over 24 month period Weight: 1.59 oz (45 grl including batteries Dimensions: x 1.26 x 1.06 (inches) 12.7 x 3.2 x 2.7 (centimeters) Memory: Nine sets Auto Shut Off: after 60 seconds Warranty: 1 year — excluding batteries Classification: Internally powered Type BF equipment The device complies with requirement of ASTM 1 112 Standard Specifications for Electronic Thermometer for Intermittent Determination of Patient Temperature, EN 12470-3 Clinical thermometers Part 3 Performance of compact electrical thermometers (non-predictive and predictive) with maximum device REV. 20160525 PIN:8222100043


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL

180 INNOVATIONS KD-2210 (01) PDF MANUAL

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.