FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF DOCUMENT. FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF USER GUIDE. FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF USER MANUAL. FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF OWNER GUIDE. FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF OWNER MANUAL. FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF REFERENCE GUIDE. FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF INSTRUCTION GUIDE. FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF REFERENCE MANUAL. FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF INSTRUCTION MANUAL. FREE ENGLISH VERTIV LIEBERT PSA5-1000MT120 (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD VERTIV LIEBERT PSA5-1000MT120 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What are the available models for the VERTIV LIEBERT PSA5 series?

The available models and their power ratings for the VERTIV LIEBERT PSA5 series are as follows:

MODEL NUMBER NOMINAL POWER RATING
PSA5-500MT120 500 VA/300 W
PSA5-700MT120 700 VA/420 W
PSA5-1000MT120 1,000 VA/600 W
PSA5-1500MT120 1,500 VA/900 W

What are the functions of the front and rear panel controls and features on the VERTIV LIEBERT PSA5-1000MT120?

The controls and features of the VERTIV LIEBERT PSA5-1000MT120 are detailed below:

ITEM DESCRIPTION
1 Power button.
2 Silence-alarm button.
3 Scroll button. To scroll through the LCD-display parameters.
4 LCD display.
5 USB charging ports, 5 V/2.1 A max. combined.
6 Surge-protected only receptacles.
7 Battery-backed and surge-protected receptacles.
8 USB communication port (Type B).
9 RJ11/45 connectors for phone/fax/modem or network surge protection.
10 Coax connectors for cable-TV or cable-modem or DSS-receiver surge protection.
11 Input Circuit Breaker.
12 Input power cord (NEMA 5-15P).

What is included in the box with the VERTIV LIEBERT PSA5-1000MT120?

The package for the VERTIV LIEBERT PSA5-1000MT120 includes the following items:

• USB cable; one 2 m (6.5 ft) long

• Coax cable; one 1 m (3 ft) long

• Quick Installation Guide

• Safety and Regulatory Guidelines


What should I do after unpacking my VERTIV LIEBERT PSA5-1000MT120?

After unpacking your VERTIV LIEBERT PSA5-1000MT120, you should conduct the following checks:

• Inspect the UPS for shipping damage. If any shipping damage is found, report it to the carrier and your local dealer or your Vertiv representative immediately.

• Check the accessories included in the packaging list. If there is any discrepancy, contact your local dealer or your Vertiv representative immediately.


What are the environmental requirements for installing the VERTIV LIEBERT PSA5-1000MT120?

To ensure proper operation and longevity of your VERTIV LIEBERT PSA5-1000MT120, follow these environmental guidelines for installation:

• Install the UPS indoors in a controlled environment, where it cannot be accidentally turned Off.

• Place it in an area of unrestricted air-flow around the unit, away from water, flammable liquids, gases, corrosives, and conductive contaminants. Avoid direct sunlight.

• The socket outlet should be nearby and easily accessible.

• This UPS is not for use in a computer room as defined in the standard for the Protection of Electronic Computer/Data Processing Equipment ANSI/NFPA 75.

NOTE: Operating the UPS in temperatures above 77°F (25°C) reduces battery life.


What are the installation clearance requirements for the VERTIV LIEBERT PSA5-1000MT120?

Maintain at least 4 in (100 mm) clearance in the front and rear of the VERTIV LIEBERT PSA5-1000MT120. Do not obstruct the air inlets on the front panel and rear panel. Blocking the air inlets reduces ventilation and heat dissipation, shortening the service life of the UPS.


How should I connect loads to the VERTIV LIEBERT PSA5-1000MT120?

The VERTIV LIEBERT PSA5-1000MT120 has 5 battery-backed and surge-protected receptacles and 5 surge-protected-only receptacles. Plug your critical equipment (such as computer, monitors, etc.) into the battery-backed receptacles and your less-critical equipment (such as printers and other less-often used peripherals) into the surge-only receptacles.


How do I use the surge protection features for network, telephone, or TV on the VERTIV LIEBERT PSA5-1000MT120?

To protect your equipment from electrical surges, use the appropriate ports on the rear panel of the VERTIV LIEBERT PSA5-1000MT120:

• For network or telephone protection: Use the network/telephone surge-protection ports. Connect the “IN” port to the line from the wall jack and the “OUT” port to your device port.

• For cable modem, DSS Receiver, or cable-TV protection: Use the coax surge-protection ports. Connect the “IN” port to the line from the wall jack and the “OUT” port to your device port.

Use of these features is not required for proper operation of the UPS.


How do I connect the VERTIV LIEBERT PSA5-1000MT120 to a computer for controlled shutdown?

You can connect the VERTIV LIEBERT PSA5-1000MT120 to a computer via USB to allow for unattended, controlled-shutdown in case of a power failure. The UPS works with the built-in power management software in the Microsoft® Windows® operating system. To use this feature, plug the provided USB cable into the USB Type-B port on the rear panel of the UPS and the other end into an open USB port on your computer.


How do I connect the VERTIV LIEBERT PSA5-1000MT120 to AC power and charge the battery?

First, ensure that all connected loads are powered off. Then, connect the UPS to an input-power supply/wall outlet that is properly protected by a circuit breaker and is grounded. Once the UPS is plugged into the wall outlet, it begins charging the battery.

NOTE: While every precaution has been taken to ensure that the battery is in good condition, it is recommended to allow the UPS to be plugged into AC input and to charge the battery for at least 12 hours prior to providing full back-up time protection for any utility-power abnormality.


What are the different modes of operation for the VERTIV LIEBERT PSA5-1000MT120?

The VERTIV LIEBERT PSA5-1000MT120 has several modes of operation. In all modes, including Off mode, the UPS always provides surge protection and input-breaker protection to all 10 outlets.

Off Mode: The UPS input is plugged in, but the battery-backed outlets are turned off. The internal batteries are charging. The surge-only outlets will still have power.

On/Normal Mode: The UPS input is plugged into a stable source, and the battery-backed outlets are on. The internal batteries are charging.

On/Automatic Voltage Regulation (AVR) Mode: When the input voltage is abnormally low (brown-out), the UPS automatically corrects it to provide normal voltage to the battery-backed outlets. The internal batteries are charging. The surge-only outlets will have the abnormally-low input voltage.

On/Battery Mode: If the input power is lost or unstable, the UPS automatically switches to its internal battery to provide power to the battery-backed outlets. The surge-only outlets will not have power.

Fault Mode: An error has occurred, and the battery-backed outlets are shut off. The surge-only outlets may still have power if the UPS input is plugged in.

Battery Self-test Mode: The UPS runs a 10-second test of the internal battery. This occurs at start-up, automatically every 8 weeks, or when manually initiated.


How do I use the control buttons on the front panel of the VERTIV LIEBERT PSA5-1000MT120?

The functions of the front panel buttons are as follows:

ITEM BUTTON DESCRIPTION
1 Power button • Press-and-hold for 1 second to cycle between On and Off mode.
• Press-and-hold for 3 seconds to enter Battery Self-test mode.
• Press quickly to wake the display.
2 Silence Battery-mode Alarm button • Press-and-hold for 2 seconds during On/Battery mode to mute the battery-alarm beep.
• Press quickly to wake the display.
3 Scroll button • When the UPS is On, press to cycle through UPS operating parameters.
• Press quickly to wake the display.

What do the icons and indicators on the LCD display of the VERTIV LIEBERT PSA5-1000MT120 mean?

The LCD display uses icons and a numeric display to show the status of the VERTIV LIEBERT PSA5-1000MT120. The display automatically powers-off to conserve power but remains on when there is a warning or fault.

ITEM DESCRIPTION
1 Battery mode when lit.
2 Replace battery warning when lit.
3 AC-mode: On solid = Normal mode. Flashing = Automatic Voltage Regulation mode.
4 Output-overload warning when flashing.
5 Site-wiring fault warning when lit.
6 Output-load level graph in 25% increments.
7 Numeric display of UPS operational parameters:
• VAC = input/output voltage
• Hz = input/output frequency
• KW = output power
• MIN = estimated battery back-up time
8 Fault when lit. Fault codes indicated: E01, E02, E03, E04, E05, E06.
9 Battery-capacity graph in 25% increments.
10 Battery-mode alarm muted when lit.

What do the different audible tones and beeps from the VERTIV LIEBERT PSA5-1000MT120 indicate?

The VERTIV LIEBERT PSA5-1000MT120 uses different audible tones to indicate its status:

TYPE INDICATES
1 beep every 10 seconds Battery mode
2 beeps every second UPS warning
2 beeps every 5 seconds Low-battery warning
3 beeps every 30 seconds Replace-battery warning
Constant, solid tone UPS fault
3-second tone followed by 2 beeps Power-on in battery self-test mode
1 long tone Power off
3 beeps Manual battery self-test

How do I troubleshoot warnings on the VERTIV LIEBERT PSA5-1000MT120?

The VERTIV LIEBERT PSA5-1000MT120 has three early-warning indicators. Follow these steps to resolve them:

ICON DISPLAYED AUDIBLE TONE DESCRIPTION SUGGESTED TROUBLESHOOTING
OVERLOAD 1 beep every second Output-overload. The load devices plugged-in to the UPS output are drawing more power than the UPS rating. Reduce the load to below the UPS rating in the specifications table.
SWF Constant, solid tone Site-wiring fault. Problem detected with the outlet wiring to which the AC input of the UPS is connected. Power-off the UPS and contact an electrician to correct the wiring. Possible causes are line and neutral are reversed or there is no ground conductor.
REPLACE 3 beeps every 30 seconds The battery is weak or damaged. Charge the UPS battery for at least 12 hours, or replace the battery.

What do the fault codes on the VERTIV LIEBERT PSA5-1000MT120 mean and how do I resolve them?

If the VERTIV LIEBERT PSA5-1000MT120 detects a problem, it will display a fault code and shut off output power. Refer to the table below for actions:

FAULT CODE DESCRIPTION SUGGESTED TROUBLESHOOTING
E01 Output short circuit. Turn-off the UPS, disconnect all loads, and restart the UPS.
• If the fault is still active, contact Vertiv technical support for a replacement.
• If the fault is no longer active, plug in equipment one at a time to locate the device with the short circuit.
E02 Output overload exceeded warning time, and output is shut off. Turn-off the UPS, disconnect all loads, and restart the UPS. Plug in equipment one at a time and make sure not to exceed the UPS rating for load capacity.
E03 Un-used. Un-used.
E04 Internal inverter circuitry failure during start-up self-test. Turn-off the UPS and call Vertiv technical support for a replacement unit.
E05 Battery-charge failure. Turn-off the UPS and call Vertiv technical support for a replacement unit.
E06 Internal battery is dead or damaged. Charge the UPS for at least 12 hours or replace the battery.

How do I perform a normal start-up of the VERTIV LIEBERT PSA5-1000MT120?

With the VERTIV LIEBERT PSA5-1000MT120 connected to AC input, press-and-hold the power button for 1 second. A long tone and 2 short beeps will sound while the UPS enters battery self-test mode for a few seconds. After a successful self-test, the outlets will turn on.


How do I perform a normal or full shut-down of the VERTIV LIEBERT PSA5-1000MT120?

To fully shut down the VERTIV LIEBERT PSA5-1000MT120, follow these steps:

1. Press-and-hold the power button for 1 second. The outlets are turned off.

2. Disconnect AC-input power.

3. Remove the battery cover and disconnect the battery connector. The unit is now fully shut down.


What are the maintenance precautions for the VERTIV LIEBERT PSA5-1000MT120?

To ensure safety and proper maintenance of your VERTIV LIEBERT PSA5-1000MT120, observe the following precautions:

• Turn off and unplug the UPS before cleaning it.

• Clean the UPS with a dry cloth. Do not use liquid or aerosol cleaners.

• Never block or insert any objects into the ventilation holes or other openings of the UPS.

• Do not place the UPS power cord where it might be damaged.


What are the battery charging recommendations for the VERTIV LIEBERT PSA5-1000MT120?

The batteries in the VERTIV LIEBERT PSA5-1000MT120 are valve-regulated, non-spill-able, lead acid and should be kept charged to attain their design life. The UPS charges the batteries continuously when it is connected to the utility input power. If the UPS will be stored for a long time, it is recommended to connect the UPS to input power for at least 24 hours every 4 to 6 months to ensure full recharge of the batteries.


How do I replace the battery in the VERTIV LIEBERT PSA5-1000MT120?

To replace the internal battery pack in your VERTIV LIEBERT PSA5-1000MT120, follow these steps:

1. Turn the UPS on its side or slide it to the edge of a table.

2. Remove the front battery-compartment cover: While firmly pressing in on the V indentation located in the center just below the USB charging ports, slide the battery compartment cover down, then lift off the cover and expose the battery.

3. Disconnect the battery connector by squeezing and gently pulling the two pieces apart.

4. Slide out the existing battery and disconnect the bottom top half of the connector cable from the two battery terminals. Disconnect the red wire first, then the black.

5. Plug the removed connector into the terminals of the new replacement battery. Plug the black wire in first, then the red.

6. Orient the connector and the replacement battery in the same way as the removed battery and slide into the UPS.

7. Reconnect the two halves of the battery connector and slide the front panel back on until it clicks.

8. Press-and-hold the power button for 3 seconds to initiate the battery self-test and clear any previous battery fault warning.

9. Properly dispose of the old batteries at an appropriate recycling facility or return them to Vertiv in the packing material for the new batteries.


What are the technical specifications for the VERTIV LIEBERT PSA5-1000MT120?

MODEL NUMBER: PSA5-1000MT120
Capacity (VA / W) 1000 / 600
Unit Dimensions, in. (mm) W x D x H 3.9 x 11.4 x 11.0 (99 x 290 x 280)
Unit Weight, lbs (kg) 18 (8.2)
Input AC
Nominal Voltage 120 VAC
Voltage Range 86-143 VAC
Frequency Range 60 Hz, ±5 Hz
Internal Rear-panel Input Breaker Rating 7 A, 250 VAC
Output AC (On Utility)
Nominal Voltage 120 VAC
Voltage Range 105-143 VAC
Output AC (On Battery)
Nominal Voltage 120 VAC
Voltage Range Nominal ±5%
Frequency Range 60 Hz, ±1 Hz
Waveform PWM Simulated Sine wave
Transfer Time 10 ms, max.
Battery
Battery Manufacturer / Model Leoch / DJW12-9.0, CSB / HR1234W or UPS12460
Battery Quantity x VDC x Ah 1 x 12V x 9.0Ah
Environmental Requirements
Operating Temperature, degF (degC) 32-104 (0-40)
Audible Noise <40 dBA @ 3 ft (1 m) from all sides

What are the estimated battery run times for the VERTIV LIEBERT PSA5-1000MT120 at different load percentages?

The approximate battery run times for the VERTIV LIEBERT PSA5-1000MT120 (1000 VA / 600 W) are as follows. These times are based on new, fully charged batteries at 25°C (77°F) with a resistive load.

LOAD PERCENT OF CAPACITY RUN TIME (MINUTES)
10% 53
20% 22
25% 16
30% 14
40% 10
50% 7
60% 5
70% 4
75% 3.6
80% 3.5
90% 2.5
100% 2

CLICK HERE TO DOWNLOAD VERTIV LIEBERT PSA5-1000MT120 (01) PDF DOCUMENT