What are the top system features of the SUPERMICRO SUPERSERVER SYS-322GA-NR?

Feature Description
DIMM Slots 24 DIMMs supporting up to 6 TB 6400 MT/s DDR5 RDIMM or 6 TB 8800 MT/s DDR5 MRDIMM
Drive Bays 6/14 hot-swap E1.S NVMe drive bays or 2/4/6 hot-swap 2.5″ NVMe drive bays
Processor Dual Intel Xeon 6900-series Processors with P-cores up to 500 W
PCIe Slots Up to 10 PCIe 5.0 x16 FHFL or 20 PCIe 5.0 x8 FHFL slots
Power Supplies 3x 3200 W or 2700 W Redundant (2+1) Titanium Level power supplies

What are the front slot configurations on the SUPERMICRO SUPERSERVER SYS-322GA-NR?

Section Slot Description Notes
18, 19 One PCIe GEN5 x16 (FHFL), or two PCIe x8 (FHFL), or two U.2 (2.5″) slots, or six E.1S (15mm) slots Only one configuration per section
20, 21 One PCIe GEN5 x16 (FHFL), or two PCIe x8 (FHFL), or two U.2 (2.5″) slots, or six E.1S (15mm) slots Only one configuration per section
0, 1, 2, 3, 4, 5 One PCIe GEN5 x16 (FHFL), or two PCIe x8 (FHFL) Only one configuration per section

How do I interpret the Information LED status on the SUPERMICRO SUPERSERVER SYS-322GA-NR?

Color, Status Description
Red, solid An overheating condition has occurred
Red, blinking at 1 Hz Fan failure, check for an inoperative fan
Red, blinking at 0.25 Hz Power failure, check for a non-operational power supply
Red, blinking at 10 Hz CPLD recovery mode error
Blue, solid Unit ID has been activated by button
Blue, blinking at 1 Hz Unit ID has been activated using the BMC
Blue, blinking at 2 Hz, and BMC Heartbeat LED on the motherboard is green BMC is resetting
Blue, blinking at 4 Hz BMC is setting factory defaults
Blue, blinking at 10 Hz BIOS/BMC is recovering or updating

What is the function of the UID Button/BMC Button on the SUPERMICRO SUPERSERVER SYS-322GA-NR?

The unit identification (UID) button turns on or off the blue light function of the Information LED. This button can also be used to reset the BMC.


Where can I find the default BMC password for the SUPERMICRO SUPERSERVER SYS-322GA-NR?

Each SUPERMICRO SUPERSERVER SYS-322GA-NR comes with a unique default password for the ADMIN user. This can be found on a sticker on the motherboard and another on the chassis service tag. If necessary, the password can be reset.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD SUPERMICRO SUPERSERVER SYS-322GA-NR (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.