SOLAX POWER GATEWAY-ECC-PLC (01) Image

FREE ENGLISH SOLAX POWER GATEWAY-ECC-PLC (01) PDF USER GUIDE
FREE ENGLISH SOLAX POWER GATEWAY-ECC-PLC (01) PDF USER MANUAL
FREE ENGLISH SOLAX POWER GATEWAY-ECC-PLC (01) PDF OWNER GUIDE
FREE ENGLISH SOLAX POWER GATEWAY-ECC-PLC (01) PDF OWNER MANUAL
FREE ENGLISH SOLAX POWER GATEWAY-ECC-PLC (01) PDF REFERENCE GUIDE
FREE ENGLISH SOLAX POWER GATEWAY-ECC-PLC (01) PDF INSTRUCTION GUIDE
FREE ENGLISH SOLAX POWER GATEWAY-ECC-PLC (01) PDF REFERENCE MANUAL
FREE ENGLISH SOLAX POWER GATEWAY-ECC-PLC (01) PDF INSTRUCTION MANUAL
FREE ENGLISH SOLAX POWER GATEWAY-ECC-PLC (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD SOLAX POWER GATEWAY-ECC-PLC (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What are the general safety notices for using the SOLAX POWER GATEWAY-ECC-PLC?

1. Contents may be periodically updated or revised. SolaX reserves the right to make improvements or changes in the product(s) and the program(s) described in this manual without prior notice.

2. The installation, maintenance and grid-related setting can only be performed by qualified personnel who:

• Are licensed and/or satisfy state and local jurisdiction regulations;

• Have good knowledge of this manual and other related documents.

3. Before installing the device, carefully read, fully understand and strictly follow the detailed instruction of the user manual and other related regulations. SolaX shall not be liable for any consequences caused by the violation of the storage, transportation, installation, and operation regulations specified in this document and the user manual.

4. Use insulated tools when installing the device. Individual protective tools must be worn during installation, electrical connection and maintenance.


What do the labels on the SOLAX POWER GATEWAY-ECC-PLC mean?

SP C US CSA mark of conformity
FC FCC mark of conformity
Caution, risk of electric shock symbol Caution, risk of electric shock
Caution symbol Caution, risk of danger
High voltage 5min symbol Danger of high voltage. Do not touch live parts for 5 minutes after disconnection from the power sources.
Enclosed documentation symbol Read the enclosed documentations
Do not dispose symbol Do not dispose of the inverter together with household waste.

What are the primary cautions for installing the SOLAX POWER GATEWAY-ECC-PLC?

• Before installation, ensure all power of the device has been cut off.

• Do not dismantle or scrap by force.

• Strictly follow the installation guide to connect cables and the enclosure must be well locked before the device is electrified.

• Unauthorized opening and cable connection will void the warranty and cause lethal danger or serious injury due to electric shock.

• Refer to the corresponding installation guide for related safety requirements when it is connected to other devices.

• Anti-static measures should be taken to decrease the damage of static electricity to electronic components.

• Keep away from flammable, explosive materials.

• All the product labels and nameplate on the device shall be maintained clearly visible.


What are the FCC rules for the SOLAX POWER GATEWAY-ECC-PLC?

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.


What items are included in the packing list for the SOLAX POWER GATEWAY-ECC-PLC?

Item No. Items Quantity Description
/ ECC-PLC 1 pc
/ Consumption CT 2 pcs Current: 100 A/33.33 mA
A Documents /
B Crimping terminals 5 pcs
C Plug-in terminal 1 pc Rated voltage/current: 300 V/20 A
D Self-tapping screw 2 pcs
E Expansion tube 2 pcs

* Refer to the actual delivery for the optional accessories.


What are the recommended installation site conditions for the SOLAX POWER GATEWAY-ECC-PLC?

Environmental Conditions:

• Temperature: -40°C to +60°C (-40°F to 140°F)

• Relative Humidity: 5-95%RH

• Ingress Protection: IP20

Installation Location Requirements (Do):

• Install in a location with no direct sunlight.

• Install in a location with no rain exposure.

• Install in a location with no snow lay up.

Installation Location Requirements (Do Not):

• Do not install near combustibles.

• Do not install in direct sunlight.

• Do not install with rain exposure.

• Do not install with snow lay up.

• Do not install near an antenna.


What are the dimensions of the SOLAX POWER GATEWAY-ECC-PLC?

The dimensions of the SOLAX POWER GATEWAY-ECC-PLC are 218 mm x 122 mm x 50 mm.


What are the terminal descriptions for the SOLAX POWER GATEWAY-ECC-PLC?

No. Item Description
A Power For power supply connection
B Production CT port For production CT connection
C Consumption CT port For consumption CT connection
D RS485 port For RS485 connection

What tools and additional materials are needed to install the SOLAX POWER GATEWAY-ECC-PLC?

Installation Tools:

• Hammer drill

• Marker

• Diagonal pliers

• Wire stripper

• Rubber mallet

• Torque screwdriver (Phillips head: ST4.2, Flat head: M2, M3)

• Crimping tool for ferrule

• Measuring tape

• Safety gloves

• Safety boots

• Safety goggles

• Anti-dust mask

Additionally Required Materials:

No. Required Material Requirement Note
1 RS485 communication cable Wire diameter: 28-16 AWG 0.5-1.5 mm² For RS485 connection
2 Water-proof cover We recommended local well-known brand For outdoor installation
3 Guide rail Matching to ECC-PLC For rail mounting of ECC-PLC installation (if you choose wall mounting, this material is not required)
4 Power cable Wire diameter: 15-18 AWG (American-standard) or 1.5 mm² (European standard) For power supply of ECC-PLC
5 Production CT Current: 100 A/33.33 mA Please purchase from SolaX if needed.

What are the overall system installation steps for the SOLAX POWER GATEWAY-ECC-PLC?

1. Install the PV modules and microinverters (refer to the user manual or installation guide of microinverter).

2. Complete the installation map (refer to the user manual or installation guide of microinverter).

3. Install and power on ECC (refer to the user manual or installation guide of ECC) and ECC-PLC.

4. Connect ECC-PLC to ECC.

5. Configurate network on SolaXCloud.

6. On-site inspection of the site on SolaXCloud.


How do I install the SOLAX POWER GATEWAY-ECC-PLC?

Method 1 (Wall Mounting):

1. Use the device to mark the hole positions on the wall.

2. Drill holes with a Ø6 drill to a depth of more than 40 mm.

3. Insert the expansion tubes into the holes.

4. For wooden wall mounting, please skip steps 2 and 3.

5. Screw the self-tapping screws into the expansion tubes. (Torque: 0.5 N·m).

6. Mount the buckles on the back of the ECC-PLC to the self-tapping screws.

Method 2 (Rail Mounting):

1. Mount the buckles on the back of the ECC-PLC to the guide rail.

NOTICE: The rail refers to a rail in the distribution box (with lock) to be wired or a rail in a space that only professional personnel can open.

NOTICE: After installation, please use a cover to cover the device in case of touch by mistake. The device shall be used indoors.


How do I perform the RS485, CT, and power cable connections for the SOLAX POWER GATEWAY-ECC-PLC?

RS485 Connection:

1. Strip 5-6 mm of insulation from the RS485 cable wires, then twist the exposed strands.

2. Insert the wires into the G, A, and B terminals of the plug-in terminal and tighten the screws. (Torque: 0.4±0.1 N·m).

3. After this step, please refer to the ECC User Manual or Installation Guide to connect the ECC-PLC to the RS485-1 port of the ECC.

CT Connection:

Connect the white and black lines of the consumption and production CTs to the corresponding ports as specified in the tables below and tighten the screws (Torque: 0.4±0.1 N·m).

Split-phase CT Connection:

Grid CT number Port
Split-phase Production CT x 2 (optional) White line: 2A+/2B+
Black line: 2A-/2B-
Consumption CT x 2 White line: 1A+/1B+
Black line: 1A-/1B-

Three-phase CT Connection:

Grid CT number Port
Three-phase Production CT x 3 (optional) White line: 2A+/2B+/2C+
Black line: 2A-/2B-/2C-
Consumption CT x 3 White line: 1A+/1B+/1C+
Black line: 1A-/1B-/1C-

Power Cable Connection:

1. Strip 8-10 mm of insulation from the power cable wires.

2. Crimp ferrules onto the wire ends.

3. Insert the wires into the power terminal.

4. Tighten the screws to secure the wires. (Torque: 0.5±0.1 N·m).

Connect the corresponding cables to the ECC-PLC according to the grid type:

Grid PE N L3 L2 L1
Split-phase X
Three-phase

Can you provide the wiring diagrams and connection tables for the SOLAX POWER GATEWAY-ECC-PLC?

Yes, here are the wiring details. We recommend using 1.5 mm² (European standard) or 15-18 AWG (American standard) power cable.

Split-Phase Wiring Diagram Key:

• Red: L1 line

• Black: L2 line

• Yellow: N line

• Green&yellow: PE line

• Blue: CT communication line

• Green: RS485 communication line

• A: Lightning protection equipment

Split-Phase Connection Table:

Connected port/line ECC-PLC port
CT-1 (production CT; optional): White line 2A+
CT-1 (production CT; optional): Black line 2A-
CT-2 (production CT; optional): White line 2B+
CT-2 (production CT; optional): Black line 2B-
L1 line L1
L2 line L2
N line N
PE line PE
CT-3 (consumption CT): White line 1A+
CT-3 (consumption CT): Black line 1A-
CT-4 (consumption CT): White line 1B+
CT-4 (consumption CT): Black line 1B-
ECC: A A
ECC: B B
ECC: GND G

Three-Phase Wiring Diagram Key:

• Red: L1 line

• Black: L2 line

• Grey: L3 line

• Yellow: N line

• Green&yellow: PE line

• Blue: CT communication line

• Green: RS485 communication line

• A: Lightening protection device

Three-Phase Connection Table:

Connected port/line ECC-PLC port
CT-1 (production CT; optional): White line 2A+
CT-1 (production CT; optional): Black line 2A-
CT-2 (production CT; optional): White line 2B+
CT-2 (production CT; optional): Black line 2B-
CT-3 (production CT; optional): White line 2C+
CT-3 (production CT; optional): Black line 2C-
L1 line L1
L2 line L2
L3 line L3
N line N
PE line PE
CT-4 (consumption CT): White line 1A+
CT-4 (consumption CT): Black line 1A-
CT-5 (consumption CT): White line 1B+
CT-5 (consumption CT): Black line 1B-
CT-6 (consumption CT): White line 1C+
CT-6 (consumption CT): Black line 1C-
ECC: A A
ECC: B B
ECC: GND G

NOTICE:

• ECC-PLC is connected under a separate circuit breaker in the distribution box.

• Add a 5 A fuse to the power port of the ECC-PLC.


How do I create a site and configure the WiFi for the SOLAX POWER GATEWAY-ECC-PLC?

Before starting, please make sure that the A1-Micro 1 in 1, ECC, and ECC-PLC have been connected as a system.

Step 1: Download APP.

Scan the QR code in the manual to download the SolaXCloud App.

Step 2: Register an account and log in.

Open the app and follow the prompts to register a new account or log in with existing credentials.

Step 3: Add a site.

In the SolaXCloud app, navigate to add a new site. Enter the required information such as System Size, Country and region, Timezone, and Position. Agree to the terms and click Next.

Step 4: Bind ECC in the added site.

Select the ECC device to add. Ensure the AP hotspot status light on the ECC is on. If not, turn on the AP hotspot according to the diagram in the app. Click “already open ECC hotspot” and then “Next”. Scan the QR code on the device or enter the registration number manually.

Step 5: Configure network for ECC.

Once the device is found, the app will ask to connect to the device’s Wi-Fi. Go to your phone’s Wi-Fi settings and connect to the network named like “WIFI_XXXXXXX”. Return to the app. The app will then ask you to select your home 2.4Ghz Wi-Fi network and enter the password. The app will then proceed through several connection steps: Device hotspot connection, Device communication detection, Connect the device to the router, and Device registration in the cloud. Once successful, click “Finish”.

NOTICE: After ECC configuration succeeds, the connected ECC-PLC will show on the Gateway list. Remember to switch your phone back to your home WiFi for subsequent operation.

Step 7: Bind A1-Micro devices.

Enter the Device Detail interface for the ECC. Click “Manage sub devices” and then “Collecting sub devices” to bind the A1-Micro 1 in 1 devices. The sub-devices will appear in the list.

Step 8 & 9: Check data and graphics.

After binding, click on “Chart” from the Device Details screen to see more detailed information. From the Chart screen, you can see total devices and their status. You can click “Expand” on a specific microinverter to check its live data and performance graphics, such as Power(W), Voltage(V), Current(A), and Temperature(°C).


What do the indicator lights on the SOLAX POWER GATEWAY-ECC-PLC mean?

Indicator Status Description
RUN Green light steady on The connection between ECC-PLC and ECC is normal
Red light steady on The connection between ECC-PLC and ECC is abnormal
Green/red light flashes alternately The ECC-PLC is upgrading (200 ms)

What are the technical specifications of the SOLAX POWER GATEWAY-ECC-PLC?

Power adapter 100~250 Vac 50/60 Hz 1 A input
Voltage acquisition range 100~250Vac
Current acquisition range 0.1~100 A
Carrier power frequency 5~12 MHz
Carrier communication rate 115200 bps
Rated power 20W
Measurement category III
Protection degree IP20
Phase single phase/three phase
Voltage category Split Phase: Rated voltage (L-L): 240 V~
Three Phase: Rated voltage (L-N): 240V~
Altitude 2000 m
MAINS supply voltage fluctuations ±10%
Pollution degree II
Protection degree IP20 (indoor)
Operating temperature range -40°C ~ 60°C ((-40°F to 140°F)
Humidity 5%~95%
Dimensions 218 * 122 * 50 mm
Weight 480 g
Standard CSA C22.2 No. 61010-1-12; UL 61010-1, CSA-C22.2 No. 61010-2-030; UL 61010-2-030; FCC CFR Title 47, Part 15
Compliance UL1741, FCC

CLICK HERE TO DOWNLOAD SOLAX POWER GATEWAY-ECC-PLC (01) PDF MANUAL