Who must install the PHILIPS DYNALITE DTK622-232 Network Gateway?
The PHILIPS DYNALITE DTK622-232 Network Gateway devices must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
What are the electrical specifications for the power input of the PHILIPS DYNALITE DTK622-232?
The power input for the PHILIPS DYNALITE DTK622-232 is 12 V— and 20 mA.
What type of socket is used for the RS-232 connection on the PHILIPS DYNALITE DTK622-232?
The RS-232 connection on the PHILIPS DYNALITE DTK622-232 uses a DB9 Female socket.
What are the pin assignments for the RS-485 DyNet connection on the PHILIPS DYNALITE DTK622-232?
The pin assignments for the RS-485 DyNet (2 x RJ12) connection on the PHILIPS DYNALITE DTK622-232 are as follows:
1 – LOOP
2 – RX
3 – TX
4 – DTR
5 – GND
6 – LOOP
7 – NC
8 – NC
9 – LOOP
What is the operational temperature range for the PHILIPS DYNALITE DTK622-232?
The operational temperature range for the PHILIPS DYNALITE DTK622-232 is 0° C (32° F) to 40° C (104° F).
What is the required humidity range for the PHILIPS DYNALITE DTK622-232?
The required humidity range for the PHILIPS DYNALITE DTK622-232 is $\le$95%.
What is the IEC Overvoltage Category for the PHILIPS DYNALITE DTK622-232?
The IEC Overvoltage Category for the PHILIPS DYNALITE DTK622-232 is Category III.
What is the function of Pin 4 DTR on the DyNet/Auto switch for the PHILIPS DYNALITE DTK622-232 interface?
When set to DyNet, Pin 4 DTR (Data Terminal Ready) controls data flow between RS-232 and RS-485 ports for the PHILIPS DYNALITE DTK622-232.
What does the Auto setting on the DyNet/Auto switch do for the PHILIPS DYNALITE DTK622-232 interface?
When set to Auto on the DyNet/Auto switch for the PHILIPS DYNALITE DTK622-232, it emulates the DTR signal to control data flow when the RS-232 interface implementation does not use the DTR signal.
What is the required installation environment for the PHILIPS DYNALITE DTK622-232 regarding pollution degree?
The PHILIPS DYNALITE DTK622-232 requires installation in an environment meeting IEC Pollution Degree II requirements.
What is a potential consequence if the PHILIPS DYNALITE DTK622-232 is used in a domestic environment?
The PHILIPS DYNALITE DTK622-232 is a class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.