FREE ENGLISH ORBEGOZO ADR 97 (01) PDF DOCUMENT.
FREE ENGLISH ORBEGOZO ADR 97 (01) PDF USER GUIDE.
FREE ENGLISH ORBEGOZO ADR 97 (01) PDF USER MANUAL.
FREE ENGLISH ORBEGOZO ADR 97 (01) PDF OWNER GUIDE.
FREE ENGLISH ORBEGOZO ADR 97 (01) PDF OWNER MANUAL.
FREE ENGLISH ORBEGOZO ADR 97 (01) PDF REFERENCE GUIDE.
FREE ENGLISH ORBEGOZO ADR 97 (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH ORBEGOZO ADR 97 (01) PDF REFERENCE MANUAL.
FREE ENGLISH ORBEGOZO ADR 97 (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH ORBEGOZO ADR 97 (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD ORBEGOZO ADR 97 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What are the general safety instructions for the ORBEGOZO ADR 97?
Please adhere to the following safety instructions when using your ORBEGOZO ADR 97:
1. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children must never play with the appliance. Cleaning and user maintenance must never be carried out by children without supervision.
2. Children should be supervised to ensure that they do not play with the appliance.
3. Keep the appliance and the cable cord out of the reach of children less than 8 years old.
4. WARNING: In order to ensure your children’s safety, please keep all packaging (plastic bags, boxes, polystyrene etc.) out of their reach.
5. If the supply cord is damaged it must be repaired by the Authorized Service Agent in order to avoid hazards.
6. Never pull on the cord when unplugging.
7. Do not use the unit with a damaged cord or plug, or if it is not working properly.
8. Do not handle the appliance with wet hands.
9. Never immerse the appliance in water or any other liquid.
10. Make sure the appliance has been unplugged before cleaning.
11. This appliance must be installed following the national regulations for electrical installations.
12. This appliance is for household use only.
13. WARNING: In case of misuse, there is a risk of possible injury.
What are the additional warnings for the ORBEGOZO ADR 97 with R290 refrigerant gas?
For the ORBEGOZO ADR 97, which uses R290 refrigerant gas, please follow these additional warnings:
• The R290 refrigerant gas complies with European environmental regulations.
• This device contains approximately 175g of R290 refrigerant gas.
• The maximum nominal surface area is 330 m3/h.
• Do not perforate or damage.
• Use only utensils recommended by the manufacturer to defrost or clean.
• Do not use the appliance in a home with any ignition sources that are in continuous operation (for example, gas appliances in operation or an electric heater in operation).
• Do not perforate any components in the refrigerant circuit.
• The refrigerant gas may be odorless.
• An area greater than 9 m2 is required for installation, use and installation of the device.
• Possible leaks of refrigerant gas in homes without ventilation could cause a fire or possible explosion if the refrigerant comes into contact with electrical heaters, estufas or other ignition sources.
• Keep the appliance in place to avoid mechanical failures.
• You can only work in refrigerant circuits for authorized persons who are competent and accredited by an agency that certifies them for refrigerant handling, in conformity with the legislation of the sector.
• All maintenance and repairs that require the assistance of your qualified personnel must be carried out under the supervision of specialists in the use of flammable refrigerants.
What should I do with the ORBEGOZO ADR 97 before its first use?
Please leave the ORBEGOZO ADR 97 sitting outside the box for 24 HOURS before plugging it in.
The product may have been tilted or placed upside down during shipping. Leave the product to sit for 24 hours so the oil in the compressor can settle from the move. Not doing so can affect the performance or life span of the product.
What are the parts of the ORBEGOZO ADR 97?
| 1 | Top control plate | 13 | Window sealing plate connector |
| 2 | Handle | 14 | Air Exhaust Duct Connector |
| 3 | Air outlet louver | 15 | Air Exhaust Duct |
| 4 | Front shell | 16 | Water drainage pipe |
| 5 | Side shell | 17 | Window partition A |
| 6 | Caster | 18 | Window partition B |
| 7 | Upper filter | 19 | Window partition C |
| 8 | Air vent | 20 | Wing nuts (2pcs) |
| 9 | Lower filter | 21 | Gaskets (2pcs) |
| 10 | Continuous drain outlet | 22 | Window screws (2pcs) |
| 11 | Storage socket | 23 | Remote control (without battery) |
| 12 | Drainage hole |
How do I operate the remote controller for the ORBEGOZO ADR 97?
All key functions of the ORBEGOZO ADR 97 can be accessed from the remote control, which acts just like the touch controls on the unit. Do not leave the remote control exposed to direct sunlight.
| MODE | Mode selection |
| SLEEP | Sleep mode |
| TIMER | Timer |
| LOCK | Blocking |
| POWER | On off |
| + | Increase selection |
| – | Reduce selection |
| SPEED | Fan speed |
How do I turn the ORBEGOZO ADR 97 on or off?
Press the POWER key to turn on the machine, and then press it again to turn it off. When you turn it on, the buzzer will beep, and the display and various instructions will light up.
How do I change the operating mode on the ORBEGOZO ADR 97?
The ORBEGOZO ADR 97 has four modes: Cool (cold), Dehu (dehumidifier), Fan (fan) and Heat (heat). Each time the MODE key is pressed, the operating mode and the light indicator for each mode change. The modes change in the following order: Cool → Dehu → Fan → Heat.
How does the TIMER function work on the ORBEGOZO ADR 97?
The TIMER function is used to configure a timed start or shutdown up to 24 hours. The setting method is as follows:
1. With the unit on or off, press the “Timer” key to activate the function. The “Timer” indicator icon will flash.
2. Press the “+” or “-” keys to adjust the set time with an interval of 1 hour.
3. If no operation is performed or any other key except “+” and “-” is pressed within 5 seconds while the “Timer” indicator is flashing, the displayed value will be automatically confirmed.
How do I use SLEEP mode on the ORBEGOZO ADR 97?
Press the SLEEP button to activate or deactivate this mode. When the ORBEGOZO ADR 97 is in sleep mode, the air speed automatically changes to low. In this mode, all lights turn off except the “Sleep” indicator which remains slightly lit. In sleep mode, press the Sleep key to stop it.
How do I use the LOCK mode (child lock) on the ORBEGOZO ADR 97?
In the power on/off state, long press the “LOCK” key for 3 seconds to activate or deactivate the child lock. Once the lock is activated, no key will work except “Lock”, which must be pressed again for 3 seconds to unlock the keyboard.
How do I adjust the fan speed on the ORBEGOZO ADR 97?
Press the SPEED key once to select low or high air speed. The corresponding indicator icons will light up, changing in the order: Low → High.
How do I adjust the temperature or timer settings on the ORBEGOZO ADR 97?
INCREASE “+”:
• In hot and cold mode: Press to increase the temperature by 1°C with each pulse. Hold the button to fast forward. The display will flash to show the set temperature.
• Timer mode: Press this key to adjust the set time upwards, increasing by 1 hour with each press. Hold the button to fast forward. The screen will flash to show the set time.
DECREASE “-“:
• In hot and cold mode: Press to decrease the temperature by 1°C with each pulse. Hold the button to fast forward. The display will flash to show the set temperature.
• Timer mode: Press this key to adjust the set time downward, decreasing by 1 hour with each press. Hold the button to fast forward. The screen will flash to show the set time.
How does the Cold (Cool) mode work on the ORBEGOZO ADR 97?
• Temperature adjustment range: 17 – 30 °C.
• The screen shows the set temperature.
• The Cool mode indicator lights up.
• You can choose the air speed between high and low.
How does the Dehumidifier (Dehu) mode work on the ORBEGOZO ADR 97?
• Temperature/humidity cannot be adjusted.
• The display shows “dH”.
• Air speed cannot be set; it always works in low mode.
• The Dehu mode indicator lights up.
• The equipment automatically establishes the working conditions according to the environmental conditions.
How does the Fan mode work on the ORBEGOZO ADR 97?
• You cannot adjust the temperature.
• The display shows “25”.
• The Fan mode indicator lights up.
• You can choose the air speed between high and low.
How does the Heating (Heat) mode work on the ORBEGOZO ADR 97?
• Temperature adjustment range: 17 – 32 °C.
• The screen shows the set temperature.
• The Heat mode indicator lights up.
• You can choose the air speed between high and low.
How does the memory function on the ORBEGOZO ADR 97 work?
The ORBEGOZO ADR 97 has non-volatile memory.
• If you start the equipment and a power failure occurs, it will turn on after being reconnected and will continue to operate with the previous parameters.
• If the equipment is turned off before a sudden power outage, when the power returns it will remain off.
What does the “Full Tank Reminder” (E7) on the ORBEGOZO ADR 97 mean?
When the internal tank of the ORBEGOZO ADR 97 is full of water, the “Full” icon flashes and the display shows E7. This indicates to the user that the water tank is full. At this time, you must turn off the equipment, drain the water, and restart it so that the equipment can restore normal operation.
How do I install the air outlet tube assembly for the ORBEGOZO ADR 97?
1. Take out the outer connector and air outlet tube and remove the plastic bags.
2. Insert the screw into the hole of window partition A.
3. Insert the window partition B into the window partition A from the side (the wing screw head needs to be stuck into the slot of the window partition B), and adjust the assembly length as required.
4. Turn over the window partition, put the gasket and wing screw in turn and tighten them.
5. Insert the wing screw into the hole of the window partition C.
6. Insert the window partition C into the window partition B from the side (the wing screw head needs to be stuck into the slot of the window partition B), and adjust the assembly length as required.
7. Turn over the window partition, put the gasket and wing screw in turn and tighten them.
8. Stretch both ends to expand the exhaust duct.
9. Turn the air Exhaust Duct Connector to one end of the exhaust duct (clockwise), and then turn the window plate connector to the other end of the exhaust duct (clockwise). The flexible exhaust pipe assembly is now finished.
10. Insert the exhaust pipe assembly (the end of the exhaust joint) into the back-panel vent slot (push to the left) to complete the assembly.
How do I install the window sealing plate and the main body of the ORBEGOZO ADR 97?
Install the Window Sealing Plate Assembly:
1. Half open the window, and mount the window sealing plate assembly to the window. The assembly can be placed in a horizontal or vertical direction.
2. Pull the various components of the window sealing plate assembly open, adjust their opening distance to bring both ends of the assembly into contact with the window frame, and fix the various components of the assembly.
Install the Air Conditioner Body:
1. Place the machine on a flat and dry surface, and keep it away from objects at least 30 cm.
2. Insert the air outlet hose into the window adapter, adjust the window opening width to match the sealing plate correctly, the length is adjustable.
What warnings should I be aware of when installing the ORBEGOZO ADR 97?
• The length of the outlet pipe is adapted to the characteristics of the machine, do not replace or lengthen it freely, otherwise malfunctions will occur.
• Note: The extreme length of the drop down exhaust pipe is 1500mm; Shorten the length as much as possible and keep it as level as possible during installation.
• Adjust the air outlet slats manually and carefully to avoid damaging them.
• Free access to the outlet pipe is important, installation errors will negatively affect the machine.
• Make sure that the air in the outlet tube can circulate smoothly.
When is it necessary to install the exhaust duct on the ORBEGOZO ADR 97?
The installation of the exhaust duct depends on the operating mode of the air conditioner. When the air conditioner is in Auto and Cool mode, it is necessary to install the duct, but when the air conditioner is in Fan or Dehu mode, it is not necessary to install the outlet duct. Users can compress or stretch the exhaust duct according to usage preferences. Do not extend or bend the outlet duct arbitrarily.
How do I install the drain hose on the ORBEGOZO ADR 97?
Install the drain hose in Dehumidifier (Dehu) mode:
In dehumidifier mode, a drain hose must be connected to the continuous drain outlet at the top of the rear of the machine.
• Remove the rubber plug from the continuous drain outlet at the top of the rear of the machine.
• Insert one end of the drain hose into the upper continuous drain outlet.
• Connect the other end of the drain hose to a drain or large capacity container. You must take into account that the drain has to be lower than the drain inlet.
Install the drain hose into the lower tank:
To prevent the lower tank from filling in very humid environments, a drain hose must be connected to the continuous drain outlet on the underside of the rear of the machine.
• Remove the rubber plug from the continuous drain outlet at the bottom of the rear of the machine.
• Insert one end of the drain hose into the lower continuous drain outlet.
• Connect the other end of the drain hose to a drain or large capacity container. You must take into account that the drain has to be lower than the drain inlet.
How do I clean and maintain the ORBEGOZO ADR 97?
Caution: To avoid electric shock, you must turn off the appliance and unplug it before performing cleaning and maintenance tasks.
1) Machine cleaning:
Clean the machine with a soft, slightly damp cloth.
2) Cleaning the filter screen:
• Take out the two filters (1 and 2).
• Clean the filter: Use a vacuum cleaner to gently vacuum the dust from the filter surface. If the filter grate is very dirty, clean it with warm water and a mild detergent and dry it completely.
• Replace filters 1 and 2.
3) Storage:
To store the machine if it will be unused for a long time, pay attention to the following steps:
1. Remove the drain plug from the bottom pan and drain the water completely. Clean the machine body and filter grill.
2. Select “Fan” mode to dry the inside of the air conditioner completely.
3. Turn off the power switch, coil and tie the power cord.
4. Place the machine in a cool and dry environment.
What are the key safety precautions to observe while using the ORBEGOZO ADR 97?
• Do not place the machine on soft and uneven ground to avoid vibration or movement.
• Do not insert rods or hard objects into the machine to avoid failure or danger.
• Keep the machine away from heat sources such as heaters and electric kettles when using it.
• Close doors and windows to achieve the best cooling effect.
• Do not place objects in front of and behind the machine. If the ventilation is blocked, the cooling effect will be affected.
• Unplug the air conditioner when not in use for a long period of time.
• Wipe the machine body gently with a damp cloth and do not shoot water directly.
• Please do not put anything on the machine.
• Clean the filter screen once every two weeks (never use hot water over 40°C, alcohol or gasoline).
• In continuous drainage, the drain pipe must be placed in a horizontal position, without coiling.
• Do not dry the filter in direct sunlight to avoid deformation.
• Before moving the machine, drain any water accumulated in the lower tank.
How can I troubleshoot problems with my ORBEGOZO ADR 97?
| Problem | Cause |
|---|---|
| The unit does not turn on |
• The plug inserted properly. • Low battery in the remote control. • Please wait three minutes in case the system is protected. |
| Too much time without working | You can lower the selected temperature, the previous one may be very close to the ambient temperature. |
| Air comes out, but the cooling/heating effect is not good |
• The air exit is obstructed. Please eliminate the obstacle. • The door or windows are open. Air outputs cause a poor room insulation effect. • The filter is blocked. Please limit it. • The air outlet or entrance is blocked. • The established temperature is too high or too low. • Erroneous mode, incorrect temperature and air speed configuration. |
| Water leak when moving |
• Drain the water from the tank before moving the device. • Verify that the continuous drain plugs is well placed and in good condition. |
| The display does not turn on when the device | Bad contact between the plug and the power outlet or disconnection of the power cable, without energy supply. |
| There is no response when pressing the function keys | Check if the children’s lock function is configured. |
| Abnormal sound | A few minutes before starting the machine, it is normal to feel a slight vibration and an abnormal sound. |
| There are water drops on the surface. |
• It is normal for air exit, panel and other parts to produce water drops when they work under conditions of high environmental humidity. • If it works in open spaces for a long time in cold mode, water drops will be generated. Please close the doors and windows. • An too low air speed can cause water droplets, increase speed. • This phenomenon may also be due to an opening angle that is too small from the frontal lams. Open the lamps or configure it to automatically oscillate. |