What are the key safety warnings for the OMRON ZS-HLDS5?
Never look into the laser beam. Doing so continuously will result in visual impairment.
Do not disassemble the product. Doing so may cause the laser beam to leak, resulting in the danger of visual impairment.
What are the general safety precautions for using the OMRON ZS-HLDS5?
1. Do not use the product in environments where it can be exposed to inflammable/explosive gas.
2. Do not disassemble, repair or modify this product.
3. Be sure to make sure that locking mechanisms are locked before use.
4. Dispose of this product as industrial waste.
In which environments should the OMRON ZS-HLDS5 not be installed?
Do not install the product in locations subjected to the following conditions:
• Reflection of intense light (such as other laser beams or electric arc-welding machines)
• Presence of dust, oil droplets or spray on the filter on the front of the Sensor Head
• Presence of corrosive or flammable gases
• Direct vibration or shock
What pre-installation checks should be performed for the OMRON ZS-HLDS5?
The product cannot accurately measure the following types of objects:
• transparent objects, objects having an extremely low reflection factor, objects smaller than the spot diameter, objects with a large curvature, excessively inclined objects, etc.
What are the wiring precautions for the OMRON ZS-HLDS5?
• Avoid wiring the cable between the Sensor Head and Sensor Controller including this product near high voltage lines and power lines. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage.
• Before connecting/disconnecting the Sensor Head, make sure that the Smart Sensor is turned OFF. The Smart Sensor may break down if the Sensor Head is connected or disconnected while the power is ON.
How should the OMRON ZS-HLDS5 be cleaned?
Do not use paint thinner, benzene, acetone or kerosene to clean the Sensor Head as doing so will melt the surface of the Sensor Head.
• To remove dust particles, use a blower brush.
• To remove stubborn dirt, wipe gently with a soft cloth moistened with a small amount of alcohol.
What are the compatibility and cable extension details for the OMRON ZS-HLDS5?
Compatibility
The Sensor Head is compatible with the Sensor Controller, and can be used if purchased separately.
Cable extend
This product can’t be connected to long extension cables for sensor head (Model ZS-XCCR, Model ZS-XC02D and Model ZS-XEQ).
What are the laser safety handling precautions for the OMRON ZS-HLDS5?
The OMRON ZS-HLDS5 emits a visible laser beam. Do not stare directly into the laser. Make sure that the laser beam path is terminated.
A non-reflective matte painted surface is ideal at the end of the laser beam path.
If specular objects are present in the laser beam path, make sure that they are prevented from reflecting the laser beam. When used without an enclosure, make sure the laser path from eye level is avoided.
What are the laser safety and labeling requirements when using the OMRON ZS-HLDS5 in the USA?
When the OMRON ZS-HLDS5 is exported to the USA, it falls under the laser regulations of the FDA (Food and Drug Administration). The ZS-HLDS5 is classified as a class-II laser by 21CFR1040. It is assumed that the product will be incorporated into a final system device. When incorporating the OMRON ZS-HLDS5, comply with the following technical standards: US Federal Law 21 CFR 1040.10 and 1040.11.
What are the laser safety and labeling requirements when using the OMRON ZS-HLDS5 in China?
The OMRON ZS-HLDS5 is classified into Class 2 by the GB/T 7247.1-2024 standard. When using in China, warning labels must be replaced by Chinese ones supplied with the product.
What are the laser safety and labeling requirements for using the OMRON ZS-HLDS5 in countries other than Japan, the U.S., and China?
When used in countries other than Japan, the U.S. and China, warning labels must be replaced by suitable ones for the area, supplied with the product. The OMRON ZS-HLDS5 is classified into Class 2 by the IEC 60825-1:2014/EN 60825-1:2014+A11:2021 standard.
How should the ferrite core be attached to the OMRON ZS-HLDS5?
Attach three ferrite cores (provided with the Sensor Head) to the Sensor Head side of the Sensor Head cable, and attach one ferrite core to the connector side of the Sensor Head cable.
If the ferrite core comes loose from the cable, fasten the ferrite core in place with the Insure Lock (supplied).
What do the NEAR and FAR indicators on the OMRON ZS-HLDS5 signify?
NEAR indicator
• Lit near measuring center distance, and nearer than measuring center distance inside the measuring range.
• Blinks when the measurement target is outside of the measuring range or when the received light amount is insufficient.
FAR indicator
• Lit near measuring center distance, and further than measuring center distance inside the measuring range.
• Blinks when the measurement target is outside of the measuring range or when the received light amount is insufficient.
What are the specifications of the OMRON ZS-HLDS5?
| Item | Model | ZS-HLDS5 | ZS-HLDS5T | |
|---|---|---|---|---|
| Optical system | Diffuse reflection | Regular reflection | Diffuse reflection | Regular reflection |
| 50mm | 44mm | 50mm | 44mm | |
| Measuring center distance | ±5mm | ±4mm | ±5mm | ±4mm |
| Measuring range | Visible semiconductor laser (wavelength 650 nm, 1mW max., Class 2) | |||
| Light source | 30×1000 μm | |||
| Beam diameter (*1) | ±0.1%F.S. | |||
| Linearity (*2) | 0.1 μm | 0.25μm | ||
| Resolution (*3) | ±0.01%F.S./°C | |||
| Temperature characteristic (*4) | 110 μs | |||
| Sampling cycle (*5) | Illumination on received light surface 3000 lx or less (incandescent light) | |||
| Operating ambient illumination | Operating: 0 to +50°C, Storage: -15 to +60°C (with no icing or condensation) | |||
| Ambient temperature | Operating and storage: 35% to 85% RH (with no condensation) | |||
| Ambient humidity | Cable length 0.5 m: IP66, cable length 2 m: IP67 | |||
| Degree of protection | 10 to 150 Hz, 0.35-mm half amplitude 80 min each in X, Y, and Z directions | |||
| Vibration resistance (destructive) | 150m/s² 3 times each in six directions (up/down, left/right, toward/backward) | |||
| Shock resistance (destructive) | Case: aluminum die-cast, front cover: glass | |||
| Materials | 0.5 m, 2 m | |||
| Cable length | Approx. 600 g | |||
| Weight | Laser label (1 each for JIS/EN/GB, 3 for FDA), Ferrite core (4 pcs), Insure Lock (2 pcs), Instruction Sheet | |||
*1 Defined as 1/e² (13.5%) of the center optical intensity in the measurement center distance (effective value). The beam diameter is sometimes influenced by the ambient conditions of the workpiece such as leaked light from the main beam.
*2 This is the error on the measured value with respect to an ideal straight line. In the diffuse reflection mode, the standard workpiece is white aluminum ceramic, and is glass in the regular reflection mode. Linearity may change according to the workpiece.
*3 This is the “peak-to-peak” displacement conversion value of the displacement output in the measuring center distance when the number of samples to average is set to 512, and the measuring mode is set to high-resolution mode. In diffuse reflection mode, the standard workpiece is white aluminum ceramics, and glass in the regular reflection mode.
*4 This is the typical value obtained in the measuring center distance when the sensor and workpiece are fixed by an aluminum tool.
*5 This value is obtained when the measuring mode is set to the high speed mode.
For what types of applications is the OMRON ZS-HLDS5 not suitable?
Never use the product for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the Omron product(s) is properly rated and installed for the intended use within the overall equipment or system.