What does the “WARNING” indication signify?

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Additionally, there may be severe property damage.


Can this product be used for detecting human bodies in safety-related applications?

No, this product is not designed for use in directly or indirectly detecting human bodies in safety-related applications. Do not use the product as a sensing device for human protection.


What are the general precautions for safe use of this product?

Observe the following precautions to ensure safe usage of the product:

1. Do not use the product in environments subject to inflammable, explosive, or corrosive gases.

2. Do not disassemble, repair, or modify the product in any way.

3. Tighten the base mounting screws and terminal block screws securely.

4. Use the specified sizes of crimp terminals for wiring.

5. Always lock the lock mechanisms on any devices provided with them, such as cable connector lock screws.

6. Confirm that the DC power supply is within the rated power supply voltage (24 VDC +10%/-15%) before using it.

7. Do not reverse polarity when connecting the power supply.

8. Do not allow water to enter or insert wire in the gaps of the case. Fire or electric shock may result.

9. Always turn OFF the power supply to the ID Controller before attaching or removing the Antenna and Amplifier section.

10. If you suspect that anything is wrong with the product at any time, stop using it immediately, turn OFF the power supply, and consult with your OMRON representative.

11. When disposing of the product, dispose of it as industrial waste.


What should be done if this Class A product causes radio interference in residential areas?

This is a class A product. In residential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference.


Where should this product NOT be installed?

Do not install the product in the following locations:

• Locations subject to corrosive gases, dust, dirt, metal powder, or salt

• Locations where the specified ambient operating temperature range is exceeded

• Locations subject to extreme temperature changes that may result in condensation

• Locations where the specified ambient operating humidity range is exceeded

• Locations where the product would be directly subjected to vibration or shock exceeding specifications

• Locations subject to contact with water, oil, or chemicals


What frequency band does this product use and what precautions should be taken regarding electromagnetic interference?

The product uses the 13.56MHz frequency band to communicate with Tags. Some devices, such as some motors, inverters, and switch mode power supplies, generate electromagnetic waves (i.e., noise) that can affect communications with the Tags. If any of these devices are nearby, communications with Tags may be affected or Data Carriers may be destroyed. If the product is to be used near such devices, check the effects on communications before using the product.


What are the precautions to minimize the general influence of noise during installation?

To minimize the general influence of noise, follow the following precautions:

(1) Ground the earth terminal of this product and any metallic material located around the product to 100Ω or less.

(2) Keep product wiring away from high voltage or heavy current.


Is the product waterproof?

The product does not provide a water-proof structure. Do not use it where mists are present.


What chemicals should be avoided with this product?

Do not use chemicals that will affect product materials.


What is the tightening torque for mounting screws?

Tighten screws to 1.2 N·m when mounting the product.


What should be considered if more than one Read/Write Antenna is installed in the same vicinity?

Communications performance may be reduced due to mutual interference if more than one Read/Write Antenna is installed in the same vicinity. Refer to the Read/Write Antenna and Tag Operation Manual (Cat. No. Z248-E1) and confirm that there is no mutual interference between Read/Write Antennas.


Where should this product NOT be stored?

Do not store the product in the following locations:

• Locations subject to corrosive gases, dust, dirt, metal powder, or salt

• Locations where the specified ambient storage temperature range is exceeded

• Locations subject to extreme temperature changes that may result in condensation

• Locations where the specified ambient storage humidity range is exceeded

• Locations where the product would be directly subjected to vibration or shock exceeding specifications

• Locations subject to contact with water, oil, or chemical


How should this product be cleaned?

Do not use thinners for cleaning. Resin materials and the case coating will be dissolved by thinners, benzenes, acetones and kerosenes.


To comply with UL508, the product must be connected to one of which two types of circuits?

Use the product connected to one of the following two circuits:

(1) Limited Voltage/Current Circuit (Approved in UL508)

(2) A circuit with a maximum voltage of 30 Vrms (42.4 V peak) that uses as its power supply a Class 2 power supply defined in UL1310 or a Class 2 transformer defined in UL1585.


What are the specifications for a UL508 Approved Limited Voltage/Current Circuit that can power this product?

A circuit that uses as its power supply the secondary coil of an insulated transformer that satisfies the following conditions:

• Maximum voltage (with no-load): 30 Vrms (42.4 V peak) OR

• Maximum current: (1) 8 A (including when shorted) OR

(2) A current restricted by a circuit protective device (e.g., fuse) with the following ratings:

No-load voltage (V peak) Maximum current rating (A)
0 to 20 5.0
Over 20 to 30 100 / Peak voltage

What are the specifications for a UL1310 or UL1585 Class 2 power supply circuit that can power this product?

A circuit with a maximum voltage of 30 Vrms (42.4 V peak) that uses as its power supply a Class 2 power supply defined in UL1310 or a Class 2 transformer defined in UL1585.


How should the product be mounted on a control panel?

When mounting directly to a control panel, always use flat washers and M4 screws. Tightening torque: 1.2 N·m.


How is the ID Controller mounted to a DIN Rail?

(1) When mounting the ID Controller to DIN Rail, hook the ID Controller at point A and then press in direction B.


How is the ID Controller removed from a DIN Rail?

(2) To remove the ID Controller from the DIN Rail, pull out the mounting hook.


What is the recommended DIN Rail for this product?

Recommended DIN Rail: PFP-100N2 (rail length: 1 m) (manufactured by OMRON).


What are the Input Specifications (RST, TRG1, and TRG2) for the ID Controller?

Item Specification
Input voltage 24 VDC +10% (including ripple) / -15% (PNP or NPN)
Input impedance 2.2 kΩ
Input current 10 mA typical (24 VDC)
ON voltage 19 V min.
OFF voltage 5 V max.
I/O response time 70 ms max.

What are the Output Specifications (RUN, BUSY/OUT3, ERROR/OUT4, OUT1 and OUT2) for the ID Controller?

Item Specification
Maximum switching capacity 24 VDC +10% (including ripple) / -15%, 100mA photo MOS outputs (PNP or NPN)
Leakage current 100 µA max.
Residual voltage 2.0 V max.

Note 1: The CPU will stop operation and the RST indicator will light when the RST input is turned ON. The ERROR output will be reset at that time.

Note 2: The transistor may be damaged if an output is shorted with no load connected.


What happens when the RST input is turned ON?

The CPU will stop operation and the RST indicator will light when the RST input is turned ON. The ERROR output will be reset at that time.


What can happen if an output is shorted with no load connected?

The transistor may be damaged if an output is shorted with no load connected.


What are the General Specifications for the ID Controller?

Item Specification
Power supply voltage (power consumption, current consumption) 24 VDC (-15% to +10%) (15 W max., 0.8 A max.)
Ambient operating temperature -10 to +55 °C (with no icing)
Ambient operating humidity 25% to 85% (with no condensation)
Ambient storage temperature -25 to +65 °C (with no icing)
Ambient storage humidity 25% to 85% (with no condensation)
Insulation resistance Between power supply terminals and GR/Case
Between GR and terminals
Dielectric strength Between power supply terminals and GR/Case
Between GR and terminals
Vibration resistance 10 to 150 Hz with 0.2mm double amplitude and 15m/s² maximum acceleration, 10 sweeps of 8 minutes each in three directions
Shock resistance 150 m/s²
Dimensions 105 x 90 x 65 mm (excluding protrusions)
Degree of protection In-panel (equivalent to IP20)
Materials PC + ABS
Weight Approx. 300 g
Installation method DIN Rail or M4 screws
Antenna Connections V680-CA5D01-V2:1channel, V680-CA5D02-V2:2 channels

Note: The specific values for Insulation resistance and Dielectric strength were split in the original table and visually associated. The extracted table above maintains the items, but the PDF shows “20 MΩ (at 500 VDC mega)” for insulation resistance and “1,000VAC 50/60Hz for 1 minute” for dielectric strength associated with these rows.


How should this product be disposed of?

Dispose in accordance with applicable regulations. When disposing of the product, dispose of it as industrial waste.