OMRON ZX-GIF41 (01) Image

FREE ENGLISH OMRON ZX-GIF41 (01) PDF USER GUIDE
FREE ENGLISH OMRON ZX-GIF41 (01) PDF USER MANUAL
FREE ENGLISH OMRON ZX-GIF41 (01) PDF OWNER GUIDE
FREE ENGLISH OMRON ZX-GIF41 (01) PDF OWNER MANUAL
FREE ENGLISH OMRON ZX-GIF41 (01) PDF REFERENCE GUIDE
FREE ENGLISH OMRON ZX-GIF41 (01) PDF INSTRUCTION GUIDE
FREE ENGLISH OMRON ZX-GIF41 (01) PDF REFERENCE MANUAL
FREE ENGLISH OMRON ZX-GIF41 (01) PDF INSTRUCTION MANUAL
FREE ENGLISH OMRON ZX-GIF41 (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD OMRON ZX-GIF41 (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What environmental precautions should be observed for safe use of the Smart Sensor?

Do not use the Smart Sensor in locations subject to explosive or flammable gases.

To ensure safety in operation and maintenance, do not install the Smart Sensor near high-voltage equipment or power devices.


What power supply and wiring precautions are necessary for safe use?

Do not apply voltage exceeding the rated voltage (24VDC +10%, -15%).

When supplying power to the Sensor, make sure that the polarity of the power is correct, and do not connect to an AC power supply.

Do not short-circuit a load for outputs.

Do not lay a power supply cable for the Smart Sensor together with high-voltage lines or power lines. Doing so, or placing them into the same duct would cause induction and lead to malfunction or damage.

When the Controller is connected and used mutually, Please use this product by combining specification.


What other precautions should be taken for safe use?

Do not attempt to disassemble, repair, modify, deform or burn this product.

When disposing of the Smart Sensor, treat it as industrial waste.

Please contact our branch and the office after it turns off power when you feel abnormality by any chance.


Where can I find detailed information for the functions and operation of the ZX-GT-series Smart Sensors?

Detailed information for the functions and operation of the ZX-GT-series Smart Sensors is available in an Operation Manual (Cat. No.SCHE-746), which is sold separately. Ask your OMRON representative for details.


In what types of environments should the Smart Sensor not be installed for correct use?

Locations subject to strong electromagnetic fields or in an environment where the operation of the Sensor is subject to the reflection of intense light (such as other laser beams or electric arc-welding machines.)

Locations where the ambient temperature exceeds the rated temperature range.

Locations subject to rapid changes in temperature (causing condensation).

Locations where the relative humidity exceeds the range of 35% to 85%.

Locations subject to corrosive or flammable gases.

Locations where dust, salt, or metallic powder accumulate on the Sensor.

Locations subject to direct vibration or impact.

Locations subject to direct sunlight.

Locations subject to exposure to water, oil, chemicals, etc.

Locations subject to strong electromagnetic or electrical fields.


What power supply and wiring precautions should be followed for correct use?

When using a commercially available switching regulator, ground the FG (frame ground) terminal.

If the power supply line is subject to surges, connect a surge absorber that meets the conditions of the usage environment.

Do not connect/disconnect the Controller from the Interface Unit with power on, or it might get damaged.


Is there a warm-up period required for the Smart Sensor?

After turning ON the power, allow the Smart Sensor to warm up for approximately 10 minutes prior to use. The circuitry is not stable immediately after turning the power ON, and the values gradually change until the Sensor is completely warmed up.


What are the maintenance and inspection guidelines for the Smart Sensor?

Always turn OFF the power supply before adjusting or removing the Sensor Head.

Do not use thinners, benzene, acetone, or kerosene for cleaning the Sensor Head or Controller.


How are the accessory clamps used?

The clamps provided with the Unit can be used to secure the serial communication cable.


How do I connect the Communications Interface Unit to the Sensor Controller?

After mounting the Unit and Controller to DIN Track, press the Unit against the left side of the Controller.


How do I remove the Communications Interface Unit from the DIN Track?

Press the Unit toward the front.

Lift the front of the Unit.


What do the indicators on the Communications Interface Unit mean?

Indicator Name Color Description
Power indicator Green Lit when power is supplied to the Unit.
Controller communication indicator Orange Lit when controllers are communicating with each other normally.
Controller communication error indicator Red Lit when there is a communication error between controllers.
RS-232C communication indicator Green Lit when the Unit is communicating normally with the external device. (e.g., computer)
RS-232C communication error indicator Red Lit when there is a communication error with the external device. (e.g., computer)
Binary output indicator Yellow Lit while the binary output is outputting.

Note: The controller communication error indicator will be on for 1 second after the power supply is turned ON, but this does not indicate an error.


What is the condition for using the ZX-GSW11 software?

The software may be used only when the user agrees with the terms specified in the License.txt file in the setup desk.


How do I mount the Communications Interface Unit to a DIN Track?

① Mount the front of the Unit to the DIN Track.

② Press the rear of the Unit onto the DIN Track.

Note: Always mount the front of the Unit first. Mounting strength may decrease if mounting is performed in the reverse order.


What is the correct position for the switch on the bottom of the Unit?

There is a switch on the bottom of the Unit. This switch must be left in the factory-set position shown in the diagram. If the switch is changed position, communication do not work.


What is the RS-232C Connector PIN Assignment for the ZX-GIF SIDE and Personal Computer SIDE?

ZX-GIF SIDE Personal Computer SIDE
Pin Signal Pin Signal
1 N.C. 1 CD
2 RD 2 RD
3 SD 3 SD
4 N.C. 4 ER
5 SG 5 SG
6 N.C. 6 DR
7 N.C. 7 RS
8 N.C. 8 CS
9 N.C. 9 CI
connector food FG

What are the wire color assignments for the output cable connections?

Wire Color Signal
Light Blue GATE
Red/White D11
Black D10
Yellow D9
Brown D8
Blue D7
Pink D6
Gray D5
Green D4
White D3
Orange D2
Red D1
Purple D0
Light Green N.C.

How should a load be connected for the NPN type output?

For the NPN type output, connect the load between the respective output wire (e.g., Purple for D0, Red for D1, etc., up to Red/White for D11) and the positive terminal of the power supply (Brown DC12-24V). The common (GND) is Blue (0V). The GATE output is also NPN.


How should a load be connected for the PNP type output?

For the PNP type output, connect the load between the respective output wire (e.g., Purple for D0, Red for D1, etc., up to Red/White for D11) and the negative terminal of the power supply (Blue GND(0V)). The positive supply is Brown (DC12-24V). The GATE output is also PNP.


What are the ratings and performance specifications for the Model ZX-GIF11(A)/41(A)?

Item Specification for Models ZX-GIF11, ZX-GIF11A, ZX-GIF41, ZX-GIF41A (unless specified otherwise)
Agreement controller ZX-GTC11/ZX-GTC41
Indicator Lamp Power indicator (green)
Controller communication indicator (orange)
Controller communication error indicator (red)
RS-232C communication indicator (orange)
RS-232C communication error indicator (red)
Binary output indicator (yellow)
Communication Port RS-232C (9-pin, D-Sub connector)
12 bit binary output (D0-D11, GATE) For ZX-GIF11, ZX-GIF11A: NPN Open collector output, 30VDC 20mA max., Residual voltage 1.2V or less
For ZX-GIF41, ZX-GIF41A: PNP Open collector output, 30VDC 20mA max., Residual voltage 2V or less
Power supply From controller (60mA max.)
Dielectric strength 1000VAC at 50/60Hz for 1min
Insulation resistance 20MΩ at 500VDC
Ambient temperature Operating: 0 to +50°C, Storage: -15 to +60°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35 to 85% (with no condensation)
Vibration (durability) 10 to 150Hz Half-amplitude of 0.35mm for 80 minutes each in X, Y, and Z directions
Protective structure IEC60529 IP20
Cable length 2m
Material Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Accessories Instruction manual, two clamps
Weight (packed state) ZX-GIF11: Approx. 330g
ZX-GIF11A: Approx. 550g
ZX-GIF41: Approx. 330g
ZX-GIF41A: Approx. 550g


CLICK HERE TO DOWNLOAD OMRON ZX-GIF41 (01) PDF MANUAL


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.