Where can I download the IO-Link setting file (IODD file)?
You can download the IO-Link setting file from the official company website (www.fa.omron.co.jp).
What is the minimum cycle time for COM2 and COM3?
For COM2 (38.4kbps), the minimum cycle time is 3.5ms.
For COM3 (230.4kbps), the minimum cycle time is 1.2ms.
What does the diagnostic output indicate when the sensor cannot continue operation due to a recoverable factor such as a load short-circuit or a service data error?
0: Normal.
1: Error.
What does the diagnostic output indicate when the sensor has an internal error and replacement is needed?
0: Normal.
1: Error.
What is the meaning of each value in the “Device Status” service data?
0x00: Operating properly.
0x01: Insufficient incident light level error.
0x02: Distance error.
0x04: Breakdown.
What should I do if the sensor is broken internally?
Restart the sensor. If the error occurs again, replace the sensor.
What should I do if inconsistency has occurred on the settings (service data) written in by the IO-Link communications?
Reset the system command settings to initialize the setting values. Refer to Index 2 of the service data.
What should I do if over current is flowing to Control Output 2?
Check the wiring to the sensor and make sure that the load current is within ratings.
What are the options for the “Output1 Switchpoint Logic”?
The options are:
0x00: NO (Normally Open)
0x01: NC (Normally Close)
What are the options for the “Output1 Switchpoint Mode”?
The options are:
0x01: Single Point
0x80: Output1 Invert
What are the options for the “Output1 Timer (Mode)”?
The options are:
0x00: Disable
0x01: ON Delay Timer ON Delay
0x03: One Shot Timer One Shot
What are the options for “Key Lock”?
The options are:
0x00: Umlock
0x01: Valid (Button Release is Possible) Lock
0x02: Valid (Button Release is Impossible) Lock (No Button)
What does the “Keep Function” do?
It sets the specification of output when measurement error (Distance error, Insufficient incident light level error).
What happens when you set “Keep Function” to 0x00?
Control output OFF.
What happens when you set “Keep Function” to 0x01?
Maintain the output status just before the measurement error.
Table: Process data
| bit | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|---|
| Assignment | Details | |||||||
| 0: OFF 1:ON |
0: OFF 1:ON |
|||||||
| Output 1 | Output 2 | |||||||
| Upper 8bit of Monitor output 1 (Detection level) | Lower 8bit of Monitor output 1 (Detection level) | |||||||
| Monitor output 2 (Incident light level) 8bit | ||||||||