OMRON 61F-LS (01) Image

FREE ENGLISH OMRON 61F-LS (01) PDF USER GUIDE
FREE ENGLISH OMRON 61F-LS (01) PDF USER MANUAL
FREE ENGLISH OMRON 61F-LS (01) PDF OWNER GUIDE
FREE ENGLISH OMRON 61F-LS (01) PDF OWNER MANUAL
FREE ENGLISH OMRON 61F-LS (01) PDF REFERENCE GUIDE
FREE ENGLISH OMRON 61F-LS (01) PDF INSTRUCTION GUIDE
FREE ENGLISH OMRON 61F-LS (01) PDF REFERENCE MANUAL
FREE ENGLISH OMRON 61F-LS (01) PDF INSTRUCTION MANUAL
FREE ENGLISH OMRON 61F-LS (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD OMRON 61F-LS (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What do the graphic symbols on the OMRON 61F-LS represent?

The graphic symbols on the OMRON 61F-LS represent the following:

Caution on electric shock: A notice that warns of the possibility of electric shock under certain conditions.

Prohibition symbols in general: A general and non-specific notice of prohibition.

No disassembly: A notice of prohibition where disassembly of the equipment may cause injury such as electric shock.

General forced action symbol: A graphic symbol indicating the general action of an unspecified user.


What are the critical safety cautions for operating the OMRON 61F-LS?

Please observe the following safety cautions when operating the OMRON 61F-LS:

Minor injury may be caused by electric shock in rare cases. Turn off the power supply when wiring, and do not touch the terminals while the power is on. Do not touch the product with wet hands.

Slight electric shock, ignition, or equipment failure may occur in rare cases. Do not allow metal, wires, or chips from the installation process to enter the product.

If the contact output is suddenly switched due to a failure in the product, physical damage to the facility, equipment, etc. connected to this product may occur in rare cases. Please be sure to conduct periodic inspections on this product.

Minor injury may be caused by an explosion in rare cases. Do not use this product in the presence of flammable or explosive gases.

Slight electric shock, ignition, or equipment failure may occur in rare cases. Do not disassemble, modify or repair this product, or touch its interior parts.


What are the safety points for handling and storing the OMRON 61F-LS?

Please be sure to thoroughly read and understand the manual before handling the OMRON 61F-LS. The following safety points should be observed:

(1) Do not use or store this product under the following environments:

• Any outdoor environment or one that comes under direct sunlight

• Any environment where it may be splashed with water or oil

• Any environment where it is exposed to the weather

• Any environment where there is significant vibration and impact

• Any environment where the temperature changes are drastic

• Any environment where there is a risk of freezing or condensation

• Any environment where there is dust or corrosive gas (especially sulfide gas, ammonia gas, etc.)

• Any environment where it may be affected by static electricity or noise

• Any environment where there are insects or small animals

• Any environment where it may be splashed with flammable or soluble liquid

• Any environment where it is exposed to sea breeze

(2) Install the product as far away as possible from equipment that generates strong high frequency or surge voltage.

(3) Do not place the product on an unstable surface. It poses a risk of the product falling and becoming damaged, or hitting someone and causing injury.

(4) Do not use the product if it is dropped by mistake, as the inside of the product may be damaged.

(5) Install a switch or circuit breaker and provide an appropriate indication so that the operator can turn OFF the power immediately.

(6) Install the product in the correct orientation.

(7) Use the power supply voltage and load within the specifications and ratings.

(8) Use a power supply that will reach the rated voltage within 1 second after the power is turned ON.

(9) Do not connect anything to unused terminals.

(10) This product should be handled by a specialist with knowledge about electricity.

(11) When using the equipment, make sure to check the wiring before turning on the power.

(12) It may be prone to radio disturbance. Do not use any radio wave receivers near the product.

(13) Use or store the product while keeping the ambient temperature and humidity within the specification range. In particular, do not install the product close to other heating equipment (equipment containing coil or winding). Implement forced cooling if necessary.

(14) It cannot be used for types of oil, etc. that have high specific resistance of liquid and conduct little electricity.

(15) Install the product while ensuring not to apply any load on the main body.


What are the precautions for using the OMRON 61F-LS?

The following are precautions for using the OMRON 61F-LS:

(1) It cannot be used for flammable liquids such as gasoline, kerosene, and heavy oil.

(2) When measuring the insulation resistance, never conduct megger tests between the electrode terminals.

(3) This product requires a certain response time during operation and recovery. Employ caution regarding designs that require subtle timing for sequence control. For details, please check the product specifications for the model to be used.

(4) Do not connect multiple units of this product to the same electrode. For example, a closed circuit (circulating circuit) that passes through the internal circuit of each other is formed when the voltage phase of the 5 V AC power supply is reversed, and this product will operate (malfunction) regardless of the water level by only applying the power supply. Use the electrode rods to be connected to multiple units of this product apart from each other so that they do not suffer mutual interference. However, there is no problem with the sharing of common electrode (the longest electrode).

(5) Use a separator which is sold separately (Model F03-14) to prevent contact if the electrodes come into contact with each other in the liquid.

(6) Make sure that there is no risk of rainwater, etc. accumulating at the connection between the electrodes.

(7) Be sure to ground the common electrode terminal. It can reduce the influence of noise.

(8) Install the socket and DIN rail with screws to prevent loosening. If the screws are loose, vibration, impact, etc. may cause the DIN rail, socket, product main body, or wiring to come off.

(9) When attaching a crimped terminal to a terminal screw, tighten it with the tightening torque within the range from 0.45 to 0.6 N·m.

(10) For stable operation, when using multiple model 61F units in the same tank with a common electrode, please unify them to model 61F-LS series. If unification is not possible, please use the high functionality product.

(16) Check that the output contacts are operating properly. Depending on the operating environment, deterioration of the internal relay may be accelerated and result in malfunction.

(17) Check that the indicator LED is operating properly. Depending on the operating environment, deterioration of the LED may be accelerated and result in indication failure.

(18) Occurrence of chattering may shorten the life of the output relay in this product. Use a circuit and setting that do not cause chattering.

(19) When controlling the contactor opening and closing, be sure to use the self-holding electrode (E2). The contactor may flap under the waviness of the liquid surface and burn the contacts when control is executed only with E1.

(20) Use DIP switch within the following torque value range: Operating Torque: 0.29 N to 4.9 N.

(21) Select the electrodes and electrode holders with consideration of the size of the water tank and the environment inside the water tank (pressure, temperature, controlled liquid, etc.).

(22) Refer to the respective manuals for proper installation of the electrodes and electrode holders.

(23) Keep suspended matters from adhering to the electrodes.

(24) Keep the wiring distance between this product and the electrode holder within the specification range. If the wiring distance is too long, abnormal surge or noise may appear on the electrode circuit and result in abnormal operation.

(25) It becomes safe from surges if a surge killer unit (Model 61F-03B or -04B) is connected to the electrode circuit of this product. Be sure to install it especially in areas where lightning frequently occurs. When surge may enter the power supply, it is safer to connect a commercially available surge killer to the power supply circuit.

(26) To prevent smoke generation and ignition, check the rating of the wires and use the wires that are listed below:

Type of wire Wire material Recommended wire diameter
Single wire/stranded wire Copper 0.25 to 1.5 mm² / AWG24 to AWG16

(27) To clean, use commercially available alcohol and no thinners.

(28) Dispose of this product as industrial waste.


What are the technical specifications for the OMRON 61F-LS?

Item Specifications
Power supply voltage/frequency Model 61F-LS-CP-RA 100 to 240 V AC, 50/60 Hz (alternating current)
Model 61F-LS-CP-RB 24 V AC, 50/60 Hz (alternating current)
Allowable voltage fluctuation range 85 to 110% of the rated voltage
Allowable power supply frequency fluctuation range ± 5 Hz of the rated frequency
Power consumption 3.2 VA or lower
Ambient operating temperature -10 to 70°C (However, there shall be no freezing or condensation.)
Ambient operating humidity Relative humidity 25 to 90% RH
Storage temperature -10 to 70°C (However, there shall be no freezing or condensation.)
Storage humidity Relative humidity 25 to 90% RH
Relay output 250 V AC, 5 A (resistance load (cos φ = 1)), 250 V AC, 1 A (inductive load (cos φ = 0.4))
Voltage between electrodes 5 Vp-p or lower
Startup lock time 3 s after turning on the power supply (The LED blinks during the startup lock time)
Altitude 2000 m or lower
Installation environment Overvoltage category II, Pollution Degree 2

What are the sensitivity and response speed settings for the OMRON 61F-LS-CP-S/-A models?

For the OMRON 61F-LS-CP-S/-A models, sensitivity and response time can be set as follows:

Sensitivity Settings (via DIPSW):

Sensitivity Operating resistance value Reset resistance value Wire length
Standard setting 4kΩ or higher 15kΩ or lower 4km or smaller
Low sensitivity setting 1.3kΩ or higher 4kΩ or lower 4km or smaller
Ultra-Low sensitivity setting 0.5kΩ or higher 2.5kΩ or lower 4km or smaller
High sensitivity setting 70kΩ or higher 300kΩ or lower 50m or smaller
Ultra-high sensitivity setting 200kΩ or higher 500kΩ or lower 30m or smaller

Response Speed Settings:

Response speed Operating time Recovery time
Instantaneous setting 80ms or less 160ms or less
5s setting 5s or less 5s or less

How do you configure the operation settings on the OMRON 61F-LS-CP-S/-A?

The operation settings for the OMRON 61F-LS-CP-S/-A are configured using DIP switches. The factory shipment setting is General sensitivity and Instantaneous response speed.

Symbol Item Specifications
(A) Response speed INSTANT (instantaneous)
5s
(B) Operating resistance Dynamic sensitivity 0.5 kΩ or higher (Ultra-low sensitivity)
1.3 kΩ or higher (Low sensitivity)
4 kΩ or higher (General)
70 kΩ or higher (High sensitivity)
200 kΩ or higher (Ultra-high sensitivity)
Sensitivity *1. N/A functions whether the switch is ON or OFF.

How should the connection sockets be mounted for the OMRON 61F-LS?

Model PF113A: For surface connection sockets, mount it so that the key groove faces downward.

Model PF083A: For surface connection sockets, mount it so that the key groove faces upward.

Model PL11: This is a backside connection socket.


How do you wire the OMRON 61F-LS-CP08-N/-S for water supply and drainage?

When wiring the OMRON 61F-LS-CP08-N/-S, be sure to ground the common electrode (the longest electrode). Wiring is partially different between water supply and drainage.

For water supply:

Connection: Connect A and terminal ② to connect the contactor with coil terminal. (Terminal ③ will be a free terminal.)

Operation: The pump will stop when the water level reaches E1 (operation display “ON”), and start at E2 or lower (operation display “OFF”).

For drainage:

Connection: Connect A and terminal ③ to connect the contactor with coil terminal. (Terminal ② will be a free terminal.)

Operation: The pump will start when the water level reaches E1 (operation display “ON”), and stop at E2 or lower (operation display “OFF”).


How do you wire the OMRON 61F-LS-CP11-N/-S for water supply and drainage?

When wiring the OMRON 61F-LS-CP11-N/-S, be sure to ground the common electrode (the longest electrode). Wiring is partially different between water supply and drainage.

For water supply:

Connection: Connect A and terminal [1] to connect the contactor with coil terminal. (Terminal [11] will be a free terminal.)

Operation: The pump will stop when the water level reaches E1 (operation display “ON”), and start at E2 or lower (operation display “OFF”).

For drainage:

Connection: Connect A and terminal [11] to connect the contactor with coil terminal. (Terminal [1] will be a free terminal.)

Operation: The pump will start when the water level reaches E1 (operation display “ON”), and stop at E2 or lower (operation display “OFF”).


What is the operational difference between the OMRON 61F-LS initial operation (-A) and sequential operation (-N/-S) models?

For the OMRON 61F-LS, while the operation after turning on the power is identical, the contacts when the power is turned OFF are different between the initial operation model (Model 61F-LS-CP-A) and the sequential operation model (Model 61F-LS-CP-N/-S).

The following contacts are used when the power is turned OFF:

Sequential operation model (-N/-S):

• At CP11, 6-7 and 10-11 are open

• At CP08, 3-4 is open

Initial operation model (-A):

• At CP11, 6-8 and 10-1 are open

• At CP08, 2-4 is open

Please select one according to your environment of use.


CLICK HERE TO DOWNLOAD OMRON 61F-LS (01) PDF MANUAL


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.