What are the BTU specifications and orifice sizes for the MONESSEN AVFL48NIF?
The input ratings for the MONESSEN AVFL48NIF are based on elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level.
| Model | Fuel Type | Maximum Input BTU/h | Minimum Input BTU/h | Orifice Size (DMS) |
|---|---|---|---|---|
| MONESSEN AVFL48NIF | Natural Gas (NG) | 39,000 | 27,500 | .120 (#31) |
| MONESSEN AVFL48NIF | Propane (LP) | 38,000 | 31,000 | .076 (#48) |
What should I do if I smell gas near my MONESSEN AVFL48NIF?
Failure to follow safety warnings exactly could result in serious injury, death, or property damage. If you smell gas:
1. DO NOT try to light any appliance.
2. DO NOT touch any electrical switch.
3. DO NOT use any phone in your building.
4. Leave the building immediately.
5. Immediately call your gas supplier from a neighbor’s phone and follow their instructions.
6. If you cannot reach your gas supplier, call the fire department.
What are the safety clearance requirements for the MONESSEN AVFL48NIF?
High temperatures may ignite clothing or other flammable materials. Follow these guidelines for the MONESSEN AVFL48NIF:
Maintain a clear space of at least 3 feet in front of the appliance.
Clothing, furniture, draperies, and other flammable materials must not be placed on or near the appliance.
Avoid placing candles, electronics, and other heat-sensitive objects on the mantel or hearth as heat may damage them.
Do not install this appliance in a bedroom or bathroom.
Young children should be carefully supervised. A physical barrier, such as an adjustable safety gate, is recommended to keep toddlers, young children, and pets away from hot surfaces.
How do I perform the initial break-in procedure for the MONESSEN AVFL48NIF?
During manufacturing, various components are treated with oils, films, or bonding agents. These may produce annoying smoke and smells during initial operation. Follow these steps for the MONESSEN AVFL48NIF:
1. Run the appliance continuously on high for three to four hours.
2. Open windows for air circulation during this period to allow odors to dissipate.
3. Turn the appliance off and allow it to completely cool.
4. This process cures the materials used to manufacture the appliance. Any remaining odors after this period will be slight and will disappear with continued use.
How do I operate the MONESSEN AVFL48NIF using battery power during a power outage?
The MONESSEN AVFL48NIF features a battery backup system that allows it to operate during a power outage. Note that some functionality, such as remote control and lights, may be lost. Follow these steps for DC operation:
1. Access the control cavity. Ensure the unit is off and cool. Lift the barrier screen and remove internal media (logs, stone, crushed glass) and the deflection glass panel.
2. Remove the two screws securing the burner assembly. Lift the burner assembly and place it against the engine supports provided.
3. Locate the battery tray and insert four AA cell batteries. Ensure battery polarity is correct to prevent module damage.
4. Turn the appliance on using the wall switch. To preserve battery life, do not use HI/LO flame or thermostat options.
5. To return to AC power after electricity is restored, toggle the switch to OFF and remove the batteries from the battery tray.
What are the functions of the IFT2-ECM selector switch on the MONESSEN AVFL48NIF?
The Electronic Control Module (IFT2-ECM) has a three-position switch. When changing positions, pause in each position for 1-2 seconds.
OFF Position: The appliance will not respond to any commands from remote controls or mobile apps. Use this position during installation, service, or fuel conversion.
ON Position: The appliance will ignite and run continuously at the HIGH flame setting. No adjustment is possible. A safety feature will automatically shut down the fireplace after 9 hours of continuous operation in this position.
REMOTE Position: This allows operation from remote controls or the mobile app. A safety feature will automatically shut down the fireplace after 9 hours of continuous operation without receiving a command.
How can I manually shut off the MONESSEN AVFL48NIF in an emergency?
If the remote or wall switch malfunctions, you can manually shut down the MONESSEN AVFL48NIF using these methods:
Method 1: Turn off the reset switch located in the front face of the appliance.
Method 2: If no backup batteries are installed, unplug the appliance from the electrical source.
Method 3: Locate the house circuit breaker for the appliance and turn it off.
Caution: Appliance surfaces are hot. Use care and wear gloves when accessing components inside the unit.
What maintenance tasks should be performed on the MONESSEN AVFL48NIF?
Regular maintenance ensures many years of trouble-free service. Below is a summary of tasks for the MONESSEN AVFL48NIF:
Annually (Homeowner): Inspect and clean the surrounds. Assess the condition of the screen and replace if necessary. Vacuum and dust all surfaces.
Seasonally (Homeowner): Verify remote control operation and replace batteries as needed. Remove batteries if the appliance will not be used for an extended period.
Annually (Qualified Service Technician): Perform pilot inspection and cleaning, log/glass media inspection, firebox inspection, and burner ignition and operation checks.
Why does the MONESSEN AVFL48NIF release an odor or make metallic noises?
Odor: New appliances release odors from manufacturing oils and finishing materials during the first several hours. Odors can also be caused by dust, pet dander, or room sprays collecting on the burner. Have a technician clean the unit prior to the first use of each season.
Metallic Noise: This is normal and is caused by metal expanding and contracting as it heats up and cools down. It does not affect the operation or longevity of the appliance.
What do the IFT2-ECM LED error codes mean on the MONESSEN AVFL48NIF?
If the MONESSEN AVFL48NIF is in a lock-out condition, the LED status indicator will blink a RED/GREEN error code:
| LED Error Code | Description |
|---|---|
| 2 Red: 1 Green | Error Pilot Flame: Pilot valve solenoid not detected or open pilot flame coil. |
| 2 Red: 2 Green | Ignition feedback signal error, spark coil failure, or low-impedance short. |
| 3 Red: 1 Green | Appliance Safely Disabled: Pilot sparks for 90 seconds, but no flame rectification. |
| 4 Red: 1 Green | 110VAC power is connected to the wall switch. |
| 6 Red: 1 Green | Error ODS: Requires moving switch to OFF for 3 seconds before moving back to REMOTE. |
| 8 Red: 1 Green | ECM error. |
Troubleshooting: What if the MONESSEN AVFL48NIF remote control does not respond?
Check the following if the remote control for your MONESSEN AVFL48NIF is not working:
1. Verify batteries are functional and installed correctly in the remote.
2. Check if the remote is in Child Lock mode; if so, disengage it.
3. Ensure buttons are being pressed firmly for one to two seconds.
4. Ensure the control module selector switch is set to REMOTE.
5. If the touchscreen has lost calibration, it may need to be re-calibrated by a dealer.
6. If the remote displays “Replace remote batteries,” install new batteries immediately.