How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What is the AE-200 Update Tool for the MITSUBISHI ELECTRIC EW-50E?
The Update Tool is a software tool designed to update the software of all MITSUBISHI ELECTRIC EW-50E controllers connected in the air conditioning control system simultaneously. It allows for updating a maximum of 50 controllers at once from a single PC.
What are the PC requirements for using the MITSUBISHI ELECTRIC EW-50E Update Tool?
| Item | Requirements |
|---|---|
| CPU | 1 GHz or better (at least 2 GHz recommended) |
| Memory | 2 GB or better |
| Screen resolution | 1024 x 768 or better |
| OS | Microsoft® Windows® 11 (64bit) *1 Microsoft® Windows® 10 (64bit) *1 Microsoft® Windows® 8.1 (64bit) *1 Must meet the minimum requirements of the OS |
| Internal LAN port or LAN card | 100 BASE-TX or better |
| Pointing device | Mouse, etc. |
*1 Verified to work on the Pro edition.
.NET Framework 4.8 is required. When installing the Update Tool, the page will jump to the download site if .NET Framework 4.8 or later is not installed.
Note: The use of the latest version of the OS is recommended.
Are there any special connection requirements for the MITSUBISHI ELECTRIC EW-50E via LAN?
Yes. When connecting the MITSUBISHI ELECTRIC EW-50E via a LAN, you must use the “LAN1” port.
What are the system restrictions when updating my MITSUBISHI ELECTRIC EW-50E?
Please be aware of the following restrictions when using the Update Tool for your MITSUBISHI ELECTRIC EW-50E:
• The AE-200 Update Tool is exclusively for AE-200/AE-50/EW-50 models. Do not use it for other products.
• The software cannot be downgraded to an earlier version.
• A maximum of 50 controllers can be updated at the same time.
• Communication between the MITSUBISHI ELECTRIC EW-50E and the air conditioning units will stop during the update. The unit will continue to operate and can be controlled by local remote controllers, but a communication error may appear.
• Mr. Slim indoor units or systems without local remote controllers may detect a communication error and stop abnormally.
• Up to 60 minutes of energy management and billing function data will not be recorded during the update.
• If the Pulse Input (PI) function of a MITSUBISHI ELECTRIC EW-50E is used, any pulses input during the software update will not be counted.
• It is important to record the operation status of the air conditioning units before the update and check them again after the update is complete, manually operating them as necessary.
• Functions like scheduled operations, billing, Peak Cut control, and energy management will be disabled during the update. Check the settings of these functions beforehand.
Are there times when I should avoid updating my MITSUBISHI ELECTRIC EW-50E due to specific functions being in use?
Yes. If the functions in the table below are used with your MITSUBISHI ELECTRIC EW-50E, avoid updating the software during the indicated time period.
| Function in use | Time period in which the update is prohibited |
|---|---|
| Electricity charge apportioning function (with Charge Calculation Tool) | AM 5:00 – 5:10 |
| Electricity charge apportioning function (with TG-2000A) | AM 4:05 – 4:35 |
| Malfunction log backup (with TG-2000A) | AM 0:05 – 0:15 |
| Peak Cut data backup (with TG-2000A) | AM 2:00 – 2:10 |
| Measurement trend data backup (with PI controller, AI controller, or TG-2000A) | AM 1:05 – 1:15 |
How do I install the Update Tool for my MITSUBISHI ELECTRIC EW-50E?
Before you begin, ensure that .NET Framework version 4.8 is installed. You can check this in the Control Panel under “Program and Features”.
1. Double-click the downloaded “AE-200 UpdateTool_V***.msi” file.
2. If a “Security Warning” message appears, click [Run].
3. When the “Setup Wizard” screen appears, click [Next].
4. Read the “License Agreement”, select [I Agree], and click [Next].
5. On the “Select Installation Folder” screen, choose the destination folder and click [Next]. To allow all PC users access to the tool, ensure the [Everyone] checkbox is selected.
6. When the “Confirm Installation” screen appears, click [Next].
7. The Update Tool will now be installed.
8. Once the installation is complete, click [Close].
How do I set my PC’s IP address to update the MITSUBISHI ELECTRIC EW-50E?
To send data from the Update Tool to your MITSUBISHI ELECTRIC EW-50E, you must set your PC’s IP address to be on the same network. For example, if the controller’s IP is 192.168.11.1, your PC’s IP could be 192.168.11.150. Consult your system administrator if connecting to an existing LAN.
1. Open the Control Panel on your PC.
2. Click [Network and Sharing Center] > [Change adapter settings]. Double-click the [Ethernet] icon.
3. In the “Ethernet status” window, click [Properties].
4. Select [Internet Protocol Version 4 (TCP/IPv4)] and click [Properties].
5. In the Properties window, select the radio button for [Use the following IP address].
6. Enter the PC’s IP address (e.g., 192.168.11.150).
7. Enter the subnet mask (e.g., 255.255.255.0, unless specified otherwise).
8. Enter the gateway address if necessary.
9. Click [OK] or [Close] to close all windows and save the settings.
Important: Always consult the system administrator to decide the IP, subnet mask, and gateway addresses, and make a note of the original settings before changing them.
How do I install the required .NET Framework for the MITSUBISHI ELECTRIC EW-50E Update Tool?
If .NET Framework 4.8 is not already installed on your PC, you will need to download and install it from the official Microsoft download page. If your system is not connected to the Internet, you will need to download the offline installer beforehand from an internet-connected device and transfer it to the target PC.
What are the functions of the main screen in the Update Tool for my MITSUBISHI ELECTRIC EW-50E?
| Function | Operation method | Description |
|---|---|---|
| Menu bar | Operations such as loading a TXT file with IP addresses, saving entered IP addresses, exiting the tool, and checking version information. | Provides access to file operations and help information. |
| Update file selection | Select the update file for the centralized controller. | Allows you to browse for and select the specific .dat update file. |
| IP address setting | The area where settings of the IP address of the centralized controller to be updated are made. | You can manually enter IP addresses or load them from a file here. |
| Centralized controller system information | The system information of a given centralized controller is displayed (Model name, Version, Serial No.). | Displays details of the controller after a successful data acquisition. |
| Centralized controller status | The status regarding the update of a given centralized controller is displayed. | Shows the current status of each controller (e.g., “Data acquisition succeeded”, “Updating…”). |
| [Acquire data] | Click to acquire the system information of the centralized controllers whose IP addresses are entered in the IP address setting area. | Communicates with the controllers to check their current status and version. |
| [Update] | Click to update the centralized controllers whose IP addresses are entered in the IP address setting area. | Starts the software update process for the selected controllers. |
Note: Up to 50 centralized controllers can be updated at the same time.
How do I use the menu bar in the MITSUBISHI ELECTRIC EW-50E Update Tool?
The menu bar contains two main menus: File and Help.
File Menu:
• [Open]: Click [File] > [Open] to load a TXT file containing the destination IP addresses of your MITSUBISHI ELECTRIC EW-50E controllers.
• [Save]: Click [File] > [Save] to save the IP addresses that are currently entered in the IP address setting area to a TXT file on your PC.
• [Exit]: Click [File] > [Exit] to close the Update Tool.
Help Menu:
• [About]: Click [Help] > [About] to display the current version information of the Update Tool software.
How do I input the IP addresses of my MITSUBISHI ELECTRIC EW-50E controllers?
There are two ways to input the IP addresses:
1. Inputting IP addresses directly:
Enter the IP address of each MITSUBISHI ELECTRIC EW-50E to be updated directly into a row in the “Destination IP address” column on the main screen.
Important: Enter the IP address in one-byte characters in the format [XXX.XXX.XXX.XXX], where XXX is an integer between 0 and 255. Do not enter any other characters, including tabs or spaces.
2. Loading IP addresses from a TXT file:
1. Using Notepad or a similar text editor, create a file containing the IP addresses of the centralized controllers. Enter one IP address per line.
2. In the Update Tool, click [File] > [Open].
3. A file selection screen will appear. Select the TXT file you created and click [Open].
4. The IP addresses from the file will be loaded and displayed in the “Destination IP address” column.
Note: You can load up to 50 IP addresses. A blank line in the TXT file will appear as a blank line in the tool.
How do I check the versions of my MITSUBISHI ELECTRIC EW-50E controllers?
1. After inputting the IP addresses for your MITSUBISHI ELECTRIC EW-50E controllers, click the [Acquire data] button.
2. The tool will communicate with each controller. Once successful, the “Status” column will display “Data acquisition succeeded”, and the “Model name”, “Version”, and “Serial No.” columns will be populated with the information for each controller.
What do the different “Status” messages mean after acquiring data from my MITSUBISHI ELECTRIC EW-50E?
| Display information in the “Status” column | Explanation |
|---|---|
| Acquiring data… | The centralized controller data are being acquired. The message will appear in black. |
| Data acquisition succeeded | The centralized controller data have been successfully acquired. The message will appear in black. The model name, version, and serial number will be displayed. |
| Data acquisition failed | The centralized controller data have failed to be acquired. The message will appear in red. |
| Invalid IP address | The IP address entered is not in the correct format. The message will appear in red. |
| IP addresses overlap | The same IP address has been entered more than once. The message will appear in red. |
| The equipment is not applicable for update. | Data was acquired from equipment that is not a target for this update tool. The message will appear in red, and the equipment details will be displayed. |
How do I perform the update on my MITSUBISHI ELECTRIC EW-50E?
1. Select the update file: In the “Update file selection” section, click [Browse…] next to “AE-50/EW-50 update file”. Select the correct update file (“AE50_FW####_****.dat”) and click [Open]. The file path will appear in the text box.
2. Start the update: Click the [Update] button. The “Authentication information input” screen will appear.
3. Enter credentials: For the first controller (No. 1), enter the ID and password for its initial settings. For subsequent controllers, if they use the same ID and password, you can check the “Same as No. 1” checkbox. If they have different credentials, enter them manually.
4. Confirm authentication: Click [OK]. The authentication screen will close, and the update process will begin.
5. Monitor the status: The “Status” column on the main screen will show the progress for each MITSUBISHI ELECTRIC EW-50E controller (e.g., “Updating…”, “Update completed”).
Important: During the update process, do not close the application, disconnect the LAN cable, or turn off the power to the MITSUBISHI ELECTRIC EW-50E.
What do the different update “Status” messages mean for my MITSUBISHI ELECTRIC EW-50E?
During the update process, the “Status” column will display the following messages in a typical sequence:
| Display information in the “Status” column | Explanation | Display order |
|---|---|---|
| Authentication succeeded | The centralized controller authentication has been successfully completed. The message will appear in black. | 1 |
| Authentication failed | The centralized controller authentication has failed. The message will appear in red. | |
| Communication failed | The centralized controller communication has failed. The message will appear in red. | |
| Already updated | The centralized controller is already updated. The message will appear in red. | |
| Updating… | The centralized controller is being updated. The message will appear in black. | 2 |
| Update completed | The centralized controller update has been successfully completed. The message will appear in black. | 3 |
| Update failed | The centralized controller update has failed. The message will appear in red. |
How long does it take to update MITSUBISHI ELECTRIC EW-50E controllers?
The approximate time required for the update varies with the number of controllers and the software version.
| Number of centralized controllers to be updated | Time required for update [min] | |
|---|---|---|
| Ver. 7.24 or earlier | Ver. 7.31 or later | |
| 4 | 9 | 7 |
| 10 | 15 | 10 |
| 20 | 25 | 15 |
| 40 | 45 | 25 |
| 50 | 55 | 30 |
How do I save the list of IP addresses for my MITSUBISHI ELECTRIC EW-50E?
1. Click [File] > [Save] from the menu bar.
2. A “Save As” screen will appear. Enter a file name for your list of IP addresses and click [Save].
3. A confirmation window will appear stating “The destination IP addresses have been saved.” Click OK.
How do I troubleshoot common errors with the MITSUBISHI ELECTRIC EW-50E Update Tool?
| Problem | Possible cause | Solution |
|---|---|---|
| Error “File read failed. Check the data in the file.” when loading a TXT file. | The TXT file is not created according to the specified format. | Check if the TXT file is created with one IP address per line and in the correct format. Re-create the file if necessary. |
| Error “This file is not an update file for AE-50/EW-50.” when selecting an update file. | A wrong file is selected. | Check that the name of the selected file is “AE50_FW####_****.dat” (where #### is the software version). Then, re-select the correct file. |
| “Data acquisition failed” appears in the Status column. | The IP address of the controller is different from the one entered. The LAN connection with the controller is not established. |
Check if the IP address of the centralized controller is correct and re-enter it. Check for proper LAN connection between the PC and the controller. |
| “Invalid IP address” appears in the Status column. | The IP address is not entered according to the specified format. | Check if the IP address is entered in the format XXX.XXX.XXX.XXX and correct it. |
| “IP addresses overlap” appears in the Status column. | The same IP address is entered more than once. | Check the IP addresses of the controllers in error, and re-enter the correct IP addresses. |
| Error “Check that the data acquisition of all centralized controllers has succeeded.” when clicking [Update]. | Data acquisition has not been completed for all listed controllers. | Check the “Status” column to find controllers whose data have not been acquired. Click [Acquire data] to complete the process. |
| Error “AE-50/EW-50 update file is not selected.” when clicking [Update]. | The update file for AE-50/EW-50 has not been selected. | Click [Browse…] for AE-50/EW-50 and select the correct update file. |
| Error “The version of the selected update file is older than the version of AE-50/EW-50.” when clicking [Update]. | The selected update file is for an older software version than what is currently installed. | Click [Browse…] for AE-50/EW-50 and select the update file whose version is later than the current version. |
| Error “The versions of the update file for AE-200 and the update file for AE-50/EW-50 do not match.” when clicking [Update]. | The software versions of the selected update files for the different controller models are not compatible with each other. | Check the versions of the update files for all controller models. Then, re-select the update files so that their versions match. |
| Error “Communication or authentication failed. Check the status.” during update. | The LAN connection was cut off. The entered ID and password are wrong. |
Check for proper LAN connection between the PC and the controller in error. Re-enter the correct ID and password for the controller in error. |
| “Update failed” appears in the Status column. | The LAN connection was cut off during the update. A communication failure occurred. |
Check for proper LAN connection. Click [Acquire data] on the main screen to check the controller’s version. If it has not been updated, try the update again. |
CLICK HERE TO DOWNLOAD MITSUBISHI ELECTRIC EW-50E (01) PDF DOCUMENT