What should I check before operating my FRIEDRICH CHILL+ (CHILLPLUS) EP08?

Before operating your FRIEDRICH CHILL+ (CHILLPLUS) EP08, ensure the following:

Wiring: Make sure the wiring is adequate for your unit. If you have fuses, they should be the time delay type. The amperage rating of the circuit breaker or time delay fuse should not exceed the amp rating of the unit.

Extension Cord: DO NOT use an extension cord. The cord provided with the unit is designed to carry the proper amount of electrical power.

Receptacle Compatibility: Ensure that the wall receptacle is compatible with the three-prong plug provided. This ensures proper grounding. If you have a two-prong receptacle, it must be replaced by a certified electrician with a properly grounded circuit that meets all national and local codes.


How do I test the power cord on my FRIEDRICH CHILL+ (CHILLPLUS) EP08?

The power cord of your FRIEDRICH CHILL+ (CHILLPLUS) EP08 may include a current interrupter device with a test and reset button on the plug case. You should test this device periodically by following these steps:

1. First, press the TEST button.

2. Then, press the RESET button.

If the TEST button does not trip, or if the RESET button does not stay engaged, you should discontinue use of the air conditioner and contact a qualified service technician.


How can I get the best cooling performance and energy efficiency from my FRIEDRICH CHILL+ (CHILLPLUS) EP08?

To ensure optimal performance and efficiency for your FRIEDRICH CHILL+ (CHILLPLUS) EP08, follow these guidelines:

Keep the filter clean: Clean the filter regularly to keep your air conditioner in top performing condition. Instructions for removing and cleaning the filter are available in the manual.

Provide good air flow: Ensure that the airflow to and from the unit is clear. The unit puts air out at the side and takes air in at the left. It is critical that airflow is not blocked, including the exterior portion of the unit.

Unit Placement: For better efficiency, place the air conditioner in a window or wall that is shaded by a tree or another building. Using drapes or blinds on the sunny side of the dwelling will also improve efficiency.

Insulation: Good insulation helps maintain comfort levels. Ensure doors have weather stripping and caulk around doors and windows.


How do I use the controls on my FRIEDRICH CHILL+ (CHILLPLUS) EP08?

1. POWER: Operation begins when this button is pressed and stops when you press the button again.

2. AUTO SWING: This button automatically controls the air flow direction.

3. TEMPERATURE CONTROL: The thermostat monitors room temperature to maintain the desired temperature. It can be set between 60°F and 86°F (16°C and 30°C).

4. CHECK FILTER & FILTER RESET: The ‘Check Filter’ LED will light up after approximately 250 hours of operation, indicating the filter needs to be cleaned. To reset and turn off the light, press the ‘Temp ∨’ and ‘∧’ buttons together on the unit’s control panel (not the remote control).

5. FAN SPEED SELECTOR: For increased power while cooling, select a higher fan speed. There are 2 speeds: Low and High.

6. OPERATION MODE SELECTOR: Push the ‘Mode’ button to rotate between different modes.

MoneySaver: The fan will stop when the compressor stops cooling and will turn on approximately every 3 minutes to sample the room air to determine if more cooling is needed.

Cool: The fan runs continually for normal cooling operation.

Fan Only: This is for fan-only operation.

Heat: The fan runs continually for normal heat operation.

7. ON/OFF TIMER:

ON: If the unit is off, use the Timer to set the number of hours before the unit starts. Push the Timer button to advance the setting from 1hr up to 24hrs maximum.

OFF: If the unit is running, use the Timer to set the number of hours until it shuts off. Push the Timer button to advance the setting from 1hr up to 24hrs maximum.

Timer Clear: On the remote control, the ‘Timer Clear’ button will cancel the timer setting.

8. REMOTE CONTROL SENSOR: This sensor receives the signal from the remote controller.


How do I insert or replace the batteries in the remote control for my FRIEDRICH CHILL+ (CHILLPLUS) EP08?

1. Push out the cover on the back of the remote control with your thumb.

2. Pay attention to polarity and insert two new AAA 1.5V batteries.

3. Reattach the cover.

NOTE: Do not use rechargeable batteries and make sure both batteries are new. To prevent discharge, remove the batteries if the air conditioner will not be used for an extended period. Keep the remote control away from extremely hot or humid places, and ensure the remote sensor on the unit is not exposed to direct sunlight for optimal operation.


How do I adjust the air flow direction on my FRIEDRICH CHILL+ (CHILLPLUS) EP08?

You can adjust the airflow by changing the direction of the air conditioner’s louvers.

Vent Control: For maximum cooling efficiency, CLOSE the vent. This allows internal air circulation. OPEN the vent to discharge stale air. Before using the ventilation feature, position the lever by first pulling down part A to be horizontal with part B.

Adjusting Horizontal Air Flow Direction: Adjusting the vertical louvers left and right will change the horizontal airflow.

Adjusting Vertical Air Flow Direction: Adjusting the horizontal louver up and down will change the vertical airflow. The louver can be adjusted by pressing in at the top or bottom of the horizontal louver.


How do I remove and clean the air filter on my FRIEDRICH CHILL+ (CHILLPLUS) EP08?

The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks to maintain optimal performance. Before cleaning, turn the power off and unplug the power plug.

1. Open the inlet grille upward by pulling out the bottom of the inlet grille.

2. Remove the air filter from the front grille assembly by pulling the air filter up slightly.

3. Wash the filter using lukewarm water below 104°F (40°C).

4. Gently shake the excess water from the filter. When completely dry, replace the filter.


What should I do if water is overflowing from the base pan of my FRIEDRICH CHILL+ (CHILLPLUS) EP08?

The base pan may overflow due to high humidity, which is normal. To drain the excess water, remove the drain cap from the back of the unit and secure the drainpipe. When pressing the drainpipe into place, apply force in the direction away from the fins to avoid injury.


What are some important safety precautions for using my FRIEDRICH CHILL+ (CHILLPLUS) EP08?

To prevent injury and property damage, always follow these instructions:

Power Plug:

• Plug in the power plug properly to avoid electric shock or fire.

• Do not operate or stop the unit by inserting or pulling out the power plug, as this can cause electric shock or fire.

Power Cord:

• Do not damage or use an unspecified power cord. If the cord is damaged, it must be replaced by a certified service agent.

• Do not modify the power cord length.

Operation:

• Do not operate with wet hands or in a damp environment to avoid electric shock.

• Do not direct air flow directly at room occupants to prevent health problems.

• Do not operate the unit without the air filter or when the front intake grille is removed.

• Do not put a pet or house plant where it will be exposed to direct air flow.

• Do not use the air conditioner for special purposes, such as preserving precision devices, food, pets, or art objects.

Cleaning and Maintenance:

• For inner cleaning, contact an Authorized Service Center. Do not use harsh detergents.

• When removing the air filter, do not touch the metal parts of the unit as they are sharp.

• Do not clean the air conditioner with water, as this can cause an electric shock.

• When cleaning the unit, switch it off and unplug it first.

Handling:

• The edges of the case can be sharp. Use caution and heavy gloves if necessary. Do not allow the case to slide against your skin.

Remote Batteries:

• If liquid from the batteries gets on your skin or clothes, wash it well with clean water. Do not use the remote if batteries have leaked.

• If you ingest liquid from the batteries, brush your teeth and see a doctor.


What are some normal operations for my FRIEDRICH CHILL+ (CHILLPLUS) EP08 that I should be aware of?

The following are considered normal operation for your air conditioner:

• You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This feature helps remove moisture and improve efficiency.

• You may hear the thermostat click when the compressor cycles on and off.

• Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

• The fan may run even when the compressor does not.

• Your air conditioner is designed to cool in warm weather when the outside temperature is above 60°F (16°C) and below 109°F (43°C).


What should I do if my FRIEDRICH CHILL+ (CHILLPLUS) EP08 does not start?

Possible Causes What To Do
The air conditioner is unplugged. Make sure the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped. Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
Power failure. If power failure occurs, turn the mode control to Off. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
The current interrupter device was tripped on the power cord. Press the RESET button located on the power cord plug. If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

What should I do if my FRIEDRICH CHILL+ (CHILLPLUS) EP08 does not cool as it should?

Possible Causes What To Do
Airflow is restricted. Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
The THERMOSTAT may not be set high enough. Push temperature setting button to coolest temperature setting of 60°F.
The air filter is dirty. Clean the filter at least every 2 weeks. See the operating instructions section.
The room may have been hot. When the air conditioner is first turned on you need to allow time for the room to cool down.
Cold air is escaping. Check for open furnace floor registers and cold air returns. Set the air conditioner’s vent to the closed position.
Cooling coils have iced up. See “Air Conditioner Freezing Up” troubleshooting.

Why is my FRIEDRICH CHILL+ (CHILLPLUS) EP08 freezing up and what should I do?

Possible Cause What To Do
Ice blocks the air flow and stops the air conditioner from cooling the room. Set the mode control on high fan until the ice thaws out. This may indicate a bigger problem.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD FRIEDRICH CHILL+ (CHILLPLUS) EP08 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.