What is the description and function of the FIREYE MP561 Programmer Module?

The FIREYE MP561 Programmer Module is used with the Fireye Modular M-Series II control. It features a plug-in design for easy installation. The module is equipped with LED indicator lights to indicate the operating status of the control. It specifically includes a series of dipswitches to select Purge Timing, Pilot Trial for Ignition (PTFI) Timing, and Recycle or Non-Recycle operation. Additionally, a “check-run” switch is provided to assist in testing the size and stabilization of the pilot.


How do I install the FIREYE MP561 into the chassis?

The FIREYE MP561 is installed in the chassis using the following steps:

1. Grab hold of the programmer module by the ridged finger grips on the side of the module.

2. Align the module with the guide slots on the opening farthest from the transformer.

3. Insert the module into the pin connectors.

The module is designed to fit in the proper slot only. DO NOT FORCE THEM.


What safety step must be taken before proceeding with the installation or removal of the FIREYE MP561?

WARNING: Remove power from the control and remove the control from its wiring base before proceeding.


What are the specific operational characteristics and settings for the FIREYE MP561?

Part Number Description
FIREYE MP561 Selectable purge timing, pilot-trial-for-ignition timing, and recycle/non-recycle operation. 10 second main flame trial-for-ignition, check-run switch.

How is the Flame Failure Response Time (FFRT) determined for the FIREYE MP561?

Flame Failure Response Time (FFRT) is determined by the selection of the amplifier module, not the programmer module itself. Test jacks are provided on the flame amplifier module to permit flame signal measurement during operation.


Where is the fuse located on the FIREYE MP561 and how do I replace it?

The FIREYE MP561 is designed with a field-replaceable fuse located on the printed circuit board near the connectors. The fuse will open as a result of an overload condition on terminals 3, 4, or 5.

To replace the fuse:

1. Remove the fuse using a small screwdriver.

2. Install a Fireye replacement fuse (P/N 23-176) or equivalent 2AG, 8 amp fuse (e.g. Littlefuse #225008).

Note: In programmers used with the MC230 and MC230R Chassis, use replacement fuse P/N 23-183 or equivalent (3.5 amp, 2AG, SLO-BLO) Littlefuse #22903.5.


What agency approvals does the FIREYE MP561 possess?

Model UL CSA FM EN298
FIREYE MP561 Yes Yes Yes No

Note: Approvals do not apply to MC230 and MC230R Chassis and associated programmers.