EXTREME 5120-44X-4Y-2C-AC-R (01) Image

FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF DOCUMENT.
FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF USER GUIDE.
FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF USER MANUAL.
FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF OWNER GUIDE.
FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF OWNER MANUAL.
FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF REFERENCE GUIDE.
FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF REFERENCE MANUAL.
FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH EXTREME 5120-44X-4Y-2C-AC-R (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD EXTREME 5120-44X-4Y-2C-AC-R (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What tools are required to set up the EXTREME 5120-44X-4Y-2C-AC-R?

The necessary tools for setting up the EXTREME 5120-44X-4Y-2C-AC-R are:

1. #2 Phillips screwdriver (a magnetic screwdriver is recommended)

2. ESD-protective wrist strap


What are the installation site requirements for the EXTREME 5120-44X-4Y-2C-AC-R?

The installation site for the EXTREME 5120-44X-4Y-2C-AC-R must meet the following requirements:

• Appropriately grounded power receptacles located within 1.8 m (6 ft.)

• A readily accessible device for disconnecting power, such as a breaker or master switch

• Network cabling within reach

• Ensure that the vent openings on the front panel and the rear fan modules are not blocked for proper ventilation

• Temperature between 0°C (32°F) and 50°C (122°F), or as noted in “Operating Conditions”, with fluctuations of less than 10°C (18°F) per hour.


What items should be included in the box with the EXTREME 5120-44X-4Y-2C-AC-R?

After unpacking the EXTREME 5120-44X-4Y-2C-AC-R, you should verify that all of the following components are included:

1. Switch

2. Quick reference guide

3. Accessory box

4. Rack mount ears (2), accessory bag: Rail screws (12), rack screws (6), rack nuts (6)

Note: Console cables can be ordered separately.


How do I install the EXTREME 5120-44X-4Y-2C-AC-R in a two-post rack?

The EXTREME 5120-44X-4Y-2C-AC-R can be installed in a standard 19-inch equipment rack. To install it in a two-post rack, follow these steps:

1. Attach a mounting bracket to each side of the switch. You can attach the brackets at the front of the switch (flush-mount or mid-mount) or at the middle of the switch.

2. Secure the brackets to the rack posts using rack-mounting screws and nuts that are appropriate for the rack (provided). The switch can be mounted to the two front posts or the two rear posts as shown.

Note: The two-post mounting kit accommodates rack posts 3 inches or 6 inches wide. The rack mount kit supports flush-mounting and mid-mounting.


How do I connect the EXTREME 5120-44X-4Y-2C-AC-R to a power source?

To connect the EXTREME 5120-44X-4Y-2C-AC-R to a primary power source:

1. Connect the AC power cord to the AC power input socket on the power supply and an AC power outlet.

2. When power is connected, verify that the switch’s PWR LED turns green.

Note: Installing the system as described meets protective earth grounding requirements. However, in some cases, an alternative grounding method may be necessary. In these cases, a 14 AWG wire can be connected between the grounding lug on the chassis and a nearby building ground point.


What is the initial software configuration process for the EXTREME 5120-44X-4Y-2C-AC-R?

You should upgrade to a generally available (GA) version of the software before using the EXTREME 5120-44X-4Y-2C-AC-R. Switch Engine is the default operating system (OS) for the 5120 Series. To connect the switch to the network, upgrade it, and configure it for use, follow the steps in the Extreme 5120 Hardware Installation Guide.


What are the hardware components of the EXTREME 5120-44X-4Y-2C-AC-R series switches?

The hardware components are as follows:

Front Panel Components:

1. 1Gb/10Gb SFP+ ports (or 1Gb/10GBase-T non-PoE ports for 5120-24XT-4Y)

2. 10Gb/25Gb SFP28 ports

3. Micro-B USB serial console port

4. System LEDs

5. Mode button

6. USB Type A port

7. RJ-45 serial console port

8. 100/1000BASE-T out-of-band management port

9. 100Gb QSFP28 uplink ports

Rear Panel Components:

1. Modular AC power supplies

2. Grounding lug

3. Fan modules

4. Filler panels


What are the operating conditions for the EXTREME 5120-44X-4Y-2C-AC-R?

Operating Temperature: 0°C (32°F) to 50°C (122°F) up to 3000 m (10,000 ft), front-to-back and back-to-front airflow

One fan failure:

For the 5120-44X-4Y-2C model (which includes the EXTREME 5120-44X-4Y-2C-AC-R):

• 0°C (32°F) to 50°C (122°F) at sea level and 45°C (113°F) at 3000 m (10,000 ft), front-to-back airflow

• 0°C (32°F) to 45°C (113°F) at sea level and 40°C (104°F) at 3000 m (10,000 ft), back-to-front airflow

For the 5120-24X-4Y model:

• 0°C (32°F) to 50°C (122°F) at sea level and at 3000 m (10,000 ft), front-to-back airflow

• 0°C (32°F) to 50°C (122°F) at sea level and 45°C (113°F) at 3000 m (10,000 ft), back-to-front airflow

For the 5120-24XT-4Y model:

• 0°C (32°F) to 50°C (122°F) up to 3000 m (10,000 ft), front-to-back and back-to-front airflow

Storage Temperature: -40°C to 70°C (-40°F to 158°F)

Operating Relative Humidity: 5% to 95% (non-condensing)


What are the interface specifications for the different EXTREME 5120-44X-4Y-2C-AC-R series models?

Each Extreme 5120 Series switch, including the EXTREME 5120-44X-4Y-2C-AC-R, includes a Micro-B USB serial console port, an RJ-45 serial console port, a 100/1000BASE-T out-of-band management port, and a USB Type A storage port. The specific interfaces for each switch are listed below:

5120-44X-4Y-2C (base) Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 empty fan slots, and 2 empty modular power supply unit slots.
5120-44X-4Y-2C-AC-F Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow.
5120-44X-4Y-2C-AC-R Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow.
5120-44X-4Y-2C-TAA (base) Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant.
5120-44X-4Y-2C-AC-F-TAA Stackable switch with 44 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 2 100Gb QSFP28 Universal/stack/uplink ports, 6 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant.
5120-24X-4Y (base) Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots.
5120-24X-4Y-AC-F Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow.
5120-24X-4Y-AC-R Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow.
5120-24X-4Y-TAA (base) Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant.
5120-24X-4Y-AC-F-TAA Stackable switch with 24 1Gb/10Gb SFP+ ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant.
5120-24XT-4Y (base) Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots.
5120-24XT-4Y-AC-F Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow.
5120-24XT-4Y-AC-R Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Back-to-front airflow.
5120-24XT-4Y-TAA (base) Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 empty fan slots, and 2 empty modular power supply unit slots. TAA compliant.
5120-24XT-4Y-AC-F-TAA Stackable switch with 24 1Gb/10GBase-T non-PoE ports, 4 10Gb/25Gb SFP28 ports, 4 fans, 1 modular AC power supply unit, and 1 empty modular power supply unit slot. Front-to-back airflow. TAA compliant.

What are the available power supply and fan options for the EXTREME 5120-44X-4Y-2C-AC-R?

Part Number Description
XN-ACPWR-550W-FB-A 550W AC power supply with front-to-back airflow for 5120 Series switches.
XN-ACPWR-550W-BF-A 550W AC power supply with back-to-front airflow for 5120 Series switches.
XN-FAN-005-F Fan module with front-to-back airflow for 5120 Series switches.
XN-FAN-005-R Fan module with back-to-front airflow for 5120 Series switches.

What rack-mount kits are available for the EXTREME 5120-44X-4Y-2C-AC-R?

Part Number Description
XN-2P-RMKIT-014 Two-post rack mount kit for 5120 Series switches for use with two- or four-post racks.

What are the power specifications for the EXTREME 5120-44X-4Y-2C-AC-R?

Model Specification
All models AC Input: 100-120/200-240 VAC, 50-60 Hz, 2.5/1.2 A Max. for each PSU

What are the important safety notices for the EXTREME 5120-44X-4Y-2C-AC-R?

Please observe the following safety notices when working with the EXTREME 5120-44X-4Y-2C-AC-R:

Electrical Hazard: Only qualified instructed or skilled personnel should perform installation, repair, or disassembly procedures.

Power Supplies: Extreme Networks power supplies do not have switches for turning the unit on and off. Before servicing, disconnect all power cords to remove power from the device. Make sure that these connections are easily accessible.

Installation Location: This equipment is designed for installation in restricted access locations and suitable for installation in Information Technology Rooms, not suitable for use in locations where children are likely to be present.

Circuit Breaker: A dedicated Listed circuit breaker rated at 15A is to be used for each power supply connection.

Mounting Stability: Before mounting the device, ensure that the rack can support it without compromising stability. Otherwise, personal injury or equipment damage may result.

ESD: Follow appropriate ESD procedures when unpacking and handling the switch. These include unpacking the switch in an ESD-safe environment and wearing appropriate ESD protective gear, such as ESD-safe footwear and ESD wrist straps where appropriate.

Indoor Use: This unit must be installed indoors. The unit, AC power adapter, and its cables are not designed for outdoor use.

Radiation Exposure: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Laser Safety: Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. Use only UL/CSA, IEC/EN60825-1/-2 recognized pluggable modules.

Shock Hazard: Disconnect all power inputs before servicing.

Battery: This product contains a battery used to maintain product information. If the battery should need replacement it must be replaced by Service Personnel. Risk of explosion if battery is replaced by an incorrect type. Dispose of expended battery in accordance with local disposal regulations.