What is included in the box with the ABUS FUMK80100?
The scope of delivery for the ABUS FUMK80100 includes:
• 1x Wireless Door-Contact (Sensor and Magnet)
• 1x Battery
• 3x Spacers
• 1x Safety Instruction Manual
• 1x Information Manual
What tools are required to install the ABUS FUMK80100?
For installation, you will require four Ø 3.0 mm (M3) screws and corresponding wall plugs.
Who should install the ABUS FUMK80100?
The ABUS FUMK80100 must be installed and maintained by a qualified service engineer.
What are the main components of the ABUS FUMK80100?
The main components of the ABUS FUMK80100 are:
1. Sensor
2. LED
3. Magnet
4. Tamper switch
5. Potentiometer
6. DIP Switch
7. Input external contact
8. Learning button
9. Battery-compartment
How do I pair the ABUS FUMK80100 with the Alarm Panel?
To learn the ABUS FUMK80100 device to the alarm panel, follow these steps:
1. Remove the backplate of the Sensor and the inner housing.
2. Insert the battery. The device will power up.
3. Start the Learning process in the Comfion App and follow the instructions. The LED will stop blinking to indicate that the learning process is complete.
What are the mounting guidelines for the ABUS FUMK80100?
Please follow these guidelines when mounting your ABUS FUMK80100:
• Mounting the device on or within 1 meter of metallic substances will impact the radio range.
• Use the enclosed spacers if necessary.
• Mount the Sensor on the door/window-frame and the magnet on the moving part of the door/window.
• The magnet can be mounted on the right or left side of the detector.
• Ensure that the magnet and sensor are aligned at the top edge and that the parallel distance between them is less than 20 mm.
What are the detection and restore distances for the ABUS FUMK80100?
The open/close detection distance for the ABUS FUMK80100 depends on the mounting surface and angle. The values, which apply for both right and left mounting of the magnet, are as follows:
| Surface | Status | Distance (mm) X+ | Distance (mm) X- | Distance (mm) Y | Distance (mm) Z |
|---|---|---|---|---|---|
| non-metallic | Detect | 52 | 60 | 12 | 20 |
| Restore | 42 | 40 | 16 | 27 | |
| Metallic | Detect | 42 | 35 | 20 | 25 |
| Restore | 35 | 30 | 26 | 33 |
What are the technical specifications of the ABUS FUMK80100?
| Specification | Details |
|---|---|
| Dimensions – Sensor / Magnet (W x H x D) | 24 x 90 x 26 mm / 9 x 44 x 16 mm |
| Weight Sensor and Magnet | 32 g (without battery) / 54 g (with battery) |
| Operating temperature | -10 °C to +40 °C |
| Environmental class | II (EN 50131-1 + A3:2020) |
| Humidity, max. | max. 85% RH (relative humidity) |
| Display | Status LED |
| Type of detection | Reed-switch, accelerometer |
| Operating frequency / modulation | 868.0 – 868.6 MHz / GFSK |
| HF transmission power / range | max. 25 mW (14 dBm) / 1000m, open space |
| Battery type & Battery life | 1 x AA (LR6) Alkaline Battery 1.5V, 4.5 years |
| Recommended Battery | Duracell Procell MN1500, or GP Super 15A, or Eveready Energizer E91 |
| Type of power supply | Type C (EN 50131-1+A3:2020) |
| Tamper monitoring | yes, (1 x Wall-Tamper) |
| Security level | Grade 2 (EN 50131-1 + A3:2020) |
| Standards for Intrusion and Hold-up Alarm devices | compliant with EN 50131-1 + A3:2020, EN 50131-2-6:2008, EN 50131-2-8:2016 and EN 50131-5-3:2017 at security level 2 if installed correctly together with the Comfion Wireless Alarm System FUAA80xxx. |
| EU-directives | RED: 2014/53/EU, RoHS: 2011/65/EU + 2015/863 + General Safety: 2001/95/EC |