What is the intended use of the ABUS FUBE50012?

You should read the notes and advice in the user guide carefully. If you do not follow these instructions, your guarantee claim becomes invalid. No liability can be accepted for resulting damages. No part of the product may be changed or modified in any way. The remote control is not waterproof. Please avoid direct contact with water.


What are the safety guidelines for the battery of the ABUS FUBE50012?

The device is supplied with direct current from a 3V lithium battery. To guarantee a long service life and avoid fire and injury, please note the following:

• Do not dispose of the battery in domestic waste.

• The battery must not be directly exposed to heat or sunlight, and must not be stored in a place with a very high temperature.

• The battery must not be burned.

• The battery must not come into contact with water.

• The battery must not be dismantled, pierced or otherwise damaged.

• The battery contacts must not be short-circuited.

• The battery must be kept away from small children.

• The battery cannot be recharged.


How should I dispose of the ABUS FUBE50012?

The product contains valuable raw materials. At the end of its service life, dispose of the product according to the applicable legal requirements. Within the EU, the product and its accessories must be collected and disposed of separately. Devices displaying the crossed-out wheeled bin symbol may not be disposed of as domestic waste. Please dispose of the products at the local collection point for electronic waste.


What are the features of the ABUS FUBE50012?

The wireless remote control is used for arming and disarming alarm systems. It indicates the current status of the alarm system. A switching output can also be armed as an option. The wireless remote control has a panic feature. This can also be used for controlling 868 MHz transceivers in the Secvest/Terxon product range.


What are the technical specifications of the ABUS FUBE50012?

Wireless frequency: 868.6625 MHz
Transmission power: max. 10 mW (amplifier output)
Range (outdoors): approx. 200 m
Range (indoors): Depending on ambient conditions
Power supply: Lithium battery type / CR 2450 Li-Mn 3V
Operating temperature: -10° C to +40° C
Humidity: max. 75% (non-condensing)
Dimension (WxHxD): 36.2 x 62 x 17 mm
Weight: 35 g
Security level: 2 (EN 50131-1:2006)
Environmental class: II (EN 50131-1:2006)
Standard: EN 50131-3

How do I insert or change the battery in my ABUS FUBE50012?

Before the wireless remote control can be used, the battery has to be inserted. When inserting the battery, all the LED pairs light up red and green one after another which show that all the LEDs are working properly. If the battery is empty, the red LEDs next to the asterisk (*) and question mark (?) buttons will light up.


How can I read the software version of my ABUS FUBE50012?

After inserting the battery, the software version of the remote control is then shown by the two LEDs at the top. The main version is shown by the flashing red LED and the sub version is shown by the flashing green LED.


How do I program (“learn in”) the ABUS FUBE50012?

Follow the steps described in the user guide for the compatible component. The “*” button can be used for “arming internally” or for switching an output.


How do I operate the ABUS FUBE50012?

Arming the alarm system: Press the button with the closed lock symbol. The green LED next to this button will light up to confirm.

Arming internally: Press the button with the asterisk (*) symbol. The green LED next to this button will light up to confirm.

Arming failure: If arming fails, the red LEDs next to the closed lock and asterisk buttons will light up.

Disarming: Press the button with the open lock symbol. The green LED next to this button will light up to confirm.

Disarming after alarm: Press the button with the open lock symbol. The red LEDs next to the closed lock and asterisk buttons will light up, and the green LED next to the open lock button will also light up.

Status query: Press the button with the question mark (?) symbol. The device will indicate the current status:

System is armed: The red LED next to the closed lock button lights up.

System is armed internally: The red LED next to the asterisk (*) button lights up.

System is disarmed: The green LED next to the open lock button lights up.

Trigger panic alarm: Press the closed lock and open lock buttons simultaneously. The red LEDs next to all three buttons (lock, asterisk, unlock) will light up.

Switching output: Press the asterisk (*) button to toggle the connected switching output.


Are there any special considerations for VdS conformal usage with the ABUS FUBE50012?

When arming the system, you are not allowed to be in the controlled area. When using alarm panels which are installed regarding VdS3438, this device is not allowed for arming or disarming the panel.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD ABUS FUBE50012 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.