What do the safety symbols mean in the documentation for the ABB POWERVALUE 11 LI UP 600VA?

The following symbols are used in the manual for the ABB POWERVALUE 11 LI UP 600VA:

Electrical Hazard Symbol (lightning bolt in a triangle): This symbol in conjunction with the signal word “DANGER” indicates an imminent electrical hazard. Failure to observe the related safety note may cause injury, death or equipment damage.

Warning Symbol (exclamation mark in a triangle): This symbol in conjunction with the signal word “WARNING” indicates a potentially dangerous situation. Failure to observe may cause injury, death or equipment damage.

Do Not Dispose Symbol (wheeled bin with a cross through it): This symbol indicates that you should not dispose of the item with ordinary trash.


What safety precautions must be taken regarding electric shock before disassembling the ABB POWERVALUE 11 LI UP 600VA?

RISK OF ELECTRIC SHOCK:

Before disassembling the ABB POWERVALUE 11 LI UP 600VA, make sure the UPS is completely switched off and internal capacitors have been discharged by waiting at least 5 minutes after shutting down the unit.


What precautions should be observed when disassembling an ABB POWERVALUE 11 LI UP 600VA that contains batteries?

The ABB POWERVALUE 11 LI UP 600VA may contain batteries. A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when disassembling a unit that contains batteries:

A) Remove watches, rings or other metal objects.

B) Use tools with insulated handles.

C) Wear rubber gloves and boots.

D) Do not lay tools or metal parts on top of batteries.

E) Disconnect the charging source prior to connecting or disconnecting of battery terminals.

F) Establish if the battery is inadvertently grounded. If inadvertently grounded, remove source from ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance (applicable to equipment and remote battery supplies not having grounded supply circuit. A battery can present a risk of electrical shock and high short circuit current.

Keep out of battery poles which contain dangerous DC-voltages causing fatal accidents.

Inappropriate manipulations of the batteries can cause lightning sparks.


Which products does the end-of-life treatment document apply to for the ABB POWERVALUE 11 LI UP 600VA series?

This document covers the environmental information for the following products:

Product Part number
UPS PowerValue 11LI Up 600VA 4NWP100170R0001
UPS PowerValue 11LI Up 800VA 4NWP100171R0001
UPS PowerValue 11LI Up 1000VA 4NWP100172R0001
UPS PowerValue 11LI Up 1500VA 4NWP100173R0001
UPS PowerValue 11LI Up 2000VA 4NWP100174R0001

What substances and components in the ABB POWERVALUE 11 LI UP 600VA require selective treatment for recycling?

The following table is intended to guide selective treatment and recycling, showing where which substances of concern are used and where they are located.

Substance(s)/Component(s) Where used (potential)
Batteries Used as VRLA block(s).
Printed circuit boards Used.
Plastic containing brominated flame retardants (BFRs) – plastic enclosure,
– PVC insulation of internal wiring,
– input/output receptacles,
– bobbin of 50Hz transformer.
Liquid crystal displays (> 100 cm²) Not used.
Spare electrolyte capacitors (height > 25 mm, diameter > 25 mm) Not used.
Polychlorinated biphenyls containing capacitors Not used.
Mercury containing components Not used.
Toner cartridges Not used.
Asbestos components which contain asbestos Not used.
Cathode ray tubes Not used.
CFC, HCFC, HFC, HC Not used.
Gas discharge lamps Not used.
External electric cables Not used.
Components containing refractory ceramic fibres Not used.
Components containing radioactive substances Not used.

What other materials and components are present in the ABB POWERVALUE 11 LI UP 600VA that are not indicated elsewhere?

High level component Substance(s)
Original packaging – Paper,
– Polyethylene foam or film
Fasteners – Steel, zinc plated
Cables with end terminals – Copper,
– Brass,
– PVC,
– Nylon,
– PBT

The following electrical components require further separation after removal from UPS. They might contain materials or components requiring selective disposal. Contact the manufacturer to get proper instructions:

– 50Hz Transformer;

– fan.


What should I be aware of regarding electrical energy storage before dismantling components of the ABB POWERVALUE 11 LI UP 600VA?

RISK OF ELECTRIC SHOCK:

– CAPACITORS AND OTHER UPS COMPONENTS MAY STORE NON-LETHAL ENERGY FOR LONG TIME: HANDLE EVERY CONDUCTIVE PART WITH CARE, AVOIDING SHORT CIRCUIT CAUSING SPARKING OR ARCING.

– BEFORE DISASSEMBLYING COMPONENTS REQUIRING FURTHER RECYCLING, CONTACT THE MANUFACTURER TO GET NECESSARY DISPOSAL INFORMATION;


What are the hazardous substances in the VRLA battery blocks of the ABB POWERVALUE 11 LI UP 600VA?

VRLA BATTERY BLOCKS CONTAINS HAZARDOUS SUBSTANCES AS:

– INORGANIC LEAD, LEAD COMPOUNDS (Pb – CAS 7439-92-1);

– SULFURIC ACID (CAS 7664-93-9 – CAUSES SEVERE BURNS).

THE CONCENTRATION MAY CHANGE, DEPENDING ON THE MANUFACTURER.

WARNING: CUTTING OR DAMAGING THE PLASTIC CASE, WILL EXPOSE ENVIROMENT TO FURTHER HAZARDOUS SUBSTANCES AS LEAD MONOXIDE (CAS 1317-36-8 -HARMFUL BY INHALATION AND IF SWALLOWED).


How do I remove the battery from my ABB POWERVALUE 11 LI UP 600VA?

Follow these steps to remove the battery for the ABB POWERVALUE 11 LI UP 600VA:

1. Loosen the screws that hold the bottom battery panel (A).

2. Remove the bottom battery panel (A).

3. Swipe out the battery (B).

4. Disconnect the battery wires (C).


What are the main internal components inside the ABB POWERVALUE 11 LI UP 600VA?

After removing all the screws on the base and opening the cover, the main internal components are:

– Fan

– Printed Circuit Board

– Receptacles

– Transformer

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD ABB POWERVALUE 11 LI UP 600VA (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.