What do the safety symbols on the ABB POWERVALUE 11 LI UP 1500VA mean?

The following symbols are used in the manual for the ABB POWERVALUE 11 LI UP 1500VA:

Electrical Hazard Symbol (Lightning bolt in a triangle) with “DANGER”: This indicates an imminent electrical hazard. Failure to observe the related safety note may cause injury, death, or equipment damage.

Exclamation point in a triangle with “WARNING”: This indicates a potentially dangerous situation. Failure to observe may cause injury, death, or equipment damage.

Crossed-out wheeled bin: This symbol means do not dispose of the equipment with ordinary trash.


What are the safety rules regarding electric shock when handling the ABB POWERVALUE 11 LI UP 1500VA?

To avoid the risk of electric shock when handling the ABB POWERVALUE 11 LI UP 1500VA, follow these safety rules:

Before disassembling the unit, make sure the UPS is completely switched off and internal capacitors have been discharged by waiting at least 5 minutes after shutting down the unit.

Capacitors and other UPS components may store non-lethal energy for a long time. Handle every conductive part with care, avoiding short circuits that can cause sparking or arcing.

Before disassembling components that require further recycling, contact the manufacturer to get necessary disposal information.


What precautions should be taken when disassembling an ABB POWERVALUE 11 LI UP 1500VA that contains batteries?

The unit contains batteries which can present a risk of electrical shock and high short circuit current. The following precautions should be observed when disassembling the ABB POWERVALUE 11 LI UP 1500VA:

A) Remove watches, rings, or other metal objects.

B) Use tools with insulated handles.

C) Wear rubber gloves and boots.

D) Do not lay tools or metal parts on top of batteries.

E) Disconnect the charging source prior to connecting or disconnecting battery terminals.

F) Establish if the battery is inadvertently grounded. If it is, remove the source from the ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance.

Keep out of battery poles which contain dangerous DC-voltages causing fatal accidents. Inappropriate manipulations of the batteries can cause lightning sparks.


What hazardous substances are contained within the VRLA battery blocks of the ABB POWERVALUE 11 LI UP 1500VA?

VRLA battery blocks in the ABB POWERVALUE 11 LI UP 1500VA contain the following hazardous substances:

– INORGANIC LEAD, LEAD COMPOUNDS (Pb – CAS 7439-92-1)

– SULFURIC ACID (CAS 7664-93-9 – CAUSES SEVERE BURNS).

The concentration may change depending on the manufacturer.

WARNING: Cutting or damaging the plastic case will expose the environment to further hazardous substances like LEAD MONOXIDE (CAS 1317-36-8), which is harmful by inhalation and if swallowed.


Which ABB PowerValue 11LI Up models are covered by these end-of-life instructions?

These instructions cover the environmental information for the following products:

Product Part number
UPS PowerValue 11LI Up 600VA 4NWP100170R0001
UPS PowerValue 11LI Up 800VA 4NWP100171R0001
UPS PowerValue 11LI Up 1000VA 4NWP100172R0001
UPS PowerValue 11LI Up 1500VA 4NWP100173R0001
UPS PowerValue 11LI Up 2000VA 4NWP100174R0001

What substances of concern require selective treatment for the ABB POWERVALUE 11 LI UP 1500VA?

Substance(s)/Component(s) Where used (potential)
Batteries Used as VRLA block(s).
Printed circuit boards Used.
Plastic containing brominated flame retardants (BFRs) – plastic enclosure,
– PVC insulation of internal wiring,
– input/output receptacles,
– bobbin of 50Hz transformer.
Liquid crystal displays (> 100 cm²) Not used.
Spare electrolyte capacitors (height > 25 mm, diameter > 25 mm) Not used.
Polychlorinated biphenyls containing capacitors Not used.
Mercury containing components Not used.
Toner cartridges Not used.
Asbestos components which contain asbestos Not used.
Cathode ray tubes Not used.
CFC, HCFC, HFC, HC Not used.
Gas discharge lamps Not used.
External electric cables Not used.
Components containing refractory ceramic fibres Not used.
Components containing radioactive substances Not used.

What are the other materials and components used in the ABB POWERVALUE 11 LI UP 1500VA?

High level component Substance(s)
Original packaging – Paper,
– Polyethylene foam or film
Fasteners – Steel, zinc plated
Cables with end terminals – Copper,
– Brass,
– PVC,
– Nylon,
– PBT

The following electrical components require further separation after removal from the UPS and may contain materials requiring selective disposal. Contact the manufacturer for proper instructions:

– 50Hz Transformer;

– fan.


How do I remove the battery from an ABB POWERVALUE 11 LI UP 600VA/800VA model?

1. Loosen the screws that hold the bottom battery panel (A).

2. Remove the bottom battery panel (A).

3. Swipe out the battery (B).

4. Disconnect the battery wires.


How do I remove the batteries from the ABB POWERVALUE 11 LI UP 1500VA?

Follow these steps to remove the batteries from the 1000VA, 1500VA, and 2000VA models:

1. Loosen the screws that hold the bottom battery panel (A).

2. Remove the bottom battery panel (A).

3. Swipe out the first battery (B2).

4. Remove the two supports (D1 and D2).

5. Swipe out the second battery (B1).

6. Disconnect the batteries wires (C).


How do I access the internal components of the ABB POWERVALUE 11 LI UP 1500VA?

To access the internal components like the Fan, Printed Circuit Board, Transformer, and Receptacles, remove all the screws on the base and open the cover.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD ABB POWERVALUE 11 LI UP 1500VA (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.