What do the safety symbols in the manual for the ABB POWERVALUE 11 LI UP 2000VA indicate?
The symbols used for the ABB POWERVALUE 11 LI UP 2000VA are explained as follows:
Electrical Hazard Symbol (Lightning Bolt in Triangle) with “DANGER”: This symbol indicates an imminent electrical hazard. Failure to observe the related safety note may cause injury, death, or equipment damage.
Exclamation Mark in Triangle with “WARNING”: This symbol indicates a potentially dangerous situation. Failure to observe may cause injury, death, or equipment damage.
Crossed-out Wheeled Bin Symbol: This symbol means do not dispose of the equipment with ordinary trash.
What are the critical safety precautions to take before disassembling the ABB POWERVALUE 11 LI UP 2000VA to avoid electric shock?
To avoid the risk of electric shock before disassembling the ABB POWERVALUE 11 LI UP 2000VA, you must make sure the UPS is completely switched off and internal capacitors have been discharged by waiting at least 5 minutes after shutting down the unit.
What precautions should be observed when disassembling an ABB POWERVALUE 11 LI UP 2000VA that contains batteries?
The ABB POWERVALUE 11 LI UP 2000VA may contain batteries, which can present a risk of electrical shock and high short circuit current. The following precautions should be observed when disassembling a unit that contains batteries:
A) Remove watches, rings or other metal objects.
B) Use tools with insulated handles.
C) Wear rubber gloves and boots.
D) Do not lay tools or metal parts on top of batteries.
E) Disconnect the charging source prior to connecting or disconnecting of battery terminals.
F) Establish if the battery is inadvertently grounded. If inadvertently grounded, remove source from ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance.
Keep out of battery poles which contain dangerous DC-voltages causing fatal accidents. Inappropriate manipulations of the batteries can cause lightning sparks.
Which specific products are covered by these end-of-life instructions?
These instructions cover the environmental information for the following ABB PowerValue 11 LI Up products:
| Product | Part number |
|---|---|
| UPS PowerValue 11LI Up 600VA | 4NWP100170R0001 |
| UPS PowerValue 11LI Up 800VA | 4NWP100171R0001 |
| UPS PowerValue 11LI Up 1000VA | 4NWP100172R0001 |
| UPS PowerValue 11LI Up 1500VA | 4NWP100173R0001 |
| UPS PowerValue 11LI Up 2000VA | 4NWP100174R0001 |
What substances or components of concern require selective treatment for the ABB POWERVALUE 11 LI UP 2000VA?
The following table guides the selective treatment and recycling for the ABB POWERVALUE 11 LI UP 2000VA.
| Substance(s)/Component(s) | Where used (potential) |
|---|---|
| Batteries | Used as VRLA block(s). |
| Printed circuit boards | Used. |
| Plastic containing brominated flame retardants (BFRs) | – plastic enclosure, – PVC insulation of internal wiring, – input/output receptacles, – bobbin of 50Hz transformer. |
| Liquid crystal displays (> 100 cm²) | Not used. |
| Spare electrolyte capacitors (height > 25 mm, diameter > 25 mm) | Not used. |
| Polychlorinated biphenyls containing capacitors | Not used. |
| Mercury containing components | Not used. |
| Toner cartridges | Not used. |
| Asbestos components which contain asbestos | Not used. |
| Cathode ray tubes | Not used. |
| CFC, HCFC, HFC, HC | Not used. |
| Gas discharge lamps | Not used. |
| External electric cables | Not used. |
| Components containing refractory ceramic fibres | Not used. |
| Components containing radioactive substances | Not used. |
What are the other materials and components found in the ABB POWERVALUE 11 LI UP 2000VA?
| High level component | Substance(s) |
|---|---|
| Original packaging | – Paper, – Polyethylene foam or film |
| Fasteners | – Steel, zinc plated |
| Cables with end terminals | – Copper, – Brass, – PVC, – Nylon, – PBT |
Which electrical components in the ABB POWERVALUE 11 LI UP 2000VA require further separation for proper disposal?
The following electrical components require further separation after removal from the ABB POWERVALUE 11 LI UP 2000VA. They might contain materials or components requiring selective disposal. Contact the manufacturer for proper instructions:
– 50Hz Transformer;
– fan.
What are the warnings regarding electric shock when dismantling the ABB POWERVALUE 11 LI UP 2000VA?
RISK OF ELECTRIC SHOCK:
– CAPACITORS AND OTHER UPS COMPONENTS MAY STORE NON-LETHAL ENERGY FOR LONG TIME: HANDLE EVERY CONDUCTIVE PART WITH CARE, AVOIDING SHORT CIRCUIT CAUSING SPARKING OR ARCING.
– BEFORE DISASSEMBLYING COMPONENTS REQUIRING FURTHER RECYCLING, CONTACT THE MANUFACTURER TO GET NECESSARY DISPOSAL INFORMATION;
What hazardous substances are in the VRLA battery blocks of the ABB POWERVALUE 11 LI UP 2000VA?
VRLA BATTERY BLOCKS CONTAINS HAZARDOUS SUBSTANCES AS:
– INORGANIC LEAD, LEAD COMPOUNDS (Pb – CAS 7439-92-1);
– SULFURIC ACID (CAS 7664-93-9 – CAUSES SEVERE BURNS).
THE CONCENTRATION MAY CHANGE, DEPENDING ON THE MANUFACTURER.
WARNING: CUTTING OR DAMAGING THE PLASTIC CASE, WILL EXPOSE ENVIROMENT TO FURTHER HAZARDOUS SUBSTANCES AS LEAD MONOXIDE (CAS 1317-36-8 – HARMFUL BY INHALATION AND IF SWALLOWED).
How do I remove the battery from my ABB POWERVALUE 11 LI UP 2000VA?
To remove the battery from an ABB POWERVALUE 11 LI UP 1000VA, 1500VA, or 2000VA model, follow these steps:
1. Loosen the screws that hold the bottom battery panel (A).
2. Remove the bottom battery panel (A).
3. Swipe out the first battery (B2).
4. Remove the two supports (D1 and D2).
5. Swipe out the second battery (B1).
6. Disconnect the batteries wires (C).
How do I open the main cover of the ABB POWERVALUE 11 LI UP 2000VA and what are the main internal components?
To open the cover of the ABB POWERVALUE 11 LI UP 2000VA, remove all the screws on the base.
The main internal components visible after opening the cover are:
– Fan
– Receptacles
– Printed Circuit Board
– Transformer