FREE ENGLISH SHURE PA821A (01) PDF USER GUIDE

FREE ENGLISH SHURE PA821A (01) PDF USER MANUAL

FREE ENGLISH SHURE PA821A (01) PDF OWNER GUIDE

FREE ENGLISH SHURE PA821A (01) PDF OWNER MANUAL

FREE ENGLISH SHURE PA821A (01) PDF REFERENCE GUIDE

FREE ENGLISH SHURE PA821A (01) PDF INSTRUCTION GUIDE

FREE ENGLISH SHURE PA821A (01) PDF REFERENCE MANUAL

FREE ENGLISH SHURE PA821A (01) PDF INSTRUCTION MANUAL

FREE ENGLISH SHURE PA821A (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD SHURE PA821A (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the important safety instructions for this product?

1. READ these instructions.

2. KEEP these instructions.

3. HEED all warnings.

4. FOLLOW all instructions.

5. DO NOT use this apparatus near water.

6. CLEAN ONLY with dry cloth.

7. DO NOT block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9. DO NOT defeat the safety purpose of the polarized or groundingtype plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10. PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11. ONLY USE attachments/accessories specified by the manufacturer.

12. USE only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. UNPLUG this apparatus during lightning storms or when unused for long periods of time.

14. REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with liquids, such as vases, on the apparatus.

16. The MAINS plug or an appliance coupler shall remain readily operable.

17. The airborne noise of the Apparatus does not exceed 70dB (A).

18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection.

19. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

20. Do not attempt to modify this product. Doing so could result in personal injury and/or product failure.

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.


What are the benefits of using the PA821A Antenna Combiner?

• Reduction of intermodulation artifacts for cleaner RF environment and more channels on air

• Simplified antenna placement


How do I power the PA821A Antenna Combiner?

• Turn power off before installing.

• Use the supplied power cable to connect the unit to an AC power source.

• The power LED illuminates when powered on.

• Power the unit off when not in use or before disconnecting the unit from the AC power source.


How do I configure the antennas with the PA821A?

• Attach an antenna to the MAIN OUT of the combiner. For wideband applications, use the PA805SWB directional antenna.

• Use the supplied BNC-BNC cables to connect the ANTENNA INPUTS of the antenna combiner to the antenna outputs of each transmitter (up to eight PSM wireless transmitters).


How do I use the Expansion Port on the PA821A?

The expansion port on the front panel may be used to combine the main output of the PA821 with the antenna output from another PSM transmitter or combiner.

1. Use the supplied one-foot jumper BNC-BNC cable to connect the MAIN Output to the A IN of the expansion port.

2. Connect the antenna output from a PSM transmitter or another PA421/PA821 to the B IN of the expansion port.

3. Attach the antenna to the A+B OUT of the expansion port.


What are the general specifications of the PA821A?

Dimensions 43 mm x 401 mm x 365 (1.7 in. x 15.8 in. x 14.4 in.), H x W x D
Weight 4.8 kg (10.5 lbs)
Operating Temperature Range -18°C (0°F) to 63°C (145°F)
Power Requirements 100 to 240 V AC, 50-60 Hz
Current Drain 1.5 A (referenced at 100 V AC) (150VA)
Power Consumption 70 W max.

What are the RF Input specifications for the PA821A?

Connector Type BNC (8)
Configuration Active
Impedance 50 Ω
RF Frequency Range 470-952 MHz
Absolute maximum RF input 24 dBm
RF gain 0 / -5 dB
LED Indicator Minimum Detection threshold 5.5 dBm

What are the Distribution Output specifications for the PA821A?

Connector Type BNC
Configuration Active
Impedance 50 Ω
Output Intercept Point (OIP3) >30 dBm, typical

What are the Expansion Port specifications for the PA821A?

Connector Type BNC
Configuration Passive
Impedance 50 Ω
Insertion Loss <4 dB

What accessories are furnished with the PA821A?

Cable, BNC (11 in.)95N2035
(8) 2 ft. Coaxial Cable (RG58C/U)UA802
120 VAC Power Line Cord*95B8389
230 VAC Power Line Cord*95C8247
240 VAC Power Line Cord (U.K.)*95A8713
VAC Power Line Cord (Argentina)*95A14335
VAC Power Line Cord (Brazil)*95A14336
*Model Dependent

What optional accessories are available for the PA821A?

Wideband Omnidirectional Antenna (470-952 MHz)PA805SWB
10 ft. Coaxial Cable (RG-8X/U)PA725
25 ft. Coaxial Cable (RG-8X/U)UA825
50 ft. Coaxial Cable (RG-8X/U)UA850

What certifications does the PA821A meet?

Meets essential requirements of the following European Directives:

• R&TTE Directive 99/5/EC

• WEEE Directive 2002/96/EC, as amended by 2008/34/EC

• RoHS Directive 2002/95/EC, as amended by 2008/35/EC

Note: Please follow your regional recycling scheme for electronic waste.

Meets requirements of the following standards: EN 301 489 Parts 1 and 9, EN60065.

Certified under FCC Part 74.

Conforms to electrical safety requirements based on IEC 60065.

Certified by IC in Canada under RSS-123 and RSS-102.

FCC ID: DD4PA821A. IC: 616A-PA821A.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation of this device is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Note: EMC conformance testing is based on the use of supplied and recommended cable types. The use of other cable types may degrade EMC performance.


Is licensing required to operate the PA821A?

Licensing: A ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements. Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment. Licensing of Shure wireless microphone equipment is the user’s responsibility, and licensability depends on the user’s classification and application, and on the selected frequency. Shure strongly urges the user to contact the appropriate telecommunications authority concerning proper licensing, and before choosing and ordering frequencies.