What are the critical safety precautions to follow when installing or operating the SCHNEIDER ELECTRIC TP-1011-116?
To avoid the hazard of electric shock, explosion, or arc flash when using the SCHNEIDER ELECTRIC TP-1011-116, you must adhere to the following safety precautions:
• Only qualified personnel should install this equipment.
• Disconnect all power supplying this equipment before working on it.
• Always use a properly rated voltage sensing device to confirm that power is off.
• Replace all devices, doors, and covers before turning on power to this equipment.
• The use of this equipment in a manner not specified by the manufacturer may impair the protection provided by the equipment.
Failure to follow these instructions will result in death or serious injury.
What do the safety signals mean on the SCHNEIDER ELECTRIC TP-1011-116?
The safety signals on the SCHNEIDER ELECTRIC TP-1011-116 indicate different levels of potential hazards:
DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
What items are included in the package for the SCHNEIDER ELECTRIC TP-1011-116?
The SCHNEIDER ELECTRIC TP-1011-116 package contains the following items:
• Display
• Mounting Clamp
• Bezel
• DC Power Plug
• Documentation
What are the components of the front panel of the SCHNEIDER ELECTRIC TP-1011-116?
The front panel of the SCHNEIDER ELECTRIC TP-1011-116 consists of two main components:
1. Status LED: This three-color LED (Green/Orange/Red) indicates the operational status of the display.
2. Display Area: The screen where all graphics are displayed.
What are the ports and connectors on the rear panel of the SCHNEIDER ELECTRIC TP-1011-116?
The rear panel of the SCHNEIDER ELECTRIC TP-1011-116 features the following ports and connectors:
1. DC Power Supply Connector: For connecting the power source.
2. COM1 / COM3 Port: A DB9 serial port for RS-232 and RS-485 communication.
3. COM2 Port: A DB9 serial port for RS-422 and RS-485 communication.
4. Ethernet Port: An RJ45 port for network connectivity.
5. USB Type-A Host Port: For connecting USB peripherals like a memory stick, mouse, or keyboard.
6. USB mini-B Device Port: For connecting to a PC to download or upload projects.
What are the physical dimensions of the SCHNEIDER ELECTRIC TP-1011-116?
The physical dimensions of the SCHNEIDER ELECTRIC TP-1011-116 are as follows:
| Dimension | Millimeters (mm) | Inches (in.) |
|---|---|---|
| Width (W) | 271.0 | 10.67 |
| Height (H) | 213.0 | 8.39 |
| Depth (D) | 37.7 | 1.48 |
What are the required panel cutout dimensions for installing the SCHNEIDER ELECTRIC TP-1011-116?
To install the SCHNEIDER ELECTRIC TP-1011-116, the panel cutout must match the following dimensions:
| Dimension | Millimeters (mm) | Inches (in.) |
|---|---|---|
| Cutout Width (X) | 259.0 (+1/-0) | 10.20 (+0.04/-0) |
| Cutout Height (Y) | 201.0 (+1/-0) | 7.91 (+0.04/-0) |
The recommended installation panel thickness should be between 1.5 and 6 mm (0.06 and 0.24 in.).
How do I properly install the SCHNEIDER ELECTRIC TP-1011-116 into a panel?
Follow these steps to install the SCHNEIDER ELECTRIC TP-1011-116:
1. Check the panel cutout dimensions to ensure they match the unit’s specifications.
2. Verify that the installation panel thickness is between 1.5 to 6 mm (0.06 to 0.24 in.).
3. Insert the SCHNEIDER ELECTRIC TP-1011-116 into the panel cutout.
4. Place the mounting clamps into the designated slots on the unit’s housing.
5. Tighten the clamp screws evenly until the bezel of the unit fits snugly against the panel. The recommended torque for the screws is 0.5 N-m (4.4 lbf-in).
What are the guidelines for wiring the DC power supply to the SCHNEIDER ELECTRIC TP-1011-116?
When wiring the DC power supply for the SCHNEIDER ELECTRIC TP-1011-116, please follow these guidelines:
• Use a Class 2 or SELV (Safety Extra Low Voltage) DC power source.
• Check that the power supply voltage is within the specified range for the display.
• Use the recommended wire gauge: AWG 22 to 14.
• To reduce the risk of interference, separate the DC power cable from high-voltage power cables or any cables that could induce electrical noise.
How do I properly ground the SCHNEIDER ELECTRIC TP-1011-116?
To ensure proper operation and noise protection for your SCHNEIDER ELECTRIC TP-1011-116, grounding is essential. Connect the FG (Frame Ground) terminal on the power connector to ground. For optimal performance, the grounding resistance must be 100 ohms or less.
What are the power connector pin assignments for the SCHNEIDER ELECTRIC TP-1011-116?
The 3-pin power connector on the SCHNEIDER ELECTRIC TP-1011-116 has the following pin assignments:
| Pin | Signal | Description |
|---|---|---|
| 1 | +24 Vdc | 24 Vdc power supply input |
| 2 | 0 V | 0 Vdc power supply ground |
| 3 | FG | Frame Ground |
What are the COM1/COM3 serial port pin assignments for the SCHNEIDER ELECTRIC TP-1011-116?
The COM1/COM3 port on the SCHNEIDER ELECTRIC TP-1011-116 is a 9-pin D-Sub male connector supporting RS-232 and RS-485. The pin assignments are as follows:
| Pin Number | RS-232 Signal | RS-485 Signal |
|---|---|---|
| 1 | – | DATA- |
| 2 | RXD | – |
| 3 | TXD | – |
| 4 | – | – |
| 5 | GND | GND |
| 6 | – | DATA+ |
| 7 | RTS | – |
| 8 | CTS | – |
| 9 | – | – |
What are the COM2 serial port pin assignments for the SCHNEIDER ELECTRIC TP-1011-116?
The COM2 port on the SCHNEIDER ELECTRIC TP-1011-116 is a 9-pin D-Sub male connector supporting RS-422 and RS-485. The pin assignments are as follows:
| Pin Number | RS-422 Signal | RS-485 Signal |
|---|---|---|
| 1 | RXD- | DATA- |
| 2 | RXD+ | – |
| 3 | TXD- | – |
| 4 | TXD+ | – |
| 5 | GND | GND |
| 6 | – | DATA+ |
| 7 | – | – |
| 8 | – | – |
| 9 | – | – |
What are the Ethernet (LAN) port pin assignments for the SCHNEIDER ELECTRIC TP-1011-116?
The Ethernet LAN port on the SCHNEIDER ELECTRIC TP-1011-116 is a 10/100 Base-T port with the following pin assignments:
| Pin Number | Signal |
|---|---|
| 1 | TX+ |
| 2 | TX- |
| 3 | RX+ |
| 6 | RX- |
What are the functions of the USB ports on the SCHNEIDER ELECTRIC TP-1011-116?
The SCHNEIDER ELECTRIC TP-1011-116 is equipped with two types of USB ports:
• USB Type-A (Host): This port is compatible with USB 2.0 and is used for connecting peripherals such as a USB memory stick, a mouse, or a keyboard.
• USB mini-B (Device): This port is also compatible with USB 2.0 and is used for connecting the display to a personal computer (PC) to download or upload projects.
What are the general and performance specifications of the SCHNEIDER ELECTRIC TP-1011-116?
| Power Supply | 24 Vdc |
| Input Voltage Range | 10.8 to 28.8 Vdc |
| Power Consumption | 12.5 W |
| Enclosure Material | Plastic |
| Dimensions (W x H x D) | 271.0 x 213.0 x 37.7 mm (10.67 x 8.39 x 1.48 in.) |
| Weight | 1.0 kg (2.2 lbs) |
| Processor | ARM Cortex-A8 (600 MHz) |
| Display Type | TFT Color LCD |
| Display Size | 10.1 in. |
| Display Colors | 65,536 colors |
| Resolution | 1024 x 600 pixels |
| Backlight | LED |
| Backlight Lifetime | 20,000 hrs |
| Touch Screen Type | 4-wire resistive |
| Flash Memory (eMMC) | 128 MB |
| RAM | 128 MB |
What are the I/O and interface specifications for the SCHNEIDER ELECTRIC TP-1011-116?
| SD Card | N/A |
| USB Host | USB 2.0 x 1 |
| USB Device | USB Mini-B x 1 |
| Ethernet | 10/100 Base-T x 1 |
| COM1 | RS-232 / RS-485 |
| COM2 | RS-422 / RS-485 |
| COM3 | RS-485 |
| Serial Port | COM1: RS-232 / RS-485 COM2: RS-422 / RS-485 COM3: RS-485 |
| Ethernet Port | 10/100 Base-T |
| USB | 1x USB Host (Type A), 1x USB Client (Mini-B) |
What are the environmental specifications for operating the SCHNEIDER ELECTRIC TP-1011-116?
| Degree of Protection (Front Panel) | Type 4X (indoor use only), IP66F |
| Degree of Protection (Rear Panel) | IP20 |
| Operating Temperature | 0°C to 50°C (32°F to 122°F) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
| Operating Humidity | 10% to 90% RH (non-condensing) |
| Vibration Resistance | 10 to 25 Hz (X, Y, Z direction, 2G, 30 minutes) |
| Agency Approvals | CE, cULus |
How should I perform maintenance and cleaning on the SCHNEIDER ELECTRIC TP-1011-116?
To clean and maintain your SCHNEIDER ELECTRIC TP-1011-116, follow these procedures:
• Disconnect the power from the unit before cleaning.
• Use a soft cloth dampened with a neutral detergent to clean the display.
• Do not spray liquids directly onto the display surface.
• Do not use organic solvents such as benzene, alcohol, or paint thinner, as these can deform or discolor the enclosure.
How do I troubleshoot common issues with the SCHNEIDER ELECTRIC TP-1011-116?
If you encounter issues with your SCHNEIDER ELECTRIC TP-1011-116, refer to the following troubleshooting table:
| Problem | Possible Cause | Corrective Action |
|---|---|---|
| Display does not turn on. | Power connector is loose or not connected. | Check that the power connector is firmly attached. |
| Power supply voltage is outside the rated range. | Check the power supply voltage. | |
| Communication error. | Communication parameters are not set correctly. | Verify the communication parameters on both the display and the connected device. |
| Communication cable is not connected correctly or is broken. | Check the wiring of the communication cable. | |
| PLC station number setting is not correct. | Verify that the PLC station number is set correctly. | |
| Display is not clear or is too dark. | Backlight is burned out or the display is broken. | Contact your local distributor for service. |
| Contrast and brightness settings are not adjusted correctly. | Adjust the contrast and brightness settings in the system settings screen. | |
| Touch screen is not responding or the touch position is incorrect. | Touch screen is not calibrated. | Calibrate the touch screen from the system settings screen. |
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD SCHNEIDER ELECTRIC TP-1011-116 (01) PDF DOCUMENT