SCHNEIDER ELECTRIC APC SMV1500A (01) Image

FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF DOCUMENT.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF USER GUIDE.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF USER MANUAL.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF OWNER GUIDE.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF OWNER MANUAL.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF REFERENCE GUIDE.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF REFERENCE MANUAL.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV1500A (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD SCHNEIDER ELECTRIC APC SMV1500A (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What do the important safety messages on the SCHNEIDER ELECTRIC APC SMV1500A mean?

Read all instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this document or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.

The addition of the electrical hazard symbol to either a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.

The safety alert symbol is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

DANGER: DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING: WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION: CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: NOTICE is used to address practices not related to physical injury.


What are the product handling guidelines for the SCHNEIDER ELECTRIC APC SMV1500A?

Follow these guidelines based on the weight of the equipment:

<18 kg (<40 lb): Can be handled by one person.

18-32 kg (40-70 lb): Requires two people to handle.

32-55 kg (70-120 lb): Requires three people to handle.

>55 kg (>120 lb): Requires mechanical assistance (e.g., a lift).


What are the general safety instructions for the SCHNEIDER ELECTRIC APC SMV1500A?

Adhere to all national and local electrical codes.

This UPS is intended for indoor use only. To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive contaminants.

Mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.

UPS must be connected to an earthed mains socket outlet.

Connect the power cable directly to a wall outlet. Do not use surge protectors or extension cords.

CAUTION: This UPS is designed to satisfy all of requirement of PCs only.

CAUTION: Risk of electric shock, do not remove the chassis cover. Servicing should be performed by Qualified Engineer.


What are the battery safety precautions for the SCHNEIDER ELECTRIC APC SMV1500A?

CAUTION: HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE

Failure to follow these instructions can result in injury.

• Replace the battery at least every 5 years.

• Replace the battery immediately when the UPS indicates battery replacement is necessary.

• Replace battery at the end of its service life.

• Replace batteries with the same number and type of batteries as originally installed in the equipment.

• Replace the battery immediately when the UPS indicates a battery over-temperature condition, or UPS internal over-temperature, or when there is evidence of electrolyte leakage. Power off the UPS, unplug it from the AC input, and disconnect the batteries. Do not operate the UPS until the batteries have been replaced.

General Battery Precautions:

• Servicing of user replaceable batteries should be performed or supervised by personnel knowledgeable about batteries and required precautions. In this case batteries are not user replaceable.

• When replacing battery the UPS must be OFF, and its AC inlet unplugged.

• CAUTION: Do not dispose of batteries in a fire. The batteries may explode.

• CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.

• Do not open or mutilate batteries. They contain an electrolyte that is toxic and harmful to the skin and eyes.

• CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries.

a. Remove watches, rings or other metal objects.

b. Use tools with insulated handles.

c. Wear rubber gloves and boots.

d. Do not lay tools or metal parts on top of batteries.

e. Disconnect the charging source prior to connecting or disconnecting battery terminals.

f. Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance.

• CAUTION: The UPS contains internal batteries and may present a shock hazard even when disconnected from AC power.

• CAUTION: Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may exist between battery terminals and ground. Test before touching.


What is the Radio Frequency Warning for the SCHNEIDER ELECTRIC APC SMV1500A?

This is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures.


What are the product features of the SCHNEIDER ELECTRIC APC SMV1500A?

A. ON/OFF button

B. RS-232

C. USB port

D. Fan/ventilation hole

E. Battery connector

F. AC Inlet

G. Fuse

H. Battery backup outlets with surge protection

I. Output breaker

J. Intelligent Slot

K. Dry contact

L. EPO


How do I interpret the front panel LCD display on the SCHNEIDER ELECTRIC APC SMV1500A?

Item Number Status Description
1 On Line mode
2 Battery mode
3 Automatic Voltage Regulation
4 Battery capacity
5 Load capacity
6 UPS status
7 Power ON/OFF button

How do I install and power on the SCHNEIDER ELECTRIC APC SMV1500A?

NOTICE: Before installing the UPS, ensure the input breaker on the UPS upstream is Type C rated at 16A.

1. Installation Location:

• The UPS MUST be installed indoors in a controlled environment free of excessive dust, corrosive air, or conductive dust.

• Do NOT install outdoors.

• Keep out of direct sunlight, water, and heat sources.

• Place the unit on a stable floor.

2. Connect the battery:

• Connect the battery by pulling the battery handle up, and then pushing it into the unit. The battery connector is located on the rear panel.

• Connect prior to operation.

• Disconnect prior to transportation. Turn OFF the UPS and remove the input power cable before disconnecting the battery connector.

3. Connect equipment to the UPS:

• Avoid using extension cords.

• Do NOT connect printers, heaters, or copiers to the UPS.

• During a power outage or other AC problems, the Battery Backup outlets receive power for a limited time from the Easy UPS.

4. Plug in the Easy UPS:

• Plug the Easy UPS power cord directly into a wall outlet, not into a surge protector or power strip.

5. Turn on the unit:

• Press the ON/OFF button to turn on the unit.

• The Easy UPS should charge the battery for at least 8 hours to ensure sufficient runtime.

• Press the ON/OFF button for 1-3 seconds. The buzzer sound confirms that the Easy UPS is on and providing power to outlets.

6. Cold start the UPS (optional):

• Use the cold start feature to supply power to connected equipment from the UPS batteries when the UPS is off and there is no utility power.

7. Connect and install management software:

• Easy UPS is provided with management software for unattended operating system shutdown, UPS monitoring, and UPS settings.


How does the dry contact interface on the SCHNEIDER ELECTRIC APC SMV1500A work?

When the UPS is operating in one of the conditions below, the dry contact interface will be activated.

• When the UPS detects a battery failure, PIN1-2 of a dry contact will be activated.

• When the UPS is operating in AC mode, PIN1-3 of a dry contact will be activated.

When UPS is operating in… Activate
1. AC mode PIN1-3
2. Backup mode N/A
3. Standby mode N/A
4. AC mode and Battery weak PIN1-2 & PIN1-3
5. Standby mode and Battery weak PIN1-2

What are the specifications of the SCHNEIDER ELECTRIC APC SMV1500A and related models?

Model SMV750A SMV1000A SMV1500A SMV2000CA SMV3000CA
Input Voltage 120VAC
Voltage range 83-145Vac±5Vac
Connection NEMA5-15P NEMA5-20P NEMA5-30P
Frequency Range 45-65 Hz (auto sensing) ±1Hz
Output UPS Capacity (total) 750VA
525W
1000VA
700W
1500VA
1050W
2000VA
1400W
3000VA
2100W
Rated Voltage 120VAC
Transfer time Typical 2-6 ms, 12ms max.
Waveform Pure Sine Wave
Battery Type (maintenance-free) 12V/7Ah x 2 lead acid 12V/7Ah x 2 lead acid 12V/10Ah x 2 lead acid 12V/7Ah x 4 lead acid 12V/9Ah x 4 lead acid
Charging time 4-6 hours recover to 90% capacity
Physical Dimension (DxWxH, mm) 410 x 160 x 220 455 x 180 x 240
Net Weight (kg) 15 18 20 28 31.5
Packaging Dimension (DxWxH, mm) 508 x 272 x 339 604 x 319 x 414
Gross Weight (kg) 18 21 23 32 35.5
Environment Operating temperature & Humidity 0-95% RH @ 0-40°C (non-condensing)
Noise level Less than 45 dB
Enclosure type IP20

What do the audible indicators and status icons mean on the SCHNEIDER ELECTRIC APC SMV1500A?

If the Easy UPS… Possible cause…
Beeps every 2 seconds. Easy UPS is running on battery. You should consider saving any work in progress.
Continuous Beeping. Low battery condition and battery run-time is very low. Promptly save any work in progress, exit all open applications, and shut down the operating system.
Continuous tone with Load Capacity icon illuminated. Battery Backup outputs are overloaded.
Continuous tone with ‘Err’ illuminated.
a. Press ON/OFF button for 1-3 seconds to mute the alarm.
b. Continuous tone will persist until battery LOW. (<11Vdc each BATT)

Err 01: Fan fault detected

Err 02: Inverter short

Err 03: Inverter over voltage

Err 04: Emergency power off, EPO

Beeps every 4 seconds with Battery icon illuminated. The battery is near the end of useful life or damaged.

What should I do if my SCHNEIDER ELECTRIC APC SMV1500A will not turn on?

If the Easy UPS has not been turned on, press the ON/OFF button.

If the Easy UPS is not connected to AC power, there is no AC power available at the wall outlet, or the AC power is experiencing a brownout or over voltage condition: Make sure the power cord is securely connected to the wall outlet, and that there is AC power available at the wall outlet. Where applicable, check that the wall outlet is switched on or the input fuse works properly.

If the battery is disconnected, make sure the battery connector is properly connected.


Why does my connected equipment lose power with the SCHNEIDER ELECTRIC APC SMV1500A?

An Easy UPS overload condition may have occurred. Remove all nonessential equipment connected to the outlets. One at a time, reconnect equipment to the Easy UPS.

The Easy UPS battery may be completely discharged. Connect the Easy UPS to AC power and recharge for 10 hours.

If these steps do not solve the issue, the Easy UPS may require service. Contact Schneider Electric Technical Support.


Why is my SCHNEIDER ELECTRIC APC SMV1500A operating on battery power while connected to AC power?

The plug may have partially pulled out of the wall outlet, the wall outlet may no longer be receiving AC power, or the fuse may have been blown. Ensure that the plug is fully inserted into the wall outlet. Ensure that the wall outlet is receiving AC power by checking it with another device. Or replace the fuse.


What do the ‘Err’ messages on the SCHNEIDER ELECTRIC APC SMV1500A display mean and how do I resolve them?

Err 01: Fan fault detected

Turn the Easy UPS off. Clean dust or foreign materials clogging the cooling fan and turn the Easy UPS on. If the error message persists, contact Schneider Electric Technical Support.

Err 02: Inverter short detected

Turn the Easy UPS off. Disconnect non-essential equipment from the outlets and turn the Easy UPS on. If the error message persists, contact Schneider Electric Technical Support.

Err 03: Inverter over voltage detected

Contact Schneider Electric Technical Support.

Err 04: Emergency power off, EPO

Make sure the EPO connector was removed. If the error message persists, contact Schneider Electric Technical Support.


Why is my SCHNEIDER ELECTRIC APC SMV1500A beeping every 4 seconds?

This may indicate the battery is disconnected. Make sure the battery connector in the rear panel is connected.

It can also mean the battery is near the end of its useful life or is damaged. Contact Schneider Electric Technical Support if the Easy UPS remains beeping with the battery connector securely connected.


Why does my SCHNEIDER ELECTRIC APC SMV1500A have an inadequate battery runtime?

The battery may not be fully charged. Leave the Easy UPS connected to AC power for 10 hours while the battery charges to full capacity.

The battery may be near the end of its useful life and should be replaced. As a battery ages, the runtime capability decreases.


What steps should I take if my SCHNEIDER ELECTRIC APC SMV1500A requires service?

If the unit requires service, do not return it to the dealer. Follow these steps:

1. Review the Troubleshooting section of the manual to eliminate common problems.

2. If the problem persists, contact Schneider Electric IT (SEIT) Customer Support. Note the model number, serial number, and the date of purchase. A technician will attempt to solve the problem. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#).

3. Pack the unit in the original packaging whenever possible to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty.

4. Always DISCONNECT THE UPS BATTERIES before shipping. The United States Department of Transportation (DOT), and the International Air Transport Association (IATA) regulations require that UPS batteries be disconnected before shipping. The internal batteries may remain in the UPS.

5. Write the RMA# provided by Customer Support on the outside of the package.

6. Return the unit by insured, pre-paid carrier to the address provided by Customer Support.