FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF DOCUMENT.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF USER GUIDE.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF USER MANUAL.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF OWNER GUIDE.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF OWNER MANUAL.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF REFERENCE GUIDE.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF REFERENCE MANUAL.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH SCHNEIDER ELECTRIC APC SMV750A (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD SCHNEIDER ELECTRIC APC SMV750A (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What do the safety messages on the SCHNEIDER ELECTRIC APC SMV750A mean?
The special messages in the manual and on the equipment warn of potential hazards or call attention to information that clarifies or simplifies a procedure. They are defined as follows:
DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Is used to address practices not related to physical injury.
The addition of a lightning bolt symbol to a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.
The exclamation point symbol is a safety alert symbol used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
What are the product handling guidelines for the SCHNEIDER ELECTRIC APC SMV750A based on its weight?
Please follow these guidelines for handling the unit based on its weight:
<18 kg (<40 lb): Can be handled by one person.
18-32 kg (40-70 lb): Requires two people to handle.
32-55 kg (70-120 lb): Requires three people to handle.
>55 kg (>120 lb): Requires a lifting aid.
What are the general safety guidelines for the SCHNEIDER ELECTRIC APC SMV750A?
Adhere to all national and local electrical codes.
This UPS is intended for indoor use only. To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive contaminants.
Mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.
UPS must be connected to an earthed mains socket outlet.
Connect the power cable directly to a wall outlet. Do not use surge protectors or extension cords.
CAUTION: This UPS is designed to satisfy all of requirement of PCs only.
CAUTION: Risk of electric shock, do not remove the chassis cover. Servicing should be performed by a Qualified Engineer.
What precautions should be taken regarding hydrogen sulphide gas and excessive smoke with the SCHNEIDER ELECTRIC APC SMV750A?
To avoid injury from hydrogen sulphide gas and excessive smoke, follow these instructions:
Replace the battery at least every 5 years.
Replace the battery immediately when the UPS indicates battery replacement is necessary.
Replace battery at the end of its service life.
Replace batteries with the same number and type of batteries as originally installed in the equipment.
Replace the battery immediately when the UPS indicates a battery over-temperature condition, or UPS internal over-temperature, or when there is evidence of electrolyte leakage. Power off the UPS, unplug it from the AC input, and disconnect the batteries. Do not operate the UPS until the batteries have been replaced.
What safety precautions are necessary when working with the batteries in the SCHNEIDER ELECTRIC APC SMV750A?
Servicing of user replaceable batteries should be performed or supervised by personnel knowledgeable about batteries and required precautions. In this case batteries are not user replaceable.
When replacing battery the UPS must be OFF, and its AC inlet unplugged.
CAUTION: Do not dispose of batteries in a fire. The batteries may explode.
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
Do not open or mutilate batteries. They contain an electrolyte that is toxic and harmful to the skin and eyes.
CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
a. Remove watches, rings or other metal objects.
b. Use tools with insulated handles.
c. Wear rubber gloves and boots.
d. Do not lay tools or metal parts on top of batteries.
e. Disconnect the charging source prior to connecting or disconnecting battery terminals.
f. Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance.
CAUTION: The UPS contains internal batteries and may present a shock hazard even when disconnected from AC power.
CAUTION: Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may exist between battery terminals and ground. Test before touching.
What is the Radio Frequency Warning for the SCHNEIDER ELECTRIC APC SMV750A?
What is included in the inventory with the SCHNEIDER ELECTRIC APC SMV750A?
USB cable
Software, User documentation
What are the product features of the SCHNEIDER ELECTRIC APC SMV750A?
A ON/OFF button
B RS-232
C USB port
D Fan/ventilation hole
E Battery connector
F AC Inlet
G Fuse
H Battery backup outlets with surge protection
I Output breaker
J Intelligent Slot
K Dry contact
L EPO
How do I interpret the front panel LCD on the SCHNEIDER ELECTRIC APC SMV750A?
| Number | Status |
|---|---|
| 1 | On Line mode |
| 2 | Battery mode |
| 3 | Automatic Voltage Regulation |
| 4 | Battery capacity |
| 5 | Load capacity |
| 6 | UPS status |
| 7 | Power ON/OFF button |
What are the installation requirements for the SCHNEIDER ELECTRIC APC SMV750A?
Before installing the UPS, ensure the input breaker on the UPS upstream is Type C rated at 16A.
UPS MUST be installed indoor with a controlled environment free of excessive dust, corrosive air or conductive dust.
Do NOT install in outdoor.
Keep out of direct sun light, water and heat sources.
Place the unit on the stable floor.
How do I connect the battery on the SCHNEIDER ELECTRIC APC SMV750A?
Connect the battery by pulling the battery handle up, and then pushing it into the unit. The battery connector is located on the rear panel.
– Connect prior to operation.
– Disconnect prior to transportation. Turn OFF the UPS and remove input power cable before disconnecting the battery connector.
What are the guidelines for connecting equipment to the SCHNEIDER ELECTRIC APC SMV750A?
Connect your equipment to the UPS, but avoid using extension cords.
Do NOT connect printers, heaters, or copiers to the UPS.
During a power outage or other AC problems, the Battery Backup outlets receive power for a limited time from the Easy UPS.
How do I properly power on the SCHNEIDER ELECTRIC APC SMV750A for the first time?
1. Plug the Easy UPS power cord directly into a wall outlet, not into a surge protector or power strip.
2. Press the ON/OFF button to turn on the unit. Press the On/Off button for 1-3 seconds. The buzzer sound confirms that the Easy UPS is on and providing power to outlets.
3. The Easy UPS should charge the battery for at least 8 hours to ensure sufficient runtime.
How can I use the cold start feature on the SCHNEIDER ELECTRIC APC SMV750A?
How does the dry contact interface on the SCHNEIDER ELECTRIC APC SMV750A work?
The dry contact interface will be activated when the UPS is operating in one of the conditions shown in the table below. The interface is activated as follows:
When the UPS detects a battery failure, PIN1-2 of a dry contact will be activated.
When the UPS is operating in AC mode, PIN1-3 of a dry contact will be activated.
| When UPS is operating in… | Activate |
|---|---|
| 1. AC mode | PIN1-3 |
| 2. Backup mode | N/A |
| 3. Standby mode | N/A |
| 4. AC mode and Battery weak | PIN1-2 & PIN1-3 |
| 5. Standby mode and Battery weak | PIN1-2 |
What are the technical specifications for the SCHNEIDER ELECTRIC APC SMV750A and other models in the series?
| Model | SMV750A | SMV1000A | SMV1500A | SMV2000CA | SMV3000CA | |
|---|---|---|---|---|---|---|
| Input | Voltage | 120VAC | ||||
| Voltage range | 83-145Vac±5Vac | |||||
| Connection | NEMA5-15P | NEMA5-20P | NEMA5-30P | |||
| Frequency Range | 45-65 Hz (auto sensing) ±1Hz | |||||
| Output | UPS Capacity (total) | 750VA / 525W | 1000VA / 700W | 1500VA / 1050W | 2000VA / 1400W | 3000VA / 2100W |
| Rated Voltage | 120VAC | |||||
| Transfer time | Typical 2-6 ms, 12ms max. | |||||
| Waveform | Pure Sine Wave | |||||
| Battery | Type (maintenance-free) | 12V/7Ah x 2 lead acid | 12V/7Ah x 2 lead acid | 12V/10Ah x 2 lead acid | 12V/7Ah x 4 lead acid | 12V/9Ah x 4 lead acid |
| Charging time | 4-6 hours recover to 90% capacity | |||||
| Physical | Dimension (DxWxH, mm) | 410 x 160 x 220 | 455 x 180 x 240 | |||
| Net Weight (kg) | 15 | 18 | 20 | 28 | 31.5 | |
| Gross Weight (kg) | 18 | 21 | 23 | 32 | 35.5 | |
| Environment | Operating temperature & Humidity | 0-95% RH @ 0-40°C (non-condensing) | ||||
| Noise level | Less than 45 dB | |||||
| Enclosure type | IP Rating | IP20 | ||||
What do the audible indicators and status icons on the SCHNEIDER ELECTRIC APC SMV750A mean?
| If the Easy UPS… | Possible cause… |
|---|---|
| Beeps every 2 seconds. | Easy UPS is running on battery. You should consider saving any work in progress. |
| Continuous Beeping. | Low battery condition and battery run-time is very low. Promptly save any work in progress, exit all open applications, and shut down the operating system. |
| Continuous tone with LCA illuminated. | Battery Backup outputs are overloaded. |
| Continuous tone with Err illuminated. a. Press ON/OFF button for 1-3 seconds to mute the alarm. b. Continuous tone will persist until battery LOW. (<11Vdc each BATT) |
Err 01: Fan fault detected Err 02: Inverter short Err 03: Inverter over voltage Err 04: Emergency power off, EPO |
| Beeps every 4 seconds with battery icon illuminated. | The battery is near the end of useful life or damaged. |
What should I do if my SCHNEIDER ELECTRIC APC SMV750A will not turn on?
Problem: The Easy UPS has not been turned on.
Solution: Press the ON/OFF button.
Problem: The Easy UPS is not connected to AC power, there is no AC power available at the wall outlet, or the AC power is experiencing a brownout or over voltage condition.
Solution: Make sure the power cord is securely connected to the wall outlet, and that there is AC power available at the wall outlet. Where applicable, check that the wall outlet is switched on or input fuse works properly.
Problem: The battery is disconnected.
Solution: Refer to the installation instructions to ensure the battery is connected.
What should I do if connected equipment loses power when using the SCHNEIDER ELECTRIC APC SMV750A?
Problem: An Easy UPS overload condition has occurred.
Solution: Remove all nonessential equipment connected to the outlets. One at a time reconnect equipment to the Easy UPS.
Problem: The Easy UPS battery is completely discharged.
Solution: Connect the Easy UPS to AC power and recharge for 10 hours.
Problem: The Easy UPS may require service.
Solution: Contact Schneider Electric Technical Support.
Why is my SCHNEIDER ELECTRIC APC SMV750A operating on battery power even when connected to AC power?
Problem: The plug has partially pulled out of the wall outlet, the wall outlet is no longer receiving AC power, or the fuse has been blown.
Solution: Ensure that the plug is fully inserted into the wall outlet. Ensure that the wall outlet is receiving AC power by checking it with another device. Or replace the fuse.
What does the “Err 01: Fan fault detected” message mean on my SCHNEIDER ELECTRIC APC SMV750A?
What does the “Err 02: Inverter short detected” message mean on my SCHNEIDER ELECTRIC APC SMV750A?
What does the “Err 03: Inverter over voltage detected” message mean on my SCHNEIDER ELECTRIC APC SMV750A?
What does the “Err 04: Emergency power off, EPO” message mean on my SCHNEIDER ELECTRIC APC SMV750A?
Why is my SCHNEIDER ELECTRIC APC SMV750A beeping every 4 seconds?
Problem: The battery is disconnected.
Solution: Make sure the battery connector in the rear panel is connected.
Problem: The battery is near the end of useful life or damaged.
Solution: Contact Schneider Electric Technical Support if the Easy UPS remains beeping with the battery connector securely connected.
What can I do if my SCHNEIDER ELECTRIC APC SMV750A has an inadequate battery runtime?
Problem: The battery is not fully charged.
Solution: Leave the Easy UPS connected to AC power for 10 hours while the battery charges to full capacity.
Problem: The battery is near the end of useful life and should be replaced.
Solution: As a battery ages, the runtime capability decreases. Contact technical support about replacing the battery.
What steps should I follow if my SCHNEIDER ELECTRIC APC SMV750A requires service?
If the unit requires service, do not return it to the dealer. Follow these steps:
1. Review the Troubleshooting section of the manual to eliminate common problems.
2. If the problem persists, contact Schneider Electric IT (SEIT) Customer Support. Note the model number, serial number, and date of purchase. The model and serial numbers are located on the rear panel of the unit. A technician will attempt to solve the problem over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#).
3. Pack the unit in the original packaging whenever possible to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty.
4. Always DISCONNECT THE UPS BATTERIES before shipping. The United States Department of Transportation (DOT), and the International Air Transport Association (IATA) regulations require that UPS batteries be disconnected before shipping. The internal batteries may remain in the UPS.
5. Write the RMA# provided by Customer Support on the outside of the package.
6. Return the unit by insured, pre-paid carrier to the address provided by Customer Support.