PCE INSTRUMENTS PCE-IV 370HR3 (01) Image

Free English PCE INSTRUMENTS PCE-IV 370HR3 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD PCE INSTRUMENTS PCE-IV 370HR3 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the general safety precautions for using the PCE INSTRUMENTS PCE-IV 370HR3?

Please follow these safety notes when using the PCE INSTRUMENTS PCE-IV 370HR3:

• This device may only be used in the way specified in this manual. If used otherwise, this may cause dangerous situations.

• Do not expose the device to extreme temperatures, direct sunlight, extreme air humidity or moisture.

• The case should only be opened by qualified personnel.

• Do not touch the instrument with wet hands.

• Do not expose the device to shocks or strong vibrations.

• You should not make any technical changes to the device.

• The appliance should only be cleaned with a damp cloth; use only pH-neutral cleaner without solvents or abrasives.

• The device must only be used with original PCE accessories or equivalent.

• Before each use, please inspect the case for damage. In case of any visible damage, please do not use the device.

• The device must not be used when the environmental conditions (temperature, air humidity, etc.) are outside the limit values stated in the specifications.

• Do not expose the instrument to explosive atmospheres.

• Do not use the endoscope near uninsulated current-carrying conductors.

• The instrument should never be placed with the user interface facing an object (e.g. keyboard side on a table).

• This product has been produced for industrial use only. Do not use it for medical or any other biological purposes.


What are the technical specifications of the PCE INSTRUMENTS PCE-IV 370HR3 main unit?

The general specifications for the PCE INSTRUMENTS PCE-IV 370HR3 main unit are as follows:

Feature Specification
Sensor CMOS
Resolution videos / pictures 640 x 480
Frame rate 30 fps
Lighting Automatic
White balance Fixed
Field of view 67°
Depth of field 1.5 … 10 cm
Bending radius 90 mm
Display 3.5″ (88.9 mm) TFT display
Interface Mini-USB 1.1, AV out
Memory 8 GB SD card
Compression format MPEG4
Video format ASF
Video output system NTSC / PAL
Picture format JPEG
Power supply Rechargeable 3.7 V Li-ion battery
Environmental conditions 0 … +60 °C
Weight 450 g (incl. carrying case)

What are the specific technical specifications for the PCE INSTRUMENTS PCE-IV 370HR3 camera head?

Feature Specification
Camera head diameter 6 mm
Camera Cable Length: 3 m; water proof
Swivel mechanism Camera head can be swivelled by 110° in all directions
Illumination LEDs on the front and on the side
Operating and storing temperature 0 … +60 °C
Weight 800 g

What are the functions of the keys on the main unit of the PCE INSTRUMENTS PCE-IV 370HR3?

Key Function
A – power button Turns the device on or off.
B – photo button Takes a picture.
C – video button Starts or stops video recording.
D – up button Navigates up in menus.
E – down button Navigates down in menus.
F – OK button Confirms a selection.
G – escape button Zooms, mirrors image, or exits a menu.
H – illumination switch Adjusts light intensity.
I – SD card slot Slot for the memory card.
J – AV out Port for video output.
K – USB interface Port for USB connection.
L – mains connection Port for the mains adaptor.
M – Display Shows the camera view and menus.
N – camera cable/tube Connection point for the camera cable.
O – reset button Resets the device to factory defaults.

How do I get started with the PCE INSTRUMENTS PCE-IV 370HR3?

To start using your PCE INSTRUMENTS PCE-IV 370HR3, follow these steps:

1. Connect the camera cable to the display unit and screw it tightly. Ensure the indication on the connector is on the upper side.

2. Press and hold the power button for approximately 5 seconds to turn on the device.

3. The display will show the live camera view, SD card capacity, and battery status.

To turn off the device, press and hold the power button for 3 to 5 seconds.


How do I take a picture or record a video with the PCE INSTRUMENTS PCE-IV 370HR3?

Take a picture:

To take a picture of the current image, simply press the photo button. The picture is automatically stored on the SD card. The device then returns to the standard viewing mode.

Record a video:

To start recording a video, press the video button. An indication will appear on the display. To stop recording, press the video button again. The video is automatically stored on the SD card.

Zoom and Mirror:

During live view, you can press the escape button (ESC) to zoom in (2x digital zoom). If you press and hold the ESC button for a few seconds, the image on the screen will be mirrored.


How can I view and delete saved pictures and videos on the PCE INSTRUMENTS PCE-IV 370HR3?

View Data:

From the standard viewing mode, press the up or down button to enter the playback screen. Use these buttons to navigate through all stored pictures and videos, which are sorted by date of recording.

Delete a Single File:

1. While viewing your files, select the picture or video you want to delete.

2. Press the OK button. A confirmation window will appear.

3. Use the up or down button to choose “Yes” to delete or “No” to cancel.

4. Press the OK button to confirm your selection.


How do I access and change settings on the PCE INSTRUMENTS PCE-IV 370HR3?

Press the OK button in standard viewing mode to enter the settings menu. You can navigate the following options using the up and down buttons and select with the OK button:

DELETE ALL FILES: Select this and choose “Yes” to erase all files from the SD card.

AV OUTPUT: Connect the AV out to an external display, then select this option. The endoscope’s display will turn black, and the image will be shown on the external unit. Press OK again to exit this mode.

DATE / TIME: Use the up/down buttons to move between year, month, day, hours, minutes, and seconds. Use the photo and video buttons to adjust the values. You can also choose “Yes” or “No” to display the date and time on recordings.

LANGUAGE: Select your desired language from the list and press OK to confirm.

TV SYSTEM: Choose between “PAL” and “NTSC” video output formats.

AUTO POWER OFF: Select a time duration after which the device will automatically shut down if idle.

Reset: To reset the device to factory default settings, press the physical reset button on the back of the device.


What are the specific safety precautions for the PCE INSTRUMENTS PCE-IV 370HR3 articulating camera head?

When using the 360° articulating camera head, please mind the following additional safety notes:

• To avoid dangerous situations, make sure the probe does not get in touch with inflammable liquids or gases.

• Do not disassemble the device as this can cause damage and electric shocks.

• To protect the camera module, make sure the protection ring is on the camera head as long as no accessories are in use.

• Do not bend the articulating camera head by hand. Only use the joystick to adjust the angle.

• Do not expose the device to extreme temperatures (use only between 0 and +60 °C), direct sunlight, extreme air humidity or moisture. Store it in a cool, dry, sufficiently ventilated place.

• If you coil up the camera cable for storing, make sure the diameter is at least 15 cm and that the camera head is in a straight position.

• Do not expose the camera head to mechanical strains and stresses.


How do I operate the 360° articulating camera head on the PCE INSTRUMENTS PCE-IV 370HR3?

Hold the device with one hand and use your thumb to operate the joystick and the function keys (Rotation, Light, Boost). Use your index finger to operate the boost key on the front of the handle.

Use the joystick to adjust the swiveling angle and direction of the camera head. The camera head can be swiveled by 110° in all directions.


What are the functions of the special keys on the PCE INSTRUMENTS PCE-IV 370HR3 articulating camera head?

The articulating camera head includes several special function keys:

Boost key: Use this key in dark environments to lighten up the image. For a clear image, hold the camera cable steady when using this function.

Rotation key: Use this key to rotate the image by 90° increments. This is useful when trying to read an inscription completely.

Light key: When using the mirror attachment, this key improves the vision by reducing impediments from particles, dust, etc., creating a “particle free” function.


How do I attach the mirror accessory to the PCE INSTRUMENTS PCE-IV 370HR3 camera head?

Follow these steps to attach the mirror:

1. Unscrew and remove the thread protection ring from the camera head.

2. Screw the separate assembly ring down to the bottom of the threads.

3. Screw the mirror attachment onto the thread until the thread is completely covered.

4. Align the lateral LED opening of the mirror attachment so that the side LEDs are uncovered.

5. Turn the assembly ring upwards to press against the mirror attachment, fixing it in place.

6. Press the light key to activate the lateral light for side viewing.

Note: Steps 4 and 5 may need to be repeated to achieve the correct alignment.


How should I handle and care for the HR camera probe on the PCE INSTRUMENTS PCE-IV 370HR3?

• Do not apply force to the end of the cable or bend it sharply. This can deteriorate your vision and damage the probe.

• When you roll up the cable, the inner diameter must be at least 15 cm.

• Put the protection ring back on and tighten it when not using the device for a longer period of time.

• Do not crash the probe head.

• Ensure the camera does not come into contact with lead-free petrol, diesel oil, machine oil, brake fluid, transmission oil, or water.

• Do not screw accessories on too tightly. Only screw them slightly until they are fixed.

• To clean the camera head, use the cleaning liquid and swabs provided in a cleaning kit.


What should I do for battery disposal for the PCE INSTRUMENTS PCE-IV 370HR3?

For the disposal of batteries, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD PCE INSTRUMENTS PCE-IV 370HR3 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.