What do the warning symbols indicate?
The warning symbols indicate a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage.
What do the specific signs mean?
The Laser beam sign indicates potential Laser beam hazard.
The Resolution prohibition sign indicates prohibition when there is a risk of minor injury from electrical shock or other source if the product is disassembled.
What are the safety precautions regarding laser radiation and product disassembly?
Do not expose your eyes to the laser radiation either directly (i.e., after reflection from a mirror or shiny surface). Loss of sight may possibly occur in case of the exposure to laser high power density.
Do not disassemble the product. Doing so may cause the laser beam to leak, resulting in the danger of visual impairment.
What precautions should be taken for the installation environment?
Do not use the product in environments where it can be exposed to inflammable/explosive gas.
To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices.
What precautions should be taken for power supply and wiring?
Use only products that have been made expressly for the Controller.
High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage.
Always turn off the power of the unit before connecting or disconnecting cables.
What are the installation instructions?
Make sure to tighten all installation screws securely (tightening torque: M3, 0.5N·m).
What other rules should be followed for product handling and disposal?
Do not attempt to disassemble, deform by pressure, incinerate, repair, or modify this product.
When disposing of the product, treat as industrial waste.
If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, immediately stop using the product, turn off the power, and consult your dealer.
What locations should be avoided for product installation?
Do not install the product in locations subjected to the following conditions:
- Surrounding air temperature outside the rating
- Rapid temperature fluctuations (causing condensation)
- Relative humidity outside the range of 35 to 85%
- Presence of corrosive or flammable gases
- Presence of dust, salt, or iron particles
- Direct vibration or shock
- Reflection of intense light (such as other laser beams, electric arc-welding machines, or ultra-violet light)
- Direct sunlight or near heaters
- Water, oil, or chemical fumes or spray, or mist atmospheres
- Strong magnetic or electric field
What are the power supply and wiring instructions for correct use?
Use only products that have been made expressly for the Controller.
To extend the cable from the sensor head, an optional extension cable (ZX2-XCR) must be used.
What is the warm-up procedure for the Controller?
After turning on the power supply, allow the Controller to stand for at least 10 minutes before use. The circuits are unstable immediately after the power supply is turned on and attempting measurement may result in inconsistent measurement values.
What are the maintenance and inspection procedures?
Always turn off the power of the unit before connecting or disconnecting cables.
Do not use thinner, alcohol, benzene, acetone, or kerosene to clean the sensor.
If considerable foreign matter or dust collects on the front of sensor, use a blower brush (for camera lenses) to blow off the foreign matter. Avoid blowing it off with your breath. For a small amount of foreign matter or dust, gently wipe with a soft cloth. Do not wipe hard. If the surface is damaged, false detection may result.
What are the considerations for sensing objects with the Reflective Type Sensor Head?
The product cannot accurately measure the following types of objects: Transparent objects, objects with an extremely low reflective sensor ratio, objects smaller than the spot diameter, objects with a large curvature, excessively inclined objects, etc.
Set scaling regularly to maintain accurate detection.
How can mutual interference be prevented?
Inserting a calculation unit between amplifier units can prevent mutual interference between sensor heads. However, this may not work efficiently if the amount of light received by one sensor head is saturated due to the luster of work-pieces and a laser beam from the other sensor head is input. If you are interested in installing a calculation unit to prevent mutual interference, carry out a test using the actual system beforehand.
What items are included in the package?
The package contains:
- Sensor head x1
- Ferrite core x1
- FDA Certification label x1
- Manual (this paper) x1
- Laser explanatory label x1 (Japanese, English)
What are the specifications of the ZX2-LD sensor head?
| Item | ZX2-LD50L | ZX2-LD50 | ZX2-LD100L | ZX2-LD100 |
|---|---|---|---|---|
| Applicable Amplifier | ZX2-LDA | |||
| Measuring center distance | 50mm | 100mm | ||
| Measuring range | ±10mm | ±35mm | ||
| Light source | Red semiconductor laser (λ=660nm, 1mW max., IEC/EN 60825-1 Class1, FDA Class1) | |||
| Beam diameter (*1) | Approx.60µmx2.6mm | Approx.60µm-dia. | Approx.110µmx2.7mm | Approx.110µm-dia. |
| Resolution (*2) | 1.5µm | 5µm | ||
| Linearity (*3) Full range | ±0.1%F.S. | ±0.1%F.S. | ||
| Linearity (*3) Half range | ±0.05%F.S. (40-50 mm) | ±0.05%F.S. (65-100 mm) | ||
| Temperature characteristic (*4) | 0.02%F.S./°C | |||
| Surrounding air temperature | Operating: 0 to 50°C, Storage: -15 to 70°C (with no icing or condensation) | |||
| Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |||
| Operating ambient illumination | Illuminance on receiving optical side 10,000 lx (incandescent light) | |||
| Dialectic strength | 1,000 VAC, 50/60 Hz for 1 min | |||
| Vibration resistance (destructive) | 10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions | |||
| Shock resistance (destructive) | 300 m/s² 3 times each in six directions (up/down, left/right, forward/backward) | |||
| Degree of protection | IP67 | |||
| Materials | PBT (Case), Glass (Lensfilter), PVC (Cable) | |||
| Weight (packed state) | Approx. 160g (sensor head: Approx. 75g) | |||
*1 Beam diameter: Value of minimum diameter in measuring range. The typical value at the measuring center distance is shown. Defined as 1/e² (13.5%) of the center intensity. The beam diameter may sometimes be affected by the ambient condition of the object such as leaked light from the main beam.
*2 Resolution: Fluctuation width of linear outputs when connected to Amplifier Unit (With response time set to 128ms and the standard work (white ceramics) placed at the measuring center distance). This value is repetition accuracy of the static condition work, and not distance accuracy. In a strong electromagnetic field, the performance of resolution might not be able to be satisfied.
*3 Linearity: The error in relation to the ideal displacement output straight line when the standard work is measured.
*4 Temperature characteristic: Value obtained when the sensor and object (standard work) are fixed with an aluminum jig. (Measured at the measuring center distance)
How do I install the sensor heads?
Fix the Reflective type sensor head with screws (M3). The tightening torque is M3, 0.5Nm.
When mounting a Sensor Head, take care not to touch the emitter and receiver. Adhesion of finger marks may hinder correct measurements. If you have touched them, wipe them with a clean soft cloth.
How do I connect the sensor head?
A ferrite core (supplied with the sensor head) must be attached to the sensor cable. The ferrite cores can be connected within 100 mm from the sensor.
CLICK HERE TO DOWNLOAD OMRON ZX2-LD50L (01) PDF MANUAL