What are the laser safety warnings for the ZX2-LD sensor head?
Do not expose your eyes to the laser radiation either directly (i.e., after reflection from a mirror or shiny surface). Loss of sight may possibly occur in case of the exposure to laser high power density.
Do not disassemble the product. Doing so may cause the laser beam to leak, resulting in the danger of visual impairment.
The ZX2-LD has an explanatory label on the side of the sensors with the following information:
▲ WARNING
LASER RADIATION
Semiconductor Laser
Class 1 Laser Product
Maximum output: 1.0mW, Pulse width: 2ms
Wavelength: 660nm
JIS C 6802: 2014
How should the ZX2-LD be labeled for use in the USA?
When using a device equipped with the ZX2-LD in the U.S., attach an FDA certification label on the sensor at the correct location as indicated in the product documentation, and replace the explanatory label with corresponding Laser explanatory label (English).
What precautions should be taken regarding the installation environment?
Do not use the product in environments where it can be exposed to inflammable/explosive gas.
To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices.
What precautions should be taken regarding power supply and wiring?
Use only products that have been made expressly for the Controller.
High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage.
Always turn off the power of the unit before connecting or disconnecting cables.
How should the ZX2-LD be installed?
Make sure to tighten all installation screws securely (tightening torque: M3, 0.5N·m).
What general rules should be followed for safe use of the product?
Do not attempt to disassemble, deform by pressure, incinerate, repair, or modify this product.
When disposing of the product, treat as industrial waste.
If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, immediately stop using the product, turn off the power, and consult your dealer.
Where should the ZX2-LD sensor head not be installed?
Do not install the product in locations subjected to the following conditions:
Surrounding air temperature outside the rating
Rapid temperature fluctuations (causing condensation)
Relative humidity outside the range of 35% to 85%
Presence of corrosive or flammable gases
Presence of dust, salt, or iron particles
Direct vibration or shock
Reflection of intense light (such as other laser beams, electric arc-welding machines, or ultra-violet light)
Direct sunlight or near heaters
Water, oil, or chemical fumes or spray, or mist atmospheres
Strong magnetic or electric field
How should the sensor head be connected to the controller?
Use only products that have been made expressly for the Controller.
To extend the cable from the sensor head, an optional extension cable (ZX2-XCR) must be used.
What is the warm-up procedure for the ZX2-LD?
After turning on the power supply, allow the Controller to stand for at least 10 minutes before use. The circuits are unstable immediately after the power supply is turned on and attempting measurement may result in inconsistent measurement values.
How should maintenance and inspection be performed for the ZX2-LD?
Always turn off the power of the unit before connecting or disconnecting cables.
Do not use thinner, alcohol, benzene, acetone, or kerosene to clean the sensor.
If considerable foreign matter or dust collects on the front of sensor, use a blower brush (for camera lenses) to blow off the foreign matter. Avoid blowing it off with your breath. For a small amount of foreign matter or dust, gently wipe with a soft cloth. Do not wipe hard. If the surface is damaged, false detection may result.
What types of objects can the sensor not accurately measure?
The product cannot accurately measure the following types of objects:
Transparent objects
Objects with an extremely low reflective sensor ratio
Objects smaller than the spot diameter
Objects with a large curvature
Excessively inclined objects, etc.
Set scaling regularly to maintain accurate detection.
How can mutual interference be prevented?
Inserting a calculation unit between amplifier units can prevent mutual interference between sensor heads. However, this may not work efficiently if the amount of light received by one sensor head is saturated because of the luster of work-pieces and a laser beam from the other sensor head is input. If you are interested in installing a calculation unit in order to prevent mutual interference, carry out a test using the actual system beforehand.
What are the specifications of the ZX2-LD sensor head?
The specifications of the ZX2-LD sensor head are as follows:
| Item | ZX2-LD50L | ZX2-LD50 | ZX2-LD100L | ZX2-LD100 |
|---|---|---|---|---|
| Applicable Amplifier | ZX2-LDA | |||
| Measuring center distance | 50mm | 100mm | ||
| Measuring range | ±10mm | ±35mm | ||
| Light source | Red semiconductor laser (λ=660nm, 1mW max., IEC/EN 60825-1 Class1. FDA Class1) | |||
| Beam diameter (*1) | Approx.60umx2.6mm | Approx.60um-dia. | Approx.110umx2.7mm | Approx.110um-dia. |
| Resolution (*2) | 1.5µm | 5μm | ||
| Linearity Full range (*3) | ±0.1%F.S. | ±0.1%F.S. | ±0.1%F.S. | ±0.1%F.S. |
| Linearity Half range (*3) | ±0.05%F.S. (40-50 mm) | ±0.05%F.S. (40-50 mm) | ±0.05%F.S. (65-100 mm) | ±0.05%F.S. (65-100 mm) |
| Temperature characteristic (*4) | 0.02%F.S./°C | |||
| Surrounding air temperature | Operating: 0 to 50°C, Storage: -15 to 70°C (with no icing or condensation) | |||
| Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | |||
| Operating ambient illumination | Illuminance on receiving optical side 10,000 lx (incandescent light) | |||
| Dialectic strength | 1,000 VAC, 50/60 Hz for 1 min | |||
| Vibration resistance (destructive) | 10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions | |||
| Shock resistance (destructive) | 300 m/s² 3 times each in six directions (up/down, left/right, forward/backward) | |||
| Degree of protection | IP67 | |||
| Materials | PBT (Case), Glass (Lensfilter), PVC(Cable) | |||
| Weight (packed state) | Approx. 160g (sensor head: Approx. 75g) | |||
*1 Beam diameter: Value of minimum diameter in measuring range. The typical value at the measuring center distance is shown. Defined as 1/e² (13.5%) of the center intensity. The beam diameter may sometimes be affected by the ambient condition of the object such as leaked light from the main beam.
*2 Resolution: Fluctuation width of linear outputs when connected to Amplifier Unit (With response time set to 128ms and the standard work (white ceramics) placed at the measuring center distance) This value is repetition accuracy of the static condition work, and not distance accuracy. In a strong electromagnetic field, the performance of resolution might not be able to be satisfied.
*3 Linearity: The error in relation to the ideal displacement output straight line when the standard work is measured.
*4 Temperature characteristic: Value obtained when the sensor and object (standard work) are fixed with an aluminum jig. (Measured at the measuring center distance)
How should the sensor head be installed on a surface?
Fix the Reflective type sensor head with screws (M3). (tightening torque: M3, 0.5Nm).
When mounting a Sensor Head, take care not to touch the emitter and receiver. Adhesion of finger marks may hinder correct measurements. If you have touched them, wipe them with a clean soft cloth.
How should the sensor cable be connected?
A ferrite core (supplied with the sensor head) must be attached to the sensor cable. The ferrite cores can be connected within 100 mm from the sensor.