OMRON ZX2-LD50 (01) Image

FREE ENGLISH OMRON ZX2-LD50 (01) PDF USER GUIDE
FREE ENGLISH OMRON ZX2-LD50 (01) PDF USER MANUAL
FREE ENGLISH OMRON ZX2-LD50 (01) PDF OWNER GUIDE
FREE ENGLISH OMRON ZX2-LD50 (01) PDF OWNER MANUAL
FREE ENGLISH OMRON ZX2-LD50 (01) PDF REFERENCE GUIDE
FREE ENGLISH OMRON ZX2-LD50 (01) PDF INSTRUCTION GUIDE
FREE ENGLISH OMRON ZX2-LD50 (01) PDF REFERENCE MANUAL
FREE ENGLISH OMRON ZX2-LD50 (01) PDF INSTRUCTION MANUAL
FREE ENGLISH OMRON ZX2-LD50 (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD OMRON ZX2-LD50 (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What are the installation environment precautions for this product?

Do not use the product in environments where it can be exposed to inflammable/explosive gas. To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices.


What are the power supply and wiring precautions for this product?

Use only products that have been made expressly for the Controller. High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage. Always turn off the power of the unit before connecting or disconnecting cables.


What are the installation precautions for this product?

Make sure to tighten all installation screws securely (tightening torque: M3, 0.5N·m).


What are the general safety rules for this product?

Do not attempt to disassemble, deform by pressure, incinerate, repair, or modify this product. When disposing of the product, treat as industrial waste. If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, immediately stop using the product, turn off the power, and consult your dealer.


What locations should be avoided when installing the product to ensure correct use?

Do not install the product in locations subjected to the following conditions:

Surrounding air temperature outside the rating

Rapid temperature fluctuations (causing condensation)

Relative humidity outside the range of 35 to 85%

Presence of corrosive or flammable gases

Presence of dust, salt, or iron particles

Direct vibration or shock

Reflection of intense light (such as other laser beams, electric arc-welding machines, or ultra-violet light)

Direct sunlight or near heaters

Water, oil, or chemical fumes or spray, or mist atmospheres

Strong magnetic or electric field


What are the power supply and wiring precautions for correct use?

Use only products that have been made expressly for the Controller. To extend the cable from the sensor head, an optional extension cable (ZX2-XCR) must be used.


What is the warming up procedure for the product?

After turning on the power supply, allow the Controller to stand for at least 10 minutes before use. The circuits are unstable immediately after the power supply is turned on and attempting measurement may result in inconsistent measurement values.


What are the maintenance and inspection guidelines for the product?

Always turn off the power of the unit before connecting or disconnecting cables. Do not use thinner, alcohol, benzene, acetone, or kerosene to clean the sensor. If considerable foreign matter or dust collects on the front of sensor, use a blower brush (for camera lenses) to blow off the foreign matter. Avoid blowing it off with your breath. For a small amount of foreign matter or dust, gently wipe with a soft cloth. Do not wipe hard. If the surface is damaged, false detection may result.


What types of sensing objects should be considered for the reflective type sensor head?

The product cannot accurately measure the following types of objects: Transparent objects, objects with an extremely low reflective sensor ratio, objects smaller than the spot diameter, objects with a large curvature, excessively inclined objects, etc. Set scaling regularly to maintain accurate detection.


How can mutual interference be addressed with this product?

Inserting a calculation unit between amplifier units can prevent mutual interference between sensor heads. However, this may not work efficiently if the amount of light received by one sensor head is saturated because of the luster of work-pieces and a laser beam from the other sensor head is input. If you are interested in installing a calculation unit in order to prevent mutual interference, carry out a test using the actual system beforehand.


What are the specifications for the ZX2-LD sensor heads?

The specifications for the ZX2-LD sensor heads are as follows:

Item Model ZX2-LD50L ZX2-LD50 ZX2-LD100L ZX2-LD100
Applicable Amplifier ZX2-LDA
Measuring center distance Units 50mm 100mm
Measuring range ±10mm ±35mm
Light source Red semiconductor laser (λ=660nm, 1mW max., IEC/EN 60825-1 Class1. FDA Class1)
Beam diameter (*1) Approx.60µm x 2.6mm Approx.60µm-dia. Approx.110µm x 2.7mm Approx.110µm-dia.
Resolution (*2) 1.5µm 5µm
Linearity Full range (*3) ±0.1%F.S. ±0.15%F.S. ±0.1%F.S. ±0.15%F.S.
Half range (*3) ±0.05%F.S. (40-50 mm) ±0.1%F.S. (40-50 mm) ±0.05%F.S. (65-100 mm) ±0.1%F.S. (65-100 mm)
Temperature characteristic (*4) 0.02%F.S./°C
Surrounding air temperature Operating: 0 to 50°C, Storage: -15 to 70°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Operating ambient illumination Illuminance on receiving optical side 10,000 lx (incandescent light)
Dialectic strength 1,000 VAC, 50/60 Hz for 1 min
Vibration resistance (destructive) 10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions
Shock resistance (destructive) 300 m/s² 3 times each in six directions (up/down, left/right, forward/backward)
Degree of protection IP67
Materials PBT (Case), Glass (Lensfilter), PVC(Cable)
Weight (packed state) Approx. 160g (sensor head: Approx. 75g)

F.S.: Full scale of measurement

(*1) Beam diameter: Value of minimum diameter in measuring range. The typical value at the measuring center distance is shown. Defined as 1/e² (13.5%) of the center intensity. The beam diameter may sometimes be affected by the ambient condition of the object such as leaked light from the main beam.

(*2) Resolution: Fluctuation width of linear outputs when connected to Amplifier Unit (With response time set to 128ms and the standard work (white ceramics) placed at the measuring center distance). This value is repetition accuracy of the static condition work, and not distance accuracy. In a strong electromagnetic field, the performance of resolution might not be able to be satisfied.

(*3) Linearity: The error in relation to the ideal displacement output straight line when the standard work is measured.

(*4) Temperature characteristic: Value obtained when the sensor and object (standard work) are fixed with an aluminum jig. (Measured at the measuring center distance)


How should sensor heads be installed?

Fix the Reflective type sensor head with screws (M3). Tightening torque is 0.5Nm.


What precautions should be taken when mounting a Sensor Head?

When mounting a Sensor Head, take care not to touch the emitter and receiver. Adhesion of finger marks may hinder correct measurements. If you have touched them, wipe them with a clean soft cloth.


How should the ferrite core be attached to the sensor cable?

A ferrite core (supplied with the sensor head) must be attached to the sensor cable. The ferrite cores can be connected within 100 mm from the sensor.