Free English MONESSEN AVFL42PIF-BU (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD MONESSEN AVFL42PIF-BU (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What safety precautions should I take if I smell gas around my MONESSEN AVFL42PIF-BU?
If you smell gas while using the MONESSEN AVFL42PIF-BU, follow these steps immediately:
Do NOT try to light any appliance.
Do NOT touch any electrical switch.
Do NOT use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor’s phone and follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
What are the BTU specifications and orifice sizes for the MONESSEN AVFL42PIF-BU?
The following table outlines the input ratings and orifice specifications for the MONESSEN AVFL42PIF-BU at elevations from 0 to 2000 feet:
| Model | Fuel Type | Maximum Input BTU/h | Minimum Input BTU/h | Orifice Size (DMS) |
|---|---|---|---|---|
| MONESSEN AVFL42PIF-BU | Propane | 33,000 | 26,000 | .070 (#50) |
Note: For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level.
What are the clear space requirements for the MONESSEN AVFL42PIF-BU?
To ensure safe operation of the MONESSEN AVFL42PIF-BU, a clear space of 3 feet must be maintained in front of the appliance.
Do not place combustible objects in front of the appliance as high temperatures may start a fire.
Avoid placing candles, electronics, and other heat-sensitive objects on the mantel or hearth as heat may damage these objects.
What is considered “Over Firing” in the MONESSEN AVFL42PIF-BU?
The MONESSEN AVFL42PIF-BU is considered to be over firing if the flames are contacting the top of the firebox. If this occurs, you must call a qualified service technician to service the appliance.
What should be checked before lighting the MONESSEN AVFL42PIF-BU for the first time?
Before operating the MONESSEN AVFL42PIF-BU for the first time, a qualified service technician must:
Verify all shipping materials have been removed from inside and/or underneath the firebox.
Review proper placement of crushed glass media.
Ensure that there are no gas leaks.
Ensure that the air deflection glass is seated in the proper position.
How do I light the burner on the MONESSEN AVFL42PIF-BU using the Intermittent Pilot Ignition (IPI) system?
To light the MONESSEN AVFL42PIF-BU:
1. Smell all around the appliance area for gas, including near the floor as some gas is heavier than air.
2. Wait five minutes to clear out any gas. If you smell gas, stop and follow safety procedures. If you do not smell gas, proceed to the next step.
3. To light the burner, use your specific control method:
If equipped with a wall switch: Turn the ON/OFF switch to ON.
If equipped with a remote or wall control: Press the ON or FLAME button.
If equipped with a thermostat: Set the temperature to the desired setting.
4. If the appliance does not light after three tries, call your service technician or gas supplier.
How do I turn off the gas to the MONESSEN AVFL42PIF-BU?
To turn off the MONESSEN AVFL42PIF-BU:
If using a wall switch: Turn the ON/OFF switch to OFF.
If using a remote or wall control: Press the OFF button.
If using a thermostat: Set the temperature to the lowest setting.
What is the initial break-in procedure for the MONESSEN AVFL42PIF-BU?
During the initial break-in of the MONESSEN AVFL42PIF-BU, follow these steps to cure the manufacturing materials:
The appliance should run three to four hours continuously on high.
Turn the appliance off and allow it to completely cool.
Notice: Open windows for air circulation during this process as some people may be sensitive to smoke and odors, and smoke detectors may activate.
How do I operate the MONESSEN AVFL42PIF-BU during a power outage?
The MONESSEN AVFL42PIF-BU features a battery backup system. To operate on battery power (DC):
1. Access the control cavity. Ensure the unit is off and cool. Lift the barrier screen off, remove logs or stone if installed, and remove crushed glass media and the deflection glass panel from the hearth pan.
2. Remove two screws securing the burner assembly, lift the burner, and place the two provided engine supports against the lower front space at the bottom of the face and slide them into the slots at the bottom of the engine assembly.
3. Locate the battery tray and insert four AA cell batteries. Polarity must be correct to avoid module damage.
4. Turn the appliance on using the wall switch or remote.
Note: Some functionality will be lost when using battery backup, including remote control (if the receiver is not powered), lights, or other auxiliary functions that require 110-120 VAC power.
What are the functions of the three positions on the Electronic Control Module (IFT2-ECM) of the MONESSEN AVFL42PIF-BU?
The MONESSEN AVFL42PIF-BU IFT2-ECM has a three-position selector switch:
OFF Position: The appliance will not respond to any commands from remote controls or the mobile app. The unit should be in this position during installation, service, or fuel conversion.
ON Position: The appliance will ignite and run continuously at the HIGH flame setting. No flame height adjustment is possible. A safety feature will automatically shut down the fireplace after 9 hours of continuous operation in this position.
REMOTE Position: This allows operation from the IntelliFire app or remote controls. The switch must be in this position to pair the module with a remote. A safety feature will automatically shut down the fireplace after 9 hours of continuous operation without receiving a command.
How do I manually shut off the MONESSEN AVFL42PIF-BU if the remote or wall switch malfunctions?
If the MONESSEN AVFL42PIF-BU will not turn off normally, you can manually shut it down using one of the following methods:
Unplug the appliance from the electrical source.
Locate the house circuit breaker for the appliance and turn it off.
Turn the reset switch located in the front face of the appliance to the OFF position.
What maintenance tasks are required for the MONESSEN AVFL42PIF-BU?
Maintenance for the MONESSEN AVFL42PIF-BU should be performed according to the following schedule:
| Task | Frequency | Performed By |
|---|---|---|
| Surrounds Maintenance | Annually | Homeowner |
| Remote Control Battery Check | Seasonally | Homeowner |
| Pilot Inspection and Cleaning | Annually | Qualified Service Technician |
| Log/Crushed Glass Media Inspection | Annually | Qualified Service Technician |
| Firebox Inspection | Annually | Qualified Service Technician |
| Control Compartment and Firebox Top Cleaning | Annually | Qualified Service Technician |
| Burner Ignition and Operation Check | Annually | Qualified Service Technician |
How do I troubleshoot common operational issues with the MONESSEN AVFL42PIF-BU?
Refer to this table for troubleshooting symptoms on the MONESSEN AVFL42PIF-BU:
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Remote control will not transmit | Batteries depleted or incorrect Child Lock mode | Verify batteries are functional; disengage Child Lock mode. |
| Control module will not take commands | Module not in REMOTE mode | Ensure module switch is set to REMOTE. |
| Appliance is on but will not shut off via remote | External wired wall switch is ON | Turn external wall switch to OFF or use the manual reset switch. |
| Odor from appliance | Manufacturing oils burning off or dust buildup | Run for 3-4 hours on high initially; have technician clean before each season. |
| Metallic noise | Metal expansion and contraction | No action necessary; this is normal and does not affect longevity. |
What do the LED error codes on the MONESSEN AVFL42PIF-BU IFT2-ECM indicate?
The IFT2-ECM module on the MONESSEN AVFL42PIF-BU uses red and green LED flashes to indicate specific errors:
2 Red / 1 Green: Pilot valve solenoid not detected or open pilot flame coil.
2 Red / 2 Green: Ignition feedback signal error, spark coil failure, or low-impedance short.
3 Red / 1 Green: Pilot sparks for 90 seconds but no flame rectification occurs (Appliance Safely Disabled).
4 Red / 1 Green: 110VAC power is incorrectly connected to the wall switch.
6 Red / 1 Green: Oxygen Depletion Sensor (ODS) error. Move the selector switch to OFF for 3 seconds, then back to REMOTE to clear.
8 Red / 1 Green: ECM error.
What are the guidelines for installing a TV above the MONESSEN AVFL42PIF-BU?
When installing a TV above the MONESSEN AVFL42PIF-BU, follow these minimum clearance guidelines:
Combustible Mantel: Minimum “A” dimension of 22.00 inches from the top of the appliance opening.
Non-Combustible Mantel: Minimum “A” dimension of 20.00 inches from the top of the appliance opening.
TV Height: A minimum height of 28 inches from the top of the appliance opening to the bottom of the TV is recommended.
Mantel Depth: A minimum mantel depth of 12 inches is typically required for heat protection.
Note: These are recommended guidelines and do not guarantee compliance with all TV manufacturers’ allowable operating temperatures. Actual temperatures should be validated at the time of installation.
CLICK HERE TO DOWNLOAD MONESSEN AVFL42PIF-BU (01) PDF DOCUMENT