What are the BTU specifications for the MONESSEN AVFL42NIF-BU?

The MONESSEN AVFL42NIF-BU is designed for Natural Gas (NG) at elevations between 0 to 2000 feet.

Model Fuel Type Maximum Input BTU/h Minimum Input BTU/h Orifice Size (DMS)
MONESSEN AVFL42NIF-BU Natural Gas (NG) 34,000 23,500 .1110(#34)

What should I do if I smell gas near the MONESSEN AVFL42NIF-BU?

If you smell gas while near the appliance, follow these safety steps immediately:

Do NOT try to light any appliance.

Do NOT touch any electrical switch.

Do NOT use any phone in your building.

Leave the building immediately.

Immediately call your gas supplier from a neighbor’s phone and follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.


Where is the installation of the MONESSEN AVFL42NIF-BU prohibited?

Do NOT install the MONESSEN AVFL42NIF-BU in a bedroom or bathroom. This appliance is an unvented gas-fired heater that uses air from the room in which it is installed, and provisions for adequate combustion and ventilation air must be provided.


How much clear space is required in front of the MONESSEN AVFL42NIF-BU?

A minimum of 3 feet of clear space is required in front of the MONESSEN AVFL42NIF-BU appliance. High temperatures can ignite combustible objects, so do not place candles, electronics, or other heat-sensitive objects on the mantel or hearth as the heat may damage them.


How do I prevent unintended operation of the MONESSEN AVFL42NIF-BU when it is not in use for an extended period?

To prevent the MONESSEN AVFL42NIF-BU from operating unintentionally during summer months, vacations, or trips, you should:

Remove the batteries from all remote controls.

Turn off any wall controls.

Unplug the 6 volt adapter plug.


What are the early signs of carbon monoxide poisoning from the MONESSEN AVFL42NIF-BU?

Early signs of carbon monoxide poisoning are similar to the flu and include headaches, dizziness, and nausea. If you experience these signs, obtain fresh air immediately and have the MONESSEN AVFL42NIF-BU serviced, as it may not be operating properly.


What is the initial break-in procedure for the MONESSEN AVFL42NIF-BU?

During the first use, the MONESSEN AVFL42NIF-BU should run for three to four hours continuously on high. This cures the materials used to manufacture the appliance. You should open windows for air circulation during this time, as the unit may release smoke and odors that could activate smoke detectors.


How do I light the MONESSEN AVFL42NIF-BU using the Intermittent Pilot Ignition (IPI) system?

Follow these lighting instructions for the MONESSEN AVFL42NIF-BU:

1. This appliance automatically lights the burner; do not try to light it by hand.

2. Before lighting, smell all around the appliance area for gas, including near the floor as some gas is heavier than air.

3. Wait five minutes to clear out any gas. If you smell gas, stop and follow the emergency safety procedures.

4. To light the burner if using a wall switch: Turn the ON/OFF switch to ON.

5. To light the burner if using a remote or wall control: Press the ON or FLAME button.

6. To light the burner if using a thermostat: Set the temperature to the desired setting.


How do I turn off gas to the MONESSEN AVFL42NIF-BU?

To shut down the gas supply to the appliance:

If equipped with a wall switch: Turn the ON/OFF switch to OFF.

If equipped with a remote or wall control: Press the OFF button.

If equipped with a thermostat: Set the temperature to the lowest setting.


How do I operate the MONESSEN AVFL42NIF-BU using battery power during a power outage?

The MONESSEN AVFL42NIF-BU includes a battery backup system for use during power outages:

1. Access the control cavity by lifting the barrier screen off the appliance. Remove logs, stone, or crushed glass media if necessary.

2. Remove the two screws securing the burner assembly, lift the assembly, and place the engine supports against the lower front space, sliding them into the slots at the bottom of the engine assembly.

3. Locate the battery tray and insert four AA cell batteries, ensuring correct polarity.

4. Turn the appliance on using the wall switch or the remote control.

Note: To preserve battery life, do not use the HI/LO flame or thermostat options during battery operation.


What do the different switch positions on the Electronic Control Module (IFT2-ECM) do for the MONESSEN AVFL42NIF-BU?

The IFT2-ECM has a three-position selector switch:

OFF Position: The appliance will not respond to commands. Use this position during installation, service, or fuel conversion. If the unit is running, switching to OFF will shut it down.

ON Position: The appliance will ignite and run continuously at the HIGH flame setting. It will not respond to remote controls or wall switches. It has a safety feature that shuts down the fireplace after 9 hours of continuous operation in this position.

REMOTE Position: This allows operation from the IntelliFire app or various remote controls. The unit will also automatically shut down after 9 hours of continuous operation without a command in this position.


How do I manually shut off the MONESSEN AVFL42NIF-BU if the remote or wall switch malfunctions?

If the standard controls fail to turn off the MONESSEN AVFL42NIF-BU, you can use these manual methods:

Unplug the appliance from the electrical source.

Locate the house circuit breaker for the appliance and turn it off.

Turn the reset switch, located on the front face of the unit (after removing the screen), to the OFF position.


What are the required maintenance tasks and frequencies for the MONESSEN AVFL42NIF-BU?

The following maintenance schedule should be followed for the MONESSEN AVFL42NIF-BU:

Task Frequency To be completed by
Surrounds Annually Homeowner
Remote Control Seasonally Homeowner
Pilot Inspection and Cleaning Annually Qualified Service Technician
Log/Crushed Glass Media Inspection Annually Qualified Service Technician
Firebox Inspection Annually Qualified Service Technician
Control Compartment and Firebox Top Annually Qualified Service Technician
Burner Ignition and Operation Annually Qualified Service Technician

What should I do if my MONESSEN AVFL42NIF-BU releases an odor or makes metallic noises?

Odor from appliance: This is common during the first several hours of operation due to manufacturing oils burning off. Odors can also be caused by dust or pet dander collecting on the burner. Have a technician clean the appliance before the start of each season.

Metallic noise: No action is necessary. This is caused by metal expansion and contraction as the unit heats up and cools down, similar to a furnace duct. It does not affect operation or longevity.


What do the LED error codes on the MONESSEN AVFL42NIF-BU IFT2-ECM indicate?

The LED indicator on the control module will blink codes to identify specific issues:

LED Error Code Description
2 Red: 1 Green Pilot valve solenoid not detected or open pilot flame coil.
2 Red: 2 Green Ignition feedback signal error, spark coil failure, or low-impedance short.
3 Red: 1 Green Appliance Safely Disabled; pilot sparks for 90 seconds with no flame rectification.
4 Red: 1 Green 110VAC power is connected to the wall switch.
6 Red: 1 Green Error ODS. Move On/Off/Remote switch to OFF for 3 seconds to clear.
7 Red: 1 Green Error Power Vent. Move On/Off/Remote switch to OFF for 3 seconds to clear.
8 Red: 1 Green ECM error.