MARTIN ROBOSCAN 805 (01) Image

Free English MARTIN ROBOSCAN 805 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD MARTIN ROBOSCAN 805 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the features of the MARTIN ROBOSCAN 805?

The MARTIN ROBOSCAN 805 is a high-performance, intelligent spotlight which features:

• High quality stepper motors

• 4 dichroic colors, plus white

• The MARTIN ROBOSCAN 805 has motorized gobos featuring 5 different patterns.

• Precision optics

• Adjustable focus

• 180 degree pan and 90 degree tilt

• 150 watt halogen lamp

• Efficient fan cooling

• Can be controlled by Martin 2501 (32 pcs.), 2308 (8 pcs.), 2032 (32 pcs.), 3032 (96 pcs.)

• Can be controlled by DMX 512 via Martin Interface.

• Can run without controller using built-in random-sequence programmes with and without music trig. (Stand alone)

• Built-in microphone for music triggering.

• Built-in variable speed control.


How do I install the MARTIN ROBOSCAN 805?

To install the MARTIN ROBOSCAN 805, please follow these steps:

1. Before opening the MARTIN ROBOSCAN 805, be sure to position the mirror correctly to avoid damage.

2. Remove the 4 knurled screws and pull out the chassis. The lamp can now be installed.

3. Check the mains voltage on the power supply board:

• USA/Canada: 110 / 115 / 120V – 60 Hz.

• Europe: 220 / 230 / 240V – 50 Hz.

4. If the lamp-life is shorter than expected, you can set the voltage to a higher value. This reduces the voltage applied to the lamp.

5. Push the MARTIN ROBOSCAN 805 chassis back into place and tighten the screws.

6. Mount the MARTIN ROBOSCAN 805, without fully tightening the clamps.

7. Remove the transport fixture from the mirror.


How do I operate the MARTIN ROBOSCAN 805 with a controller?

To connect the MARTIN ROBOSCAN 805 to a controller, follow these steps for the serial transmission link:

• Connect the MARTIN ROBOSCAN 805, or the first unit in the link, to the controller, using the 10 metre XLR/XLR or XLR/Dsub cable which came with the controller.

• The cable supplied with the RoboScan is used to interconnect the units in the link. A standard balanced microphone cable can be used as an extension if necessary.

• The units should be connected together in an order which gives the minimum cable length. This order has no influence on the address as far as the controller is concerned.

• The termination plug which came with the controller is plugged into the unused XLR socket on the last unit on the link.

CAUTION: THE CONTROLLER MUST NOT BE SWITCHED ON UNTIL 2 MINUTES AFTER THE UNITS HAVE BEEN SWITCHED ON.


How do I set the operating address for each MARTIN ROBOSCAN 805?

Set the DIP switch to the address number you want each MARTIN ROBOSCAN 805 to use. Please refer to the Address Settings Table for the correct DIP switch settings.


How do I operate the MARTIN ROBOSCAN 805 without a controller in stand-alone mode?

When operating the MARTIN ROBOSCAN 805 without a controller, you have a choice of programmes. Please refer to the Sequence Settings Table to select a programme using the DIP switches.


What are the DIP switch address settings for the MARTIN ROBOSCAN 805?

The following table shows the address settings for the MARTIN ROBOSCAN 805. The settings refer to the pin(s) on the DIP switch which are set to the ON position. For example, for Unit no. 7, pins 1, 2, and 3 are set to the ON position.

Unit no. Pins ON Unit no. Pins ON
1 1 17 1,5
2 2 18 2,5
3 1,2 19 1,2,5
4 3 20 3,5
5 1,3 21 1,3,5
6 2,3 22 2,3,5
7 1,2,3 23 1,2,3,5
8 4 24 4,5
9 1,4 25 1,4,5
10 2,4 26 2,4,5
11 1,2,4 27 1,2,4,5
12 3,4 28 3,4,5
13 1,3,4 29 1,3,4,5
14 2,3,4 30 2,3,4,5
15 1,2,3,4 31 1,2,3,4,5
16 5 32 6

What are the stand-alone sequence settings for the MARTIN ROBOSCAN 805?

The following table shows the sequence settings for operating the MARTIN ROBOSCAN 805 without a controller (stand-alone). The settings refer to the pin(s) on the DIP switch which are set to the ON position. For example, for “Demo 1”, pins 2 and 6 are set to the ON position.

Description Pins ON
Test All switches set to OFF position
Demo 1 2,6
Demo 1, with music trig 1,2,6
Demo 2 3,6
Demo 2, with music trig 1,3,6
Demo Random wide angle 2,3,6
Demo Random wide angle, with music trig 1,2,3,6
Demo Random narrow angle 4,6
Demo Random narrow angle, with music trig 1,4,6
Mechanical stop (For service use) 1,3,4,5,6
Adjustment (For service use) 3,4,5,6
Led chase (For service use) 2,4,5,6

What are the technical specifications for the MARTIN ROBOSCAN 805?

Dimensions :
Length 560 mm
Width 130 mm
Height 110 mm
Weight: 8.0 Kg
Power consumption: 180 W
Lamp: 150 W HLX

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD MARTIN ROBOSCAN 805 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.