What are the features of the MARTIN ROBOSCAN 804?
The MARTIN ROBOSCAN 804 is a high-performance, intelligent spotlight which features:
• High quality stepper motors
• 4 dichroic colors, plus white
• 8 manually selectable gobos
• Precision optics
• Adjustable focus
• 180 degree pan and 90 degree tilt
• 150 watt halogen lamp
• Efficient fan cooling
• Can be controlled by Martin 2501 (32 pcs.), 2308 (8 pcs.), 2032 (32 pcs.), 3032 (96 pcs.)
• Can be controlled by DMX 512 via Martin Interface.
• Can run without controller using built-in random-sequence programmes with and without music trig. (Stand alone)
• Built-in microphone for music triggering.
• Built-in variable speed control.
How do I install the MARTIN ROBOSCAN 804?
To install the MARTIN ROBOSCAN 804, follow these steps:
1. Before opening the unit, be sure to position the mirror as shown in figure 1 of the user guide. Failure to do this can result in damage to the mirror.
2. Remove the 4 knurled screws as shown in figure 2 of the user guide and pull out the chassis as shown in figure 3. The lamp can now be installed. On the MARTIN ROBOSCAN 804, the desired gobo can be selected by turning the gobo wheel.
3. Check the mains voltage on the power supply board. The correct settings are:
• USA/Canada: 110 / 115 / 120V – 60 Hz.
• Europe: 220 / 230 / 240V – 50 Hz.
4. If the lamp-life is shorter than expected, you can set the voltage to a higher value. This reduces the voltage applied to the lamp.
5. Push the chassis back into place and tighten the screws.
6. Mount the MARTIN ROBOSCAN 804, without fully tightening the clamps.
7. Remove the transport fixture from the mirror.
How do I connect the MARTIN ROBOSCAN 804 to a controller?
To connect the serial transmission link for operating with a controller, follow these steps:
• Connect the MARTIN ROBOSCAN 804, or the first unit in the link, to the controller, using the 10 metre XLR/XLR or XLR/Dsub cable which came with the controller.
• The cable supplied with the RoboScan is used to interconnect the units in the link. A standard balanced microphone cable can be used as an extension if necessary.
• The units should be connected together in an order which gives the minimum cable length. This order has no influence on the address as far as the controller is concerned.
• The termination plug which came with the controller is plugged into the unused XLR socket on the last unit on the link.
How do I set the operating address for the MARTIN ROBOSCAN 804?
Set the DIP switch to the address number you want each MARTIN ROBOSCAN 804 to use. Please refer to the Address Settings Table.
CAUTION: THE CONTROLLER MUST NOT BE SWITCHED ON UNTIL 2 MINUTES AFTER THE UNITS HAVE BEEN SWITCHED ON.
How do I operate the MARTIN ROBOSCAN 804 without a controller (stand-alone mode)?
When operating the MARTIN ROBOSCAN 804 without a controller, you have a choice of programmes. Please refer to the Sequence Settings Table for the available options.
What are the DIP switch address settings for the MARTIN ROBOSCAN 804?
The DIP switch address settings refer to the pin(s) on the DIP switch which are set to the ON position. For example, for Unit no. 1, only pin “1” is ON. For Unit no. 3, pins “1,2” are ON.
| Address settings for the Roboscan 804/805 | |||
|---|---|---|---|
| Unit no. | Pins ON | Unit no. | Pins ON |
| 1 | 1 | 17 | 1,5 |
| 2 | 2 | 18 | 2,5 |
| 3 | 1,2 | 19 | 1,2,5 |
| 4 | 3 | 20 | 3,5 |
| 5 | 1,3 | 21 | 1,3,5 |
| 6 | 2,3 | 22 | 2,3,5 |
| 7 | 1,2,3 | 23 | 1,2,3,5 |
| 8 | 4 | 24 | 4,5 |
| 9 | 1,4 | 25 | 1,4,5 |
| 10 | 2,4 | 26 | 2,4,5 |
| 11 | 1,2,4 | 27 | 1,2,4,5 |
| 12 | 3,4 | 28 | 3,4,5 |
| 13 | 1,3,4 | 29 | 1,3,4,5 |
| 14 | 2,3,4 | 30 | 2,3,4,5 |
| 15 | 1,2,3,4 | 31 | 1,2,3,4,5 |
| 16 | 5 | 32 | 6 |
What are the stand-alone sequence settings for the MARTIN ROBOSCAN 804?
The sequence settings refer to the pin(s) on the DIP switch which are set to the ON position. For example, for Demo 1, pins “2,6” are set to the ON position.
| Sequence settings for the Roboscan 804/805 | |
|---|---|
| Description | Pins ON |
| Test | All switches set to OFF position |
| Demo 1 | 2,6 |
| Demo 1, with music trig | 1,2,6 |
| Demo 2 | 3,6 |
| Demo 2, with music trig | 1,3,6 |
| Demo Random wide angle | 2,3,6 |
| Demo Random wide angle, with music trig | 1,2,3,6 |
| Demo Random narrow angle | 4,6 |
| Demo Random narrow angle, with music trig | 1,4,6 |
| Mechanical stop (For service use) | 1,3,4,5,6 |
| Adjustment (For service use) | 3,4,5,6 |
| Led chase (For service use) | 2,4,5,6 |
What are the technical specifications for the MARTIN ROBOSCAN 804?
| Roboscan 804/805 | |
|---|---|
| Dimensions : | |
| Length | 560 mm |
| Width | 130 mm |
| Height | 110 mm |
| Weight: | 8.0 Kg |
| Power consumption: | 180 W |
| Lamp: | 150 W HLX |