What are the general safety warnings for the LOVATO ELECTRIC EXP10 12T?

Please adhere to the following safety warnings when handling the LOVATO ELECTRIC EXP10 12T:

• Carefully read the manual before the installation or use.

• The product must be installed by qualified personnel, complying to current standards, to avoid damages or safety hazards.

• Before any intervention on the device, remove all the voltages from measuring and supply inputs and short-circuit the CT secondary windings.

• The manufacturer cannot be held responsible for electrical safety in case of improper use of the equipment.

• The products described in our documentation are subject to revision for modification or improvement. We disclaim any responsibility for consequences arising from them are accepted.

• A circuit breaker must be included in the electrical installation of the building. It must be installed close to the equipment and within easy reach of the operator. It must be marked as the disconnecting device of the equipment: IEC/EN 61010-1 § 6.11.3.1.

• Clean the instrument with a soft dry cloth; do not use abrasives, liquid detergents or solvents.


What is the function of the LOVATO ELECTRIC EXP10 12T expansion module?

The LOVATO ELECTRIC EXP10 12T is an expansion module designed to enhance the functions of connectivity, I/O, memory, and analysis of the device to which it is connected. Specifically, it implements the opto-isolated RS485 serial interface. This module can be connected to a LOVATO Electric device equipped with an EXP slot. The connection is made by plugging it into the expansion slot of the base device, which will automatically recognize it. The EXP parameters are set up directly from the base device menu.


What are the main features of the LOVATO ELECTRIC EXP10 12T?

The main features of the LOVATO ELECTRIC EXP10 12T are:

• Compact size.

• Direct plug-in on the base device.

• RS485 communication interface, isolated (4kVrms for 1 minute with base device).

• The EXP1012T version comes with a tropicalized PCB.


Which products are compatible with the LOVATO ELECTRIC EXP10 12T?

The LOVATO ELECTRIC EXP10 12T can be connected to a LOVATO Electric product fitted with an EXP… receptacle slot. Verify the compatibility for products with the following table:

Base device Base device firmware Rev.
DMG6… ≥ 00
DMG700 ≥ 00
DMG800 ≥ 00
DMG900…/DMG900T… ≥ 00
RGK800/900… – RGK800/900 SA – RGK900 MC ≥ 00
PMVF30… ≥ 00
PMVF20… ≥ 00
DCRG8 ≥ 00
DCRL3/DCRL5/DCRL8 ≥ 00
ATL610/ATL800/ATL900 ≥ 00
FFL800… (for EXP10 12T model) ≥ 00

Are there any special instructions for installing the LOVATO ELECTRIC EXP10 12T on a DMG series multimeter?

Yes. When the EXP… module is installed on a DMG series multimeter, it is mandatory to install the sealable terminal block covers supplied with the multimeter.


How do I install the LOVATO ELECTRIC EXP10 12T?

Follow these steps to connect the module:

1. Remove any dangerous voltage.

2. Remove terminal covers and terminal block.

3. Remove the expansion slot cover where the module will be plugged in.

4. Insert the expansion as illustrated in the manual.

5. Replace the terminal block and the terminal cover.

6. Power up the system (the base device will automatically recognise the expansion unit).


How do I remove the LOVATO ELECTRIC EXP10 12T?

To remove the module, first remove any dangerous voltage and repeat the operations from step 5 to step 2 of the installation procedure in reverse order. Press in the point indicated by the arrow symbol in the manual in order to remove the module.


How do I set up the parameters for the LOVATO ELECTRIC EXP10 12T?

For the EXP parameters configuration, see the manual of the base instrument to which it intends to connect.


What are the technical specifications for the LOVATO ELECTRIC EXP10 12T?

Supply
Supply voltage 5V= (supplied by base device)
Current consumption 50mA
Power consumption/dissipation 0.25W
RS485 port connection
Connection Plug in/Removable terminals
Number of terminals 4
Conductor cross section (min-max) 0.2-1.5 mm² (28-14 AWG)
Tightening torque 0.18 Nm (1.7 lbin)
Base device connection
Type of connector Plug-in
Insulation
Rated impulse withstand voltage Uimp 7.3kV
Power frequency withstand voltage 4kV
Ambient conditions
Operating temperature -20 to +60°C
Storage temperature -30 to +80°C
Relative humidity <80% (IEC/EN 60068-2-70)
Maximum pollution degree 2
Overvoltage category 3
Altitude ≤2000m
Climatic sequence Z/ABDM (IEC/EN 60068-2-61)
Shock resistance 15g (IEC/EN 60068-2-27)
Vibration resistance 0.7g (IEC/EN 60068-2-6)
Housing
Mounting Plug in on device expansion slot
Material Polyamide RAL7035
Degree of protection IP20
Weight 50g
Certifications and compliance
Certifications obtained EAC, cULus (only for EXP10 12)
UL Marking RS485 output
Use 60°C/75°C copper (CU) conductor only
AWG Range: 28 – 14 AWG stranded or solid
Field Wiring Terminals Tightening Torque: 1.7lb.in
Comply with standards IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL508, CSA C22.2 n°14

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD LOVATO ELECTRIC EXP10 12T (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.