What are the key safety warnings for the LOVATO ELECTRIC EXP10 12?
Carefully read the manual before the installation or use of the LOVATO ELECTRIC EXP10 12. Key safety points include:
• This equipment is to be installed by qualified personnel, complying to current standards, to avoid damages or safety hazards.
• Before any maintenance operation on the device, remove all the voltages from measuring and supply inputs and short-circuit the CT input terminals.
• A circuit breaker must be included in the electrical installation of the building. It must be installed close by the equipment and within easy reach of the operator. It must be marked as the disconnecting device of the equipment: IEC/EN 61010-1 § 6.11.3.1.
How should I clean the LOVATO ELECTRIC EXP10 12?
Clean the LOVATO ELECTRIC EXP10 12 with a soft dry cloth; do not use abrasives, liquid detergents or solvents.
What are the main features of the LOVATO ELECTRIC EXP10 12 expansion module?
The LOVATO ELECTRIC EXP10 12 is an expansion module that implements the opto-isolated RS485 serial interface. Its key features are:
• Compact size
• Direct plug in on the base device
• RS485 communication interface, isolated (4kVrms for 1 minute with base device)
• The EXP1012T model is a version with a tropicalized PCB
Which LOVATO Electric devices are compatible with the LOVATO ELECTRIC EXP10 12?
The LOVATO ELECTRIC EXP10 12 can be connected to a LOVATO Electric product fitted with an EXP… receptacle slot. Verify compatibility using the following table:
| EXP10 12 Compatibility | |
|---|---|
| Base device | Base device firmware Rev. |
| DMG6… | ≥ 00 |
| DMG700… | ≥ 00 |
| DMG800… | ≥ 00 |
| DMG900… / DMG900T… | ≥ 00 |
| RGK800/900… – RGK800/900 SA – RGK900 MC | ≥ 00 |
| PMVF30… | ≥ 00 |
| PMVF20… | ≥ 00 |
| DCRG8 | ≥ 00 |
| DCRL3 / DCRL5 / DCRL8 | ≥ 00 |
| ATL610 / ATL800 / ATL900 | ≥ 00 |
For the tropicalized EXP10 12T model:
| EXP10 12T Compatibility | |
|---|---|
| Base device | Base device firmware Rev. |
| FFL800… | ≥ 00 |
Are there any special instructions when installing the LOVATO ELECTRIC EXP10 12 on a DMG series multimeter?
Yes. When the LOVATO ELECTRIC EXP10 12 module is installed on a DMG series multimeter, it is mandatory to install the sealable terminal block covers supplied with the multimeter.
What is the procedure for connecting the LOVATO ELECTRIC EXP10 12 module?
Follow these steps to connect the LOVATO ELECTRIC EXP10 12:
1. Remove any dangerous voltage.
2. Remove terminal covers and the terminal block.
3. Remove the expansion slot cover where the module will be plugged in.
4. Insert the expansion module as illustrated in the user manual.
5. Replace the terminal block and the terminal cover.
6. Power up the system. The base device will automatically recognise the expansion unit.
How do I remove the LOVATO ELECTRIC EXP10 12 module?
To remove the LOVATO ELECTRIC EXP10 12, first remove any dangerous voltage. Then, repeat the installation steps from 5 to 2 in reverse order. Press in the indicated point on the module to release and remove it.
How are the parameters for the LOVATO ELECTRIC EXP10 12 configured?
The parameter setup for the LOVATO ELECTRIC EXP10 12 is done directly from the base device menu. For the configuration of the EXP parameters, see the manual of the base instrument to which it is connected.
What are the technical characteristics of the LOVATO ELECTRIC EXP10 12?
| Supply | |
| Supply voltage | 5V DC (supplied by base device) |
| Current consumption | 50mA |
| Power consumption/dissipation | 0.25W |
| RS485 port connection | |
| Connection | Plug in/Removable terminals |
| Number of terminals | 4 |
| Conductor cross section (min-max) | 0.2-1.5 mm² (28-14 AWG) |
| Tightening torque | 0.18 Nm (1.7 lbin) |
| Base device connection | |
| Type of connector | Plug-in |
| Insulation | |
| Rated impulse withstand voltage Uimp | 7.3kV |
| Power frequency withstand voltage | 4kV |
| Ambient conditions | |
| Operating temperature | -20 to +60°C |
| Storage temperature | -30 to +80°C |
| Relative humidity | <80% (IEC/EN 60068-2-70) |
| Maximum pollution degree | 2 |
| Overvoltage category | 3 |
| Altitude | ≤2000m |
| Climatic sequence | Z/ABDM (IEC/EN 60068-2-61) |
| Shock resistance | 15g (IEC/EN 60068-2-27) |
| Vibration resistance | 0.7g (IEC/EN 60068-2-6) |
| Housing | |
| Mounting | Plug in on device expansion slot |
| Material | Polyamide RAL 7035 |
| Degree of protection | IP20 |
| Weight | 50g |
| Certifications and compliance | |
| Certifications obtained | EAC, cULus (only for EXP10 12) |
| UL Marking | RS485 output Use 60°C/75°C copper (CU) conductor only AWG Range: 28 – 14 AWG stranded or solid Field Wiring Terminals Tightening Torque: 1.7lb.in |
| Comply with standards | IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL508, CSA C22.2 n°14 |
What are the mechanical dimensions of the LOVATO ELECTRIC EXP10 12?
The mechanical dimensions of the LOVATO ELECTRIC EXP10 12 are as follows:
• Width: 22.0 mm
• Height: 46.8 mm
• Total Depth: 64.5 mm
• Depth (from front plate): 38.2 mm