FREE ENGLISH LIEBHERR HCB 1561 (01) PDF DOCUMENT.
FREE ENGLISH LIEBHERR HCB 1561 (01) PDF USER GUIDE.
FREE ENGLISH LIEBHERR HCB 1561 (01) PDF USER MANUAL.
FREE ENGLISH LIEBHERR HCB 1561 (01) PDF OWNER GUIDE.
FREE ENGLISH LIEBHERR HCB 1561 (01) PDF OWNER MANUAL.
FREE ENGLISH LIEBHERR HCB 1561 (01) PDF REFERENCE GUIDE.
FREE ENGLISH LIEBHERR HCB 1561 (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH LIEBHERR HCB 1561 (01) PDF REFERENCE MANUAL.
FREE ENGLISH LIEBHERR HCB 1561 (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH LIEBHERR HCB 1561 (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD LIEBHERR HCB 1561 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What do the safety statements in the LIEBHERR HCB 1561 installation manual mean?
The manual for the LIEBHERR HCB 1561 uses the following safety statements:
WARNING: This indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: This indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
IMPORTANT: This highlights information that is especially relevant for a problem-free installation.
What are the general safety precautions for installing the LIEBHERR HCB 1561?
When installing the LIEBHERR HCB 1561, you should always wear protective devices such as protective gloves and eye shields. It is also recommended to use hearing protection when drilling holes into concrete floors.
What are the electrical requirements and safety warnings for the LIEBHERR HCB 1561?
Electrical Supply:
A 115 Volt, 60 Hz, 15 Amp fused electrical supply is required. It is recommended to use a dedicated circuit for the appliance to prevent electrical overload. Ensure the incoming voltage is the same as the unit rating.
Installation and Wiring:
To reduce the risk of fire, electric shock, or personal injury, all installation work and electrical wiring must be performed by a qualified electrician in accordance with all applicable codes and standards, including fire-rated construction.
ELECTROCUTION HAZARD:
The appliance is equipped with a three-prong (grounding) polarized plug for protection against shock hazards.
• Do not remove the round grounding prong from the plug.
• Do not use a two-prong grounding adapter.
• Do not use an extension cord to connect power to the unit.
GROUNDING WARNING:
Do not ground the appliance to a gas pipe. If you are not sure if the appliance is properly grounded, have it checked by a qualified electrician. There should not be a fuse in the neutral or grounding circuit.
What are the area and floor requirements for installing the LIEBHERR HCB 1561?
Before installing the LIEBHERR HCB 1561, verify the following area requirements:
• The floors must be able to support the appliance’s weight plus approximately 1200 pounds (544 kg) of food weight.
• The finished kitchen floor must be level. If the floor is not level, the appliance must be shimmed to ensure the air vents are not obstructed.
• Remove anything attached to the rear or side walls that could obstruct the appliance opening.
• Ensure the cabinet cutout dimensions are accurate and the electrical outlet is in the correct location.
What should be done before turning on the LIEBHERR HCB 1561 for the first time after installation?
To protect the LIEBHERR HCB 1561 from possible damage, allow the appliance to stand for 1/2 to 1 hour in place after installation before turning the electricity on. This waiting period allows the refrigerant and system lubrication to reach equilibrium.
Can the LIEBHERR HCB 1561 be installed directly next to another refrigerator or freezer?
No. You should not install the LIEBHERR HCB 1561 next to any other refrigerator or freezer. Doing so can cause condensation or damage to the appliance.
What are the ventilation requirements for the LIEBHERR HCB 1561?
The LIEBHERR HCB 1561 does not require any ventilation openings in the cabinet itself. The necessary air flow is directed through the toe kick area at the bottom of the unit.
It is crucial to use only the ventilation grille provided with the appliance, as it is required for proper operation. The air flow must not be restricted. The toe kick opening must not be covered with a cabinet base. Failure to use the supplied grille can lead to product failure and will void the warranty.
What are the unit dimensions of the LIEBHERR HCB 1561?
The dimensions for the LIEBHERR HCB 1561 are as follows:
| Part | Dimension |
|---|---|
| A (Toe Kick Height) | 3″ (76 mm) |
| B (Overall Height) | 79-13/16″ (2027 mm) |
| C (Overall Width) | 29-7/8″ (757 mm) |
| D (Overall Depth) | 24″ (610 mm) |
| E (Door Swing) | 55 1/4″ (1413 mm) |
| F (Lower Section Height) | 37-1/8″ (952 mm) |
How much door swing clearance is needed for the LIEBHERR HCB 1561?
When installing the LIEBHERR HCB 1561 next to a wall, you must allow for a door swing clearance of at least 12-1/2 inches (317 mm). This measurement is for the appliance door only, without any custom front panels mounted. Be sure to add your panel thickness and handle depth to this measurement to avoid any interferences.
What are the required cabinet opening dimensions for the LIEBHERR HCB 1561?
The required cabinet opening dimensions for the LIEBHERR HCB 1561 depend on the cabinet style:
| Cabinet Height (C) | Inset Cabinet Depth (B) | Frameless/Faceframe Cabinet Depth (B) |
|---|---|---|
| 80″ | 24″ + panel thickness | 24″ |
| 84″ | 24″ + panel thickness | 24″ |
For an installation where the appliance panel is to be flush with surrounding cabinetry, the depth of the adjacent cabinets must be equal to the appliance depth (24″) plus the thickness of your custom panel (typically 5/8″ to 3/4″).
Where should the electrical outlet and water supply line be placed for the LIEBHERR HCB 1561?
Electrical Outlet: The outlet can be located within an 80-inch radius from the top center of the appliance. IMPORTANT: Do not install the electrical outlet directly behind the appliance.
Water Supply Line: For the HCB 1561 model, the water line can be fed in from the left or right, positioned above the anti-tipping bracket. The lead-through opening for the water line is at the bottom right of the appliance. IMPORTANT: Do not install the water shut-off valve behind the appliance.
What are the requirements for custom panels for the LIEBHERR HCB 1561?
Thickness: Custom panels should have a minimum thickness of 5/8 inch (16 mm) and a maximum thickness of 3/4 inch (19 mm).
Weight: The weight of the custom refrigerator door panel must not exceed 60 lbs (27 kg).
Dimensions: Panel dimensions vary based on the installation style (Inset or Frameless) and the cabinet opening height (80″ or 84″).
Inset Installation Style Panel Dimensions:
| Cabinet Opening Height | Refrigerator Door Panel Height |
|---|---|
| 80″ (2032 mm) | 45-1/4″ (1150 mm) |
| 84″ (2134 mm) | 49-1/4″ (1251 mm) |
The freezer drawer panels for an inset style should both be 29-3/4″ (755 mm) wide.
Frameless Installation Style Panel Dimensions:
| Cabinet Opening Height | Refrigerator Door Panel Height |
|---|---|
| 80″ (2032 mm) | 45-3/4″ (1162 mm) |
| 84″ (2134 mm) | 49-3/4″ (1264 mm) |
The freezer drawer panels for a frameless style should both be 30-7/16″ (773 mm) wide.
How do I install the anti-tipping device for the LIEBHERR HCB 1561?
The anti-tipping bracket is essential to prevent the appliance from tipping forward when the fully stocked door is opened.
WARNING: Be sure that there is no plumbing or electrical wiring in the installation area that could be damaged by screws or drills.
1. On the back wall of the opening, mark the center line of the appliance.
2. Align the center of the anti-tipping bracket with this marked line.
3. The bracket must be fitted at the same height as the appliance’s toe kick area. If you are raising the appliance on spacers, the bracket must be raised to the same height.
4. Depending on your floor and wall material, choose the appropriate mounting option:
• Wooden Floors: Use screws (6 x 63 mm) to fasten the bracket to the floor.
• Concrete Walls: Use wall plugs and screws (6 x 63 mm) to fasten to the wall.
• Concrete Floors: Use the provided anchors to secure the bracket to the floor.
• Wall Plate: You can mount the bracket to a wall plate, turning the screws in at an angle.
What is required if installing the LIEBHERR HCB 1561 in a cabinet deeper than 25 inches?
If your cabinet depth is greater than 25 inches, you must install a wooden spacer between the back of the appliance and the wall. This ensures the anti-tipping bracket functions correctly.
WARNING: The wooden spacer must be fastened securely to the floor.
1. Determine the required thickness of the spacer by measuring the clearance between the appliance and the wall.
2. Securely fasten the wooden spacer to the floor at the rear of the cabinet opening.
3. Mount the anti-tipping bracket to the wooden spacer and/or wall as specified in the general installation instructions.
IMPORTANT: If the floor has a sideways slope, the anti-tipping bracket must be installed perfectly horizontally. Use spacers under the bracket as needed to achieve this.
How do I install the side cover strips on the LIEBHERR HCB 1561?
1. The cover strips are applied to the side walls of the appliance, covering the areas above, between, and below the securing plates.
2. Cut the cover strips to the lengths shown in the installation diagrams (Figure 14).
3. Fit the adhesive cover strips, making sure to leave a 1/4 inch gap to each securing plate. This ensures a problem-free fitting of the covers.
What are the water connection requirements for the icemaker on the LIEBHERR HCB 1561?
Professional Installation: The water connection must be performed by a trained and licensed plumber.
Water Pressure:
• With the supplied Liebherr water filter installed, the pressure must be between 40-90 psi (2.8-6.2 bar).
• Without the filter, the acceptable pressure range is 22-87 psi (1.5-6 bar).
Supply Line: Use a 1/4″ OD copper line (not supplied) for the connection.
Shut-off Valve: An accessible shut-off valve must be installed between the hose line and the main water supply. Do not install the shut-off valve behind the refrigeration unit.
Solenoid Valve: The valve has a metric R3/4 male connector. A R3/4 (metric) to 1/4″ OD adapter is supplied. You must insert the provided water strainer into the adapter with the cavity facing downwards before mounting it to the solenoid valve.
How do I connect the LIEBHERR HCB 1561 to the water supply?
WARNING: Do not connect the appliance to the electrical outlet before the installation is completed and the water line is connected to the solenoid valve.
1. Move the appliance toward its final position, but leave enough space to work behind it.
2. Insert the water supply line through its intended opening at the back of the appliance.
3. Slowly move the appliance into the recess until the back of the appliance slides into the anti-tipping bracket.
4. At the front of the appliance, in the toe kick area, remove the cover from the valve connector.
5. Connect the water line to the OD adapter.
6. Bleed the air from the water line by temporarily opening the water supply.
7. Screw the OD adapter onto the solenoid valve.
8. Fully open the shut-off valve and check the entire water system for any leaks.
IMPORTANT: After starting up the appliance, the water pipe system must be purged of any air. Refer to the “Bleeding the Ice Maker” chapter in the operating instructions for details.
How do I level the LIEBHERR HCB 1561?
1. Front Leveling: Adjust the height of the appliance at the front by twisting the leveling feet (labeled ①). Use the provided open-ended spanner. Turn the spanner counterclockwise to raise the appliance and clockwise to lower it.
2. Rear Leveling: Adjust the height at the rear by turning the adjusting bolts (labeled ②). Use a 1/4″ box spanner or the provided Torx 25 wrench.
3. Final Check: Rotate the front leveling feet until they are firmly in contact with the floor.
WARNING: To prevent the appliance from tipping forward, the leveling feet must have firm contact with the floor.
How do I fasten the LIEBHERR HCB 1561 into the cabinet recess?
1. Secure the appliance in the recess by fastening it through the premounted securing plates located on the left and right sides of the appliance housing.
2. Use screws (4 x 16 mm) for this purpose.
3. After fastening, click the supplied covers into place over the screws and plates.
How can I adjust the refrigerator door on the LIEBHERR HCB 1561?
IMPORTANT: Under normal conditions, the factory adjustment of the refrigerator door should not be changed. This adjustment should only be made if you expect to have heavy loading on the door.
To adjust the lateral tilt of the door:
1. Loosen the screws (labeled ①) on the door hinge.
2. Use an Allen key (A/F 2.5) to turn the grub screw (labeled ②) to make the adjustment.
How do I adjust the freezer drawer fronts on the LIEBHERR HCB 1561?
If required, the front of the freezer drawers can be adjusted for alignment.
1. On the left and right sides of the freezer drawer, transfer the mounting screws individually to the long adjustment slots located below the standard holes.
2. Once the drawer front is in the correct position, tighten the screws firmly.
How do I mount the ventilation grille on the LIEBHERR HCB 1561?
1. Pull out the bottom freezer drawer to access the toe kick area.
2. Remove the blue protective film from the supplied dust filter and insert the filter into its opening in the toe kick area. Engage the filter at the bottom, press down the button, and click it into place.
3. Take the two grille supports from the accessory pack and remove the locking pins from them.
4. Insert the supports into the left and right sides of the motor compartment.
5. Adjust the supports so that their front edge is flush with the front of the ventilation grille.
6. Insert the locking pins to block the supports in place.
7. Install the ventilation grille. The bolts on the inside of the grille must be inserted into the holes of the supports.
8. To adjust the height of the grille, loosen the grub screws at the front (using an Allen key A/F 2.5), set the grille to the desired height, and then tighten the grub screws.
What should be done before mounting custom door panels on the LIEBHERR HCB 1561?
Before you begin mounting your custom panels, you need to remove the attachment hardware from the appliance doors.
• Refrigerator Door: Remove the cover (labeled ①) and unscrew the upper and lower attachment brackets (labeled ②). These brackets will be mounted onto your custom refrigerator panel. IMPORTANT: Keep the nuts, as they are needed to fit the premounted panel onto the refrigerator door.
• Freezer Drawers: Unscrew the attachment brackets from both freezer drawers. These will be mounted onto your custom freezer panels. IMPORTANT: Keep the screws, as they are needed to fit the premounted panels onto the freezer drawers.
How do I mount the attachment brackets onto the custom door panels for the LIEBHERR HCB 1561?
1. On the back of your custom refrigerator door panel, mark a horizontal line at 41″ (1041 mm) from the bottom edge and another line at 4-1/4″ (107.5 mm) from the bottom edge.
2. Take one of the brackets you removed from the refrigerator door and align it to the 41″ line. Fasten the bracket with a minimum of 6 screws (4 x 16 mm), using any of the available holes in the bracket.
3. Align the second refrigerator door bracket to the 4-1/4″ line and fasten it in the same manner.
4. Fasten the brackets you removed from the freezer drawers onto your custom freezer drawer panels. Use three screws (4 x 16 mm) for each bracket. When positioning the bracket, ensure there is a 1/8″ (3 mm) gap at the bottom edge of the panel as shown in the diagram (Figure 34c).
How do I mount the custom refrigerator door panel onto the LIEBHERR HCB 1561?
1. Turn in the adjusting bolts on the bottom of the refrigerator door as far as they will go.
2. Open the refrigerator door and hang the custom panel (with its attached brackets) onto the top adjusting bolts.
3. Screw on the hex nuts to the top adjusting bolts and finger-tighten them for now.
4. Close the door to check the panel’s height. To adjust vertically, loosen the hex nuts and turn the adjusting bolts.
5. Align the panel horizontally by sliding it along the elongated holes in the attachment bracket.
6. Once horizontally aligned, securely tighten the top hex nuts.
7. Turn the bottom adjusting bolts until they make firm contact with the lower attachment bracket.
8. Screw on the hex nuts for the bottom bolts and tighten them securely.
9. For final fine-tuning, you can loosen the three screws on the top and bottom attachment brackets, align the panel perfectly, and then retighten the screws.
10. Click the hinge cover (labeled ①) into place. Insert the provided cover strip (labeled ②) into the gap between the appliance door and the custom panel.
How do I mount the custom freezer drawer panels onto the LIEBHERR HCB 1561?
CAUTION: Do not overtighten the screws. Do not use a power driver.
1. Pull out the upper freezer drawer. Screw the custom panel (with its attached brackets) onto the drawer front using three 3.5 x 13 mm screws on both the left and right sides.
2. Close the drawer and check its position relative to the surrounding cabinets. If needed, align the panel vertically by loosening the screws on both sides, adjusting the panel, and then retightening the screws.
3. Repeat the process for the lower freezer drawer and panel.
4. Finally, cover the gap between the two drawer panels using the supplied adhesive strips. Remove the protective foil from the strip and stick it on the top edge of the lower appliance drawer, making sure the flexible gasket is fully inserted into the gap.
CLICK HERE TO DOWNLOAD LIEBHERR HCB 1561 (01) PDF DOCUMENT