What should I do upon receiving the photometric probe?
Remove the photometric probe from the packing and examine it carefully. For further assistance, please contact your local Hanna Instruments Office or email us at tech@hannainst.com.
Each HI900600 series photometric probe is delivered in a plastic case and is supplied with:
• Trimmer tool
• Quality certificate
• Instruction manual
Note: Save all packing material until you are sure that the probe works correctly. Return items must be returned in the original packing material with the supplied accessories. Items that need to be returned must be returned in their original packing material with the supplied accessories.
What is the HI900600 series photometric probe and its intended use?
The HI900600 series are photometric probes used with a potentiometric titration for equivalence end point detection of colorimetric reactions. These probes are available in 4 different wavelengths from 470 nm to 625 nm and have a universal BNC connector that is used as a potentiometric input on Hanna titrators and autosamplers.
The optimal wavelength depends on the indicator for the method – a wavelength should be selected at which the indicator causes a large mV change between its reacted and unreacted forms.
What are the features of the HI900600 series photometric probes?
• Reflective measurement allows for high color sensitivity in a compact design.
• Drift from changes in temperature is automatically compensated.
• Glass body offers excellent chemical resistance.
• LED brightness trimmer is provided in the head of the probe to adjust the LED intensity.
What are the specifications of the HI900600 series photometric probes?
| mV range | 10 to 1100 mV |
| Light source | LED |
| Measuring cycle | LED pulsed at 1 kHz |
| Light detector | Silicon photocell |
| Sample temperature | 0 to 75 °C (32 to 167 °F) |
| Temperature drift | Less than 0.5 mV/°C |
| Body material | Glass |
| Body length / Overall length | 120 mm / 200 mm |
| Outer diameter | 12 mm |
| Connection | BNC with 1.5 meter cable for connecting to titrator or autosampler |
| Power supply | PS/2 connector for connecting to titrator |
| Environment | 0 to 50 °C (32 to 122 °F) |
What are the available models, their wavelengths, and LED colors?
| Code | Wavelength | LED Color |
| HI900601 | 525 nm | Green LED |
| HI900602 | 625 nm | Red LED |
| HI900603 | 590 nm | Yellow LED |
| HI900604 | 470 nm | Blue LED |
How do I install the HI900600 photometric probe?
• The HI900600 family of photometric probes can be connected to the HI932, HI931, HI902C, HI901C and HI901W titrators by plugging the BNC connector to the pH/ORP/ISE port and PS/2 connector to the keyboard port.
• For use with the HI921 and HI922 Autosamplers, install the electrode and dispensing tubes identical as the HI93x electrode holder. The cable of the electrode is long enough to reach the BNC and PS/2 connectors of the HI90x or HI93x Titrator.
• The dispensing tip must be slightly submerged into the sample during use, this prevents the titrant pump from injecting bubbles into the sample. If necessary trim the blue protective tubing to allow the dispensing tip to be submerged into the sample.
• The photometric probe can be installed in two locations on the HI93x electrode holder (one location on the HI90x). Both of these place the probe as far downstream from the clockwise-spinning titrant as possible.
What are the key details of the probe itself?
The probe features a Serial Number (on back), an LED Calibration Trimmer (covered), a Maximum Immersion Level, and an Optical Cell. The Recommended Immersion Level is 40 mm (1.5 in.). The overall length is 200 mm, with a body length of 120 mm and an outer diameter of Ø12 mm.
What are the general operational guidelines for using the photometric probe?
• To avoid the generation of air bubbles, the stir speed should not exceed 800 RPM.
• Reagent addition feature on the autosampler can generate air bubbles, it is recommended to add the reagents with the probe above the sample beaker. To do this set the head height to 80 to 100 mm for reagent addition operations.
• For best reproducibility, use linear dosing setting. If dynamic dosing is used a narrow range, such as 0.040 to 0.100 mL is recommended.
How do I perform LED calibration?
The LED will slowly dim over time, this is normal. LED adjustment is not critical for the measurement but it is recommended to follow this procedure before the first use and once per week.
• Connect the probe to the titrator or autosampler.
• Place the probe in deionized or distilled water. Swirl gently to remove any air bubbles from the optical cell.
• On the home screen or in mV mode, note the mV reading.
• Remove the cap covering the hole marked “CAL”.
• Using the supplied trimmer tool slowly turn the screw clockwise until the screen shows 1000 mV.
Caution: If the trimmer screw is turned too far in the positive (clockwise) direction, it is possible that the probe electronics can no longer amplify the mV signal. This will occur at some point above 1200 mV. If this occurs, it will take several turns of the screw in the negative (counter-clockwise) direction before a change in the mV signal will occur.
• Replace the cap when procedure is complete.
How should I care for and maintain the photometric probe?
The HI900600 photometric probes are fragile and can crack easily if mishandled. Handle the probe by the green top only and do not allow the stirrer assembly to hit it.
The probe can be cleaned after each use with a gentle stream of deionized or distilled water. If necessary, soak the probe in HI7061L Electrode cleaning solution for general use for 20 minutes, rinse thoroughly with distilled or deionized water before use.
What accessories are available for the photometric probe?
| Code | Description |
| HI900948 | Trimmer tool |
| HI900932 | PS/2 Y-splitter |
| HI7061L | Electrode cleaning solution for general use |
What are the recommendations for users of this product?
Before using this product, make sure it is entirely suitable for your specific application and for the environment in which it is used. Any variation introduced by the user to the supplied equipment may degrade the probe’s performance. For yours and the probe’s safety do not use (or store) it in hazardous environments.
CLICK HERE TO DOWNLOAD HANNA INSTRUMENTS HI900602 (01) PDF MANUAL