HANNA INSTRUMENTS HI7640-1805 (01) Image

FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF DOCUMENT.
FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF USER GUIDE.
FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF USER MANUAL.
FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF OWNER GUIDE.
FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF OWNER MANUAL.
FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF REFERENCE GUIDE.
FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF REFERENCE MANUAL.
FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH HANNA INSTRUMENTS HI7640-1805 (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD HANNA INSTRUMENTS HI7640-1805 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

How do I wire the probe to the controller?

1. Disconnect the controller from power. Run the probe cable through the conduit opening.

2. Connect the probe leads to the removable terminal connector marked PROBE. Follow lead markings (-/+) to ensure correct wiring position for output leads.

3. Carefully put the wired terminal connector into place on the board.

4. Position excess cable through the cable gland before tightening the nut.

5. Remove the ground screw and hardware located below the PROBE connector. Attach the ground lead.


What is the probe cabling color code?

Marking Attached Cable Patch Cable Functionality
GREEN BLACK 0 V
B WHITE WHITE RS485 D-
A YELLOW BLUE RS485 D+
+ BROWN RED 5 V
Ground Symbol GREEN-YELLOW GREEN-YELLOW PROTECTIVE GROUND

How do I connect the probe?

Align the pins and key then push the plug into the socket. Rotate the collar to lock in place.


What are the HI510 Controller supported probe series and configurations?

HI110 X X | Y 8 Z Z – pH & Temperature

XX Junction Type Y Glass Sensor Matching Pin pH range Temperature range
06 PTFE junction 1 Low temperature Titanium 0.00 to 12.00 pH -5.0 to 80.0 °C (23.0 to 176.0 °F)
16 Ceramic junction 3 High temperature 0.00 to 14.00 pH 0.0 to 100.0 °C (32.0 to 212.0 °F)
4 Fluoride resistant 0.00 to 10.00 pH -5.0 to 60.0 °C (23.0 to 140.0 °F)

HI20 X X | Y 8 Z Z – ORP & Temperature

XX Junction Type Y Sensor Type mV range Temperature range
04 PTFE junction 1 Platinum ± 2000 mV –5.0 to 100.0 °C (23.0 to 212.0 °F)
14 Ceramic junction 2 Gold

HI7630 – | Y 8 Z Z – Conductivity & Temperature

Y Cell Type Measurement Range
2 Two-electrode cell conductivity, AISI 316 stainless steel cell constant k ≈ 0.1/cm EC 0.000 µS/cm to 30.00 mS/cm
TDS 0.000 mg/L to 15.00 g/L (TDS factor 0.5)
RES 34 Ω•cm to 99.99 MΩ•cm
Temperature 0.0 to 50.0 °C (32.0 to 122.0 °F)
4 Four-ring conductivity, platinum on glass, cell constant k ≈ 1.0/cm EC 0.0 µS/cm to 999.9 mS/cm
TDS 0.0 mg/L to 400.0 g/L (TDS factor 0.5)
RES 1.00 Ω•cm to 9.99 MΩ•cm
Seawater Salinity 400.0 %NaCl, 42 psu, 80 ppt
Temperature 0.0 to 100.0 °C (32.0 to 212.0 °F)

HI7640 – 1 8 Z Z – Galvanic Dissolved Oxygen & Temperature

Galvanic sensor

Concentration 0.00 to 50.00 mg/L (ppm)
Saturation 0.0 to 500.0 %
Temperature –5.0 to 50.0 °C (23.0 to 122.0 °F)

HI7640 – 5 8 Z Z – Optical Dissolved Oxygen & Temperature

Optical sensor

Concentration 0.00 to 50.00 mg/L (ppm)
Saturation 0.0 to 500.0 %
Temperature –5.0 to 50.0 °C (23.0 to 122.0 °F)

ZZ Codes

8 Smart probe, with RS485 connection
ZZ

00 supplied with DIN connector (without cable)

05, 10, 15, 25, 50 fixed cable length (in meters)


CLICK HERE TO DOWNLOAD HANNA INSTRUMENTS HI7640-1805 (01) PDF DOCUMENT