HAIER DW-40L348 (01) PDF SUMMARY:
What models does this service manual apply to?
This service manual is effective for the DW-40L278, DW-40L348, and DW-40L508 deep freezer models.
What are the specifications of the deep freezers?
| Specification | DW-40L278 | DW-40L348 | DW-40L508 |
|---|---|---|---|
| External dimensions (mm) | 736x660x1810 | 750x840x1860 | 895x840x1860 |
| Internal dimensions (mm) | 520x435x1230 | 535x607x1228 | 685x650x1228 |
| Effective volume | 278L | 348L | 490L |
| Door | Foaming door | ||
| Foam material | Hard polyurethane | ||
| Compressor | Totally enclosed | ||
| Drawer | 6 | 12 | 10 |
| Refrigeration | Direct cooling | ||
| Outer/inner plate | Spraying steel/HIPS | ||
| Condenser/evaporator | Wire tube/plate | ||
| Temperature controller | Computer control | ||
| Refrigerant | R404a 215g | R404a 195g | R404a 245g |
| Weight | 115kg | 137kg | 164kg |
| Temperature range | -20°C ~ -40°C | -20°C ~ -40°C | -20°C ~ -40°C |
| Rated power supply | 220-240V/50Hz/60Hz | 220-240V/50Hz | 220-240V/50Hz |
| Rated power/current | 310W/3.1A | 360W/2.9A | 430W/2.91A |
| Noise level | 44dB(A) | 45dB(A) | 45dB(A) |
| Foaming agent | CP/IP | CP/IP | CP/IP |
| Climate type | 4 | 4 | 4 |
| Electrical protection | I | I | I |
| Power supply connection | Y | Y | Y |
| Testing hole | 1 | 1 | 1 |
| Alarm | Yes | ||
| Power outage alarm | 4-18 hours | ||
| Rechargeable battery | DC 12V |
Climate type 4 means the temperature is +30°C, and the relative humidity is 55%.
What are the regulations for type naming?
The rated volume can be the gross volume or effective volume, as decided by the manufacturer. The effective volume value must be marked on the nameplate whether effective volume or gross volume is marked in the product name.
What does “DW-40L348” mean?
DW-40L348 indicates a deep temperature storage refrigerator with a characteristic temperature of -40℃, horizontal orientation, and a rated effective volume of 348L.
What are the safety precautions to take note of?
- The machine uses AC 220-240V/50/60Hz power. If the voltage used is 10% higher or lower than the rated voltage, an auto stabilizer above 4000W should be equipped. Power lines that require lengthening should have a cross section no less than 1.5mm.
- An independent private jack should be used and reliably connected. The power line for the refrigerator is equipped with a three-wire, grounding-type plug which meets standard three-wire, grounding-type receptacle. In no circumstance should the third plug foot (grounding) of the power line be cut or removed. The plug should be touchable after installation. Power lines or plugs with abrasion should not be used. Abraded or damaged power lines should be sent to the maintenance point designated by the manufacturer or be replaced by qualified personnel.
- Hazardous articles of inflammable, explosive materials such as acid and alkali with strong corrosion are prohibited in the refrigerator.
- Flammable sprays should not be used close to the freezer to avoid fire.
- In the event of inflammable gas such as coal gas leakage:
- Shut the valve for leakage.
- Open the door and window for ventilation.
- Do not pull out or insert the power plug of the freezer.
- Prevent children from playing in the freezer to avoid accidents.
- Once the power of the freezer is cut, it should be re-connected at least five minutes later to avoid damage to the compressor or the system. The power should be cut for maintenance. Do not roll or damage the power line.
- Protective equipment should be worn when accessing the freezer to avoid freezing injury. When the freezer is scrapped, remove the doorman. The scrapped freezer should be kept away from fire and sent to an appointed site for disposition.
What are the components and function modules of the deep freezer?
- Temperature control: It is controlled by a microcomputer with a digital display for temperature, while the inner temperature can be adjusted from -20℃ to -40℃. There is parameter setting for super low temperature alarming and break down memory.
- Safety system:
- Alarm: high/low temperature alarm, sensor error alarm, power failure alarm, low battery alarm, high ambient temperature alarm, door opening alarm (only applicable to DW-40L278).
- Two alarming methods: sound buzzing alarming and red light alarming.
- Starting up delay protection function.
- Refrigerating system:
- Imported famous brand SECOP compressor is adopted.
- Environment protection free refrigerant.
- German famous brand EBM fan.
- High-density insulation layer with heat preservation.
- The evaporimeter is used as a rack directly for speed refrigeration.
- Humanity design:
- Drawer design for convenient utilization.
- LED digital temperature display for convenient observation.
- Broad voltage belt suitable for voltage.
- Doorknob design for easy on and off.
- Trundle design for convenient motion.
- Gate locks design for safe storage.
What should be paid attention to during the replacement of parts?
- The rivet nut should not be pulled too tightly.
- Omitting or lacking PS spacers.
- Forgetting spring washer.
What are the self-checking items after replacement?
- Whether the rivet nut is tight.
- Whether two PS spacers are used.
- Whether a spring washer is used.
How to disassemble the control board?
Unscrew the screws on the top side to fetch the control board. Note that there are wires connecting the control panel and the refrigerator. Installation should be the reverse of the disassembly steps.
What are the basic parameters of the computer board?
- Rated frequency: 50/60Hz
- Rated voltage: 220 -240 A.C
- Control current for press under normal operation should be no more than 10A
- The 5 minutes start delay for the first energization of press has change to 30S only in new machine. In normal operation, each time it is shut down, start timing, the compressor will not start if the start up time is less than 5 minutes; if the time is over 5 minutes, please take the actual time for operation.
What is the temperature display range?
The display range is from +50℃ to -60℃. Temperatures higher than +50℃ display as “50”, and temperatures lower than -60℃ display as “-60”.
How does the overheat alarming function work?
When the actual temperature sensed by the sensor is higher or lower than the set temperature by +5℃, the overheat alarming light will flicker (with an interval of 1S), accompanied by buzzing (with an interval of 0.5S). Pressing the buzzing releasing button will release the buzzing, but the red light will keep flickering. Pressing the button again will not recover the buzzing. The buzzing releasing button can only reset to recover the buzzing function when the temperature is within +5℃ above or below the set temperature, or when the power is cut. If the freezing sensor is in error, the red light may keep flickering with an interval of 1S and the alarming will fail.
What happens when the freezing sensor is in error?
When the freezing sensor is in error (short circuit or open circuit), the temperature value displayed will be “F1”. The frozen food cabinet enters protecting mode and the compressor alternates between 20min on and 5min off, with alarming in failure. If the refrigerator is in quick-freeze status, it will quit (the corresponding light will be off).
What is the break down memory function?
When the frozen food cabinet is broken down and electrified again, the memory function can operate according to the status set before breaking down. The display control order is quick freeze, then normal control, F1 display, and finally temperature display.
How to operate the control system (DW-40L508)?
- Unlock: Press the " " button for at least 5 seconds. The display panel will show “F0”, bit “0” flash, then press the " " button, the display panel show “F1”. Then press the " " button, all the keys are unlocked, then the display panel will show the actual temperature of the cabin. If there is no operation for 10 seconds, the keys will be locked.
- Temperature setting: At the Unlocked status, press the " " button, the display panel will show “L0”, Bit “0” flash, press the " " button again, it will show the set value, the second bit of the set value will flash. Press the " " button to change the bit, then press the " " button to change the value to -40 degrees, or another value you need.
- Temperature Calibration: At unlocked status, press the " " button and " " button at the same time for at least 5s, the display will show the value of calibrate. For example, if the display value is -40℃ and the real temperature is -35℃, input +5℃, then the LED will show -35℃. The range of calibration is -5 to +5℃.
How does the press (compressor) turn on and off?
When the inner temperature reaches the set temperature, the sensor measures the temperature and converts it into an electrical signal, which is sent to the control chip of the computer board. According to a pre-set procedure, the chip sends a stop order to the compressor to shut it down. When the inner temperature returns 1℃ higher than the set temperature, the chip sends out a stop order via the same procedure to shut the compressor down. If the temperature return in the freezer is too fast (less than 5 minutes), then it is taken as 5 minutes.
How does the fan turn on and off?
The fan operates synchronously with the compressor.
What should be done if the press (compressor) cannot start?
- The fuse is burned out: Change the fuse.
- Connecting parts of cabinet are damaged: Change the socket connector.
- The connecting line for the electric cabinet is not in the right position: Install correctly after inspection.
- The temperature controller is in error: Adjust parameters. If the temperature controller is damaged, change it.
- The starter or thermal protector is damaged: Change the starter or thermal protector.
- The press (compressor) is in error: Change the press.
What should be done if there is a high temperature inside the freezer?
- The set temperature is high: Reset
- The freezing agent is leaking: Find the leaking point and weld. Refill freezing agent.
- The temperature controller is damaged: Change the temperature controller.
- The capillary or system is dirty and stopped: Clean the capillary or change the filter.
What should be done if the screen doesn’t display temperature and displays E6?
- The temperature-sensing probe is in a short or open circuit: Inspect the temperature sensing probe.
- Without a temperature sensing probe: Install a temperature sensing probe.
What should be done if there is a big noise?
- The freezer is not even: Change the position of the freezer.
- Sympathetic vibration between pipelines or freezers when the press is operating: Clear up the pipelines to avoid sympathetic vibration.
- The fan and fan bracket are loose: Re-fix.
- Connection bolts of the press are loosened: Tighten the inner connecting bolts.
What are some frequently asked questions and answers?
| Question | Answer | Measures Able to Adopt |
|---|---|---|
| Inner temperature is too high or too low. | Can be resolved by adjusting and controlling the temperature. | See detailed operation in the instruction manual. |
| Sides of the freezer are hot. There is anticoagulant near the freezer open on the side surface. | Heating is normal instead of an error. | Can turn off the electric heating switch. |
| There is a difference between the displayed temperature and the detected temperature. | The displayed temperature is the temperature on the sensing probe. It is normal to have a difference with that of the freezer. | Normal situation needs no resolution. |
| The alarming rings in a short time after start up. | Alarm when the inner temperature is within the alarming region. | Normal situation needs no resolution. |
| Why is there serious frosting in DW-40L508 series? | It may be caused by a loose door or frequent opening of the door, or one of the small holes allowing the condenser to enter the freezer is not plugged up. | This needs to be disposed of by service persons. Moreover, regular defrosting is required to keep a better effect, normally once per 1-2 months. |
| Error of DW-40L508 series sensors and how does the press operate? | During the operation of the DW-40L508 low temperature reserving box, when the freezing sensor is in error (short circuit or open circuit), the temperature value displayed will be “E6”; the frozen food cabinet enters protecting mode and the compressor is in fixed alternation of 20min on and 5min off with alarming in failure; if the freezer is in quick-freeze status, quit (the corresponding light will be off). | |
| What is the temperature setting range for the DW-40L508 series machine? | The set range is -20~-40℃. |
What are the cooling unit parts?
| Part description | Parameter | Models |
|---|---|---|
| compressor | Secop/Danfoss SC21CL power 220-240V/50Hz Start capacitance 117-7040(80uF) | DW-40L508/348 |
| compressor | Secop/Danfoss SC18CLX.2 power 208-230V/60Hz Start capacitance 117-7066(80uF) | DW-40L508 |
| compressor | Secop/Danfoss SC12CLX.2 power 220-240V/50Hz/60Hz Start capacitance 117U5019(80uF) | DW-40L278 |
| Refrigerant | R404a | DW-40L508/348/278 |
| Fan motor | EBM AC230V/50/60Hz | DW-40L508/348/278 |
| Display panel | 0071800050C,Haier PCB | DW-40L508/348/278 |
| control panel | 0071800049C,Haier PCB | DW-40L508/348/278 |
What is an example of a product nameplate?
The nameplate includes the model number, refrigerant type and amount, inner temperature range, anti-shock safety classification, effective volume, power connection type, rated voltage and frequency, foaming cabinet type, manufacture date and number (in barcode), power input, rate current, climate class, and weight.
What are the fault codes?
- Ambient temperature sensor fault code: “E0”
- Low battery fault code: “E5”
- Inside the main sensor fault code: “E6”
- High-Temperature alarm code: “E9”
- Low temperature alarm code: “E10”
- Ambient temperature is too high alarm code: “E14“
What are the refrigerant details?
| Type | DW-40L278 | DW-40L348 | DW-40L508 |
|---|---|---|---|
| Refrigerant | R404a 215g | R404a 196g | R404a 245g |
Note: The refrigerant type and weight on the nameplate shall not be misused.
What are some troubleshooting steps for when the compressor fails to start?
| Fault | Analysis | Maintenance Measures |
|---|---|---|
| Compressor fails to start | Machine storehouse wiring connector plugs are damaged | Change the connector plugs |
| Bas wire contact | Check contact and make in good condition. | |
| Display panel connection failure | Checking if it is due to bad connection, otherwise, change it. | |
| Relay, start capacitor or heat protector is damaged | Change the part. | |
| Compressor fault | Change the compressor | |
| User’s voltage is too low | Add a manostat | |
| Fan does not rotate | Fan wiring is loose | Checking the wiring |
| Fan blades are blocked by foreign matters | Checking and clean them | |
| Fan is damaged | Change parts | |
| High temperature in the cabinet | The temperature setting of outage is too high. | Re-set computer board |
| Refrigerant leaks. | Find leak location and make repair welding. Infuse refrigerant again. | |
| Temperature probe is damaged | Change parts | |
| Capillary tube or system is blocked by dirt\ greasy | Clean the capillary tube or change filter. | |
| High ambient temperature | Turn on air-conditioner,reduce ambient temperature. | |
| Condenser blockage | Clean condenser | |
| Display board displays E6 | Temperature probe short circuit or disconnect | Checking the temperature probe |
| No temperature probe | Install a temperature probe |
What to check when there is poor cooling?
| Condition | Check |
|---|---|
| High-temperature stage fan is normal | Check the fan and the control circuit |
| Low-temperature stage fan is normal | Check the fan and the control circuit |
| Freezer temperature ≥ high-temperature alarm set temperature | Check the compressor and control circuit |
| High-temperature alarm lights flashing | Check the display board LED lights and control circuit |
| After 15 minutes flashing alarm, sound alarm | Check the control panel buzzer and control circuits |
| Test Input voltage display is normal | Check the compressor and control circuit |
| Low-temperature stage compressor is normal | Check whether there is a refrigerant leakage, repair leakage |
| High-temperature stage compressor is normal |
What are the spare parts for the DW-40L278?
| No. | Part code | Name | Qty | Remark |
|---|---|---|---|---|
| 1 | 0270100499 | Top cover | 1 | |
| 2 | 0271800064 | USB board | 1 | Optional |
| 3 | 0074091430A | Battery | 1 | |
| 4 | 0034000993 | Relay 220V | 1 | |
| 5 | 0074090950 | Wire connecting board | 1 | |
| 6 | 0071800049C | Control board | 1 | |
| 7 | 0270101421 | Electric support | 1 | |
| 8 | 0070401235 | Battery switch | 1 | |
| 9 | 0270101384 | Back cover of the electrical box | 1 | |
| 10 | 0270400062 | Power cable (European type) | 1 | |
| 11 | 0270802659 | Main body | 1 | |
| 12 | 0270801061 | Lock assy | 1 | |
| 13 | 0270200560 | Lock cover | 1 | |
| 14 | 0270100482 | Back cover of cabin | 1 | |
| 15 | 0070701061 | Drier filter | 1 | |
| 16 | 0270100082 | Filter support | 1 | |
| 17 | 0274000190 | Compressor SC12CLX.2 | 1 | 220V/50/60Hz |
| 17 | 0274000380 | Compressor NLE12.6CNL | 1 | After 2017.2.16 |
| 18 | 0270101748 | Bottom fix board of compressor | 1 | |
| 19 | 0270101786 | Back castor fix support | 1 | |
| 20 | 0270100483 | Front castor support | 1 | |
| 21 | 0270800056 | Front castor | 2 | |
| 22 | 0074090858 | Fan-motor | 1 | |
| 23 | 0071220036 | Fan support | 1 | |
| 24 | 0070701642 | Condenser | 2 | |
| 25 | 0270101747 | Front cover | 1 | |
| 26 | 0074090520 | Temp recorder | 1 | Optional |
| 27 | 0070106170 | Door support | 1 | |
| 28 | 0270100398 | Lower hinge support | 1 | |
| 29 | 0270100380 | Lower hinge | 1 | |
| 30 | 0270802653 | Door | 1 | |
| 31 | 0270200538F | Outer gasket | 1 | |
| 32 | 0270200607B | Inner gasket | 1 | |
| 33 | 0270101276 | Lock ring | 1 | |
| 34 | 0270801098 | Handle | 1 | |
| 35 | 0270700281 | Evaporator | 1 | |
| 36 | 0270200183 | Drawer | 6 | |
| 37 | 0270101174 | Lock | 1 | |
| 38 | 0074090530 | Door ajar switch | 1 | |
| 39 | 0270101746 | Upper front cover | 1 | |
| 40 | 0270200033 | Display panel support | 1 | |
| 41 | 0071800050C | Display board | 1 | |
| 42 | 0270200604B | Seal for top cover | 1 | |
| 43 | 0270101754 | Upper panel Support | 2 | Old version |
| 44 | 0270100378 | Upper hinge | 1 |
What are the spare parts for the DW-40L348?
| No. | Part code | Name | Qty | Remark |
|---|---|---|---|---|
| 1 | 0071800050C | Display board | 1 | |
| 2 | 0270102132 | Upper front cover | 1 | |
| 3 | 0270801087 | Upper door | 1 | |
| 4 | 0270801098 | Handle | 2 | |
| 5 | 0270801090 | Lower door | 1 | |
| 6 | 0270101548 | Front cover of cabin | 1 | |
| 7 | 0074090520 | Temperature recorder | 1 | Optional |
| 8 | 0070701642 | Condenser | 2 | |
| 9 | 0074090858 | Fan | 1 | |
| 10 | 0274000065 | Solenoid valve | 1 | |
| 11 | 0074090620 | Compressor SC21CL | 1 | Before 2017.2.16 |
| 11 | 0274000380 | Compressor NLE12.6CNL | 1 | After 2017.2.16 |
| 12 | 0070701061 | Drier filter | 1 | |
| 13 | 0270101389 | Back cover of cabin | 1 | |
| 14 | 0270100380 | Lower hinge | 1 | |
| 15 | 0270100379 | Middle hinge | 1 | |
| 16 | 0270801081 | Main body | 1 | |
| 17 | 0070400331 | Power cord | 1 | |
| 18 | 0070401235 | Battery switch | 1 | |
| 19 | 0274000239 | Power switch | 1 | |
| 20 | 0034000993 | Relay | 1 | |
| 21 | 0271800065 | Solenoid valve control board | 1 | |
| 22 | 0074091430A | Battery | 1 | |
| 23 | 0270100405 | Top cover | 1 | |
| 24 | 0071800049C | Main board | 1 | |
| 25 | 0271800064 | USB board | 1 | Optional |
| 26 | 0270100378 | Upper hinge | 1 | |
| 27 | 0270700226 | Condenser | 1 | |
| 28 | 0270200602 | Drawer | 12 | |
| 29 | 0270200608 | Outer gasket | 2 | |
| 30 | 0270200607 | Inner gasket | 2 | |
| 31 | 0270101276 | Lock ring | 2 | |
| 32 | 0270200560 | Lock cover | 2 | |
| 33 | 0270801061 | Lock assy | 2 |
What are the spare parts for the DW-40L508?
| NO. | Part code | Name | Qty | Remark |
|---|---|---|---|---|
| 1 | 0071800050C | Display board | 1 | |
| 2 | 0270102132 | Upper front cover | 1 | |
| 3 | 0270800397 | Upper door | 1 | |
| 4 | 0270801098 | Handle | 2 | |
| 5 | 0270800398 | Lower door | 1 | |
| 6 | 0270100397 | Front cover of cabin | 1 | |
| 7 | 0074090520 | Temperature recorder | 1 | Optional |