What is the important notice regarding the use of the FLOMEC TM150-LP?

Use TM Series meters like the FLOMEC TM150-LP with water and other chemicals compatible with wetted components. Do not use to meter fuel or incompatible chemicals. This meter features a computer for local electronic display plus a pulse output cable delivering raw pulses from the meter electronics to provide a digital signal to customer interfacing equipment. The computer display measures in gallons or litres.

These meters are not legal for trade applications.

TM Series meters are very sensitive to electric noise if operated within 1 to 2 inches of some electric motors or other sources of electronic noise.


How do I install the FLOMEC TM150-LP water meter?

Install your meter in-line either horizontally or vertically or at the end of the hose adjacent to the nozzle. Installation to metal connections is not recommended. Install as follows:

1. Plan to install the turbine with a minimum straight pipe length as follows:

• Upstream from the turbine, allow a minimum straight pipe length of 10 times the internal diameter of the turbine.

• Downstream from the turbine, allow a minimum straight pipe length of 5 times the internal diameter of the turbine.

2. For Spigot (Pipe) End use only primer and solvents approved for PVC gluing.

For NPT Fittings wrap all connections with 3 to 4 wraps of thread tape (optional to use pipe thread sealant). Make sure the tape does not intrude into the flow path.

3. Attach the meter with the arrow pointed in the direction of fluid flow.

4. For NPT Fittings – Hand tighten the meter at the housing ends. Do not use a wrench or similar tool to tighten. This can damage the housing.


What are the operational warnings and cautions for the FLOMEC TM150-LP?

WARNINGS:

• Compatibility of this product’s material and the process fluid and/or environment should be considered prior to putting into service.

• Product should never be operated outside its published specifications for temperature or pressure. See specifications for your model.

• Make sure flow and pressure have been eliminated from the process pipe prior to installing or removing the product.

• Always use appropriate thread sealant when connecting the product to process piping.

CAUTIONS:

• To protect against leakage, seal all pipe threads with an appropriate sealing compound. Make sure the sealing compound does not intrude into the flow path.

• Installation near high electromagnetic fields and high current fields is not recommended and may result in inaccurate readings.

NOTE: If connecting to new male pipe threads, burrs and curls can adversely affect accuracy. Correct the problem prior to turbine installation.


How does the output pulse on the FLOMEC TM150-LP work?

The output pulse through the cable is a raw pulse. For each rotation of the turbine rotor, a specific number of pulses are transmitted via the attached cable. Pulse amounts can vary depending on pipe/meter size, flowrate, fluid type, etc. The pulse cable White wire is signal and the Black wire is common (GND).

NOTE: Some interface devices may not have an internal pull-up resistor. Use a minimum 820 ohms resistor if necessary.

The table below shows typical pulses per gallon for different meter sizes.

Meter Size Typ. Pulses per Gallon
TM050 2,400
TM075 1,100
TM100 570
TM150 213
TM200 100

How can I verify the accuracy of my FLOMEC TM150-LP meter?

Before using, check the meter’s accuracy and verify calibration by following these steps:

1. Make sure there is no air in the system by starting the flow until it runs steadily. Then, stop or divert the flow using a valve or nozzle.

2. Meter an exact known volume into an accurate container. For best results, meter with one continuous full stream.

3. Check the volume against the display or recording equipment. If the amount metered is accurate, further calibration is not necessary. If not, refer to the Calibration Section for further instructions.


How do I use the computer display on the FLOMEC TM150-LP to check totals?

The computer on the FLOMEC TM150-LP maintains two totals:

Cumulative Total (TOTAL 1): Provides continuous measurement and cannot be manually reset.

Batch Total (TOTAL 2 BATCH): Can be reset to measure flow during a single use.

When the Cumulative Total reaches 999,999, an X10 icon will be highlighted, indicating a zero must be added to the 6 digits shown. On the next rollover, an X100 icon will appear, indicating two zeros must be added.

Press the DISPLAY button briefly to switch between TOTAL 1, TOTAL 2 BATCH, and FLOWRATE. To reset the Batch Total, press DISPLAY briefly to show TOTAL 2 BATCH, then hold the DISPLAY button for 3 seconds until it resets to zero.

When fluid is flowing, a small propeller icon is highlighted.


How do I use the flowrate feature on the FLOMEC TM150-LP?

To use this feature, press and release the DISPLAY button until the FLOWRATE icon appears. The factory-set time base will be highlighted to the right of FLOWRATE (M = minutes, H = hours, D = days). When FLOWRATE is invoked, the display will indicate the rate of flow.


How do I manage the factory and field calibration settings on the FLOMEC TM150-LP?

All calibration information is visible as icons on the top line of the display. All units are configured with a “factory” calibration (indicated with FAC), which is permanently programmed and not user-adjustable. Both gallons (“GL”) and litres (“LT”) are available.

To toggle between factory units (gallons, litres, and possibly others like imperial gallon, quart, cubic feet, etc.), hold the CALIBRATE button and briefly press the DISPLAY button. Switching between units does not corrupt the totals.

The “field” calibration can be set, changed, or modified by the user at any time using the calibration procedure. Totals or flowrate derived from the field calibration are used when the FAC icon is no longer visible on the display.


What are the minimum flowrate requirements for the FLOMEC TM150-LP and other TM Series Meters?

To ensure accurate results, especially during calibration, you must meet the meter’s minimum flowrate requirements.

TM Series Meters
1/2 inch meter 1 GPM (3.8 LPM)
3/4 inch meter 2 GPM (7.5 LPM)
1 inch meter 5 GPM (18.8 LPM)
1 1/2 inch meter 10 GPM (37.5 LPM)
2 inch meter 20 GPM (75 LPM)

How do I perform a field calibration on the FLOMEC TM150-LP?

Use the following correction factor method for field calibration:

1. Press and hold the CALIBRATE and DISPLAY buttons for about 3 seconds until you see FLdCAL. Release both buttons, and you will see CF – 00.0. You are now in the field calibration mode, where values from -99.9% to +99.9% can be entered.

2. The +/- position appears as an “underscore” for plus or a “hyphen” for minus. The DISPLAY button selects the position, and the CALIBRATE button toggles this character.

3. Press the DISPLAY button to select the numeric positions. Press the CALIBRATE button to scroll from 0 to 9. Enter the percentage of change you want the display to correct. When satisfied, press both CALIBRATE and DISPLAY buttons simultaneously. CALEnd will be displayed, and the unit will return to normal operation without the FAC (factory calibration) icon.

4. The entered correction will be applied to all enabled units.

5. To return to factory calibration (FAC), press and hold both CALIBRATE and DISPLAY buttons for about 3 seconds until FACCAL is displayed. Then release the buttons. The unit will return to normal operation, and the FAC icon will be visible.


What maintenance is required for the turbine rotor on the FLOMEC TM150-LP?

The meter is virtually maintenance-free. However, it is important that the rotor moves freely. Keep the meter clean and free of contaminants.

If the rotor does not turn freely, apply a penetrating lubricant on the rotor, shaft, and bearings. Remove any debris or deposits from the rotor using a soft brush or small probe. Be careful not to damage the turbine rotor or supports.

CAUTIONS:

• Blowing compressed air through the turbine assembly could damage the rotor.

• Do not allow liquids to dry inside the turbine.

• Handle the rotor carefully. Small scratches or nicks can affect accuracy.


How do I replace the batteries in my FLOMEC TM150-LP?

If the display becomes dim, blank, or shows the “LobAtt” message, replace the batteries. The computer display is powered by two 3-volt lithium batteries. When batteries are removed or lose power, the batch and cumulative totals and the field and factory calibrations are retained.

Battery Replacement Steps:

1. Remove the four Phillips-head screws from the face of the meter and lift the faceplate from the turbine.

2. Remove the old batteries and clean any corrosion from the terminals.

3. Install new batteries. Make sure the positive post is in the correct position.

4. When the batteries are replaced, the faceplate will power ON. Check the display to ensure normal functions have resumed before assembling again.

5. Reseat batteries, if necessary, and position the faceplate on the turbine housing. To avoid moisture damage, make sure the seal is fully seated. Tighten the four screws on the faceplate.

WARNING: (Battery) – Avoid mechanical or electrical abuse. Batteries may explode or cause burns if disassembled, crushed or exposed to fire or temperatures in excess of 212°F (100°C). Do not short circuit or install with incorrect polarity. DO NOT INCINERATE.

CAUTION: Batteries should ONLY be replaced with P/N 113520-1 Kit (Includes two each P/N 902004-2 Batteries). Do not mix old with new. Do not use other brands or technologies.


What are the specifications for the FLOMEC TM150-LP meter?

Unit of Measure: Gallon

Accuracy with Computer: ± 3.0% of reading (Accuracy can be improved with field calibration)

Operating Temperature: +32° to +140° F (Do not allow fluid to freeze inside meter.)

Storage Temperature: -40° to +158° F

Design Type: Turbine

Max. Working Pressure: 225 PSIG @ 73° F

Cable Length: 5 FT.

Wetted Components:

• Housing: PVC

• Journal Bearings: Ceramic

• Shaft: Tungsten Carbide

• Rotor and Supports: PVDF

• Retaining Washer: Stainless Steel

Inlet and Outlet:

Spigot (Pipe) End Models Description
TM050-LP 1/2 inch Schd. 80, Spigot (Pipe)
TM075-LP 3/4 inch Schd. 80, Spigot (Pipe)
TM100-LP 1 inch Schd. 80, Spigot (Pipe)
TM150-LP 1 1/2 inch Schd. 80, Spigot (Pipe)
TM200-LP 2 inch Schd. 80, Spigot (Pipe)

NPT Models Description
TM050-N-LP 1/2 inch NPT
TM075-N-LP 3/4 inch NPT
TM100-N-LP 1 inch NPT
TM150-N-LP 1 1/2 inch NPT
TM200-N-LP 2 inch NPT

Flow Range:

1/2 inch 1 – 10 GPM
3/4 inch 2 – 20 GPM
1 inch 5 – 50 GPM
1 1/2 inch 10 – 100 GPM
2 inch 20 – 200 GPM

Product Weight:

Size Spigot (Pipe) NPT
1/2 in. .38 lbs. .55 lbs.
3/4 in. .43 lbs. .67 lbs.
1 in. .49 lbs. .84 lbs.
1 1/2 in. .66 lbs. 1.38 lbs.
2 in. .78 lbs. 1.78 lbs.

Dimensions – Inches (W x H x L):

Size Without Fitting With NPT Fitting
1/2″ 2.1 x 2.5 x 4.3 2.1 x 2.7 x 6.0
3/4″ 2.1 x 2.7 x 4.4 2.1 x 2.9 x 6.1
1″ 2.1 x 2.9 x 4.5 2.1 x 3.1 x 6.5
1 1/2″ 2.1 x 3.6 x 5.4 2.3 x 3.8 x 7.6
2″ 2.4 x 4.1 x 5.5 3.5 x 4.4 x 7.9

What replacement parts are available for the FLOMEC TM150-LP and other TM Series meters?

The following replacement parts and accessories are available:

Part No. Description
113520-1 Battery Replacement Kit
116000-1 Calibration Container, Large (5 gallon)
125508-03 1/2 inch, Turbine Assy Kit
125508-04 1/2 inch NPT, PVC Turbine Assy Kit
125510-03 3/4 inch, Turbine Assy Kit
125510-04 3/4 inch NPT, PVC Turbine Assy Kit
125512-03 1 inch, Turbine Assy Kit
125512-04 1 inch NPT, PVC Turbine Assy Kit
125514-03 1 1/2 inch, Turbine Assy Kit
125514-04 1 1/2 inch NPT, PVC Turbine Assy Kit
125516-03 2 inch, Turbine Assy Kit
125516-04 2 inch NPT, PVC Turbine Assy Kit
901002-52 Seal

Computer Kits:

Part No. Description
125509-04 1/2 inch, Computer Assy Kit w/Pulse
125511-04 3/4 inch, Computer Assy Kit w/Pulse
125513-04 1 inch, Computer Assy Kit w/Pulse
125515-04 1 1/2 inch, Computer Assy Kit w/Pulse
125517-04 2 inch, Computer Assy Kit w/Pulse

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD FLOMEC TM150-LP (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.