Free English ECCOTEMP 6.8GB-ING (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD ECCOTEMP 6.8GB-ING (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

What are the temperature rise and flow rates for the ECCOTEMP 6.8GB-ING?

The following table outlines the flow rates (in Gallons Per Minute) relative to the temperature rise (in degrees Fahrenheit) for the ECCOTEMP 6.8GB-ING water heater:

MODEL FLOW U/M 80° Rise 75° Rise 70° Rise 65° Rise 60° Rise 55° Rise 50° Rise 45° Rise 40° Rise 35° Rise 30° Rise
6.8GB/6.8GB-I gpm 1.3 1.9 2.6 3.2 3.9 4.5 5.2 5.8 6.4 7.1 7.7

What should I do if I smell gas near my ECCOTEMP 6.8GB-ING?

If you smell gas, follow these steps immediately:

1. DO NOT try to light any appliances.

2. DO NOT touch any electrical switch; do not use any phone in your building.

3. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

4. If you cannot reach your gas supplier, call the fire department.

5. DO NOT return to your home until authorized by the gas supplier or fire department.


How do I connect and install the remote control for the ECCOTEMP 6.8GB-ING?

To connect the remote control:

1. For one remote control: Plug the aviation joint into the socket directly on the water heater.

2. For two remote controls: First, cut off the aviation joints on the two controllers, plug one into the socket on the water heater (length is dependent on your requirements), and throw away the other. Then connect the wires of the aviation joint to the inlet wire of the connector, and connect the two remote controls to the outlet wires of connector.

To mount the remote control:

1. Remove the front cover of the Remote Control.

2. At the installation site, mark and screw two holes with 1/4” width and 1 1/5” depth. Insert two (2) rubber screws into the holes. Place the remote control against the wall, align the holes of control with the holes in the wall, and fasten them with wood thread screws.

3. Replace the front cover on the remote control.


How do I start the ECCOTEMP 6.8GB-ING water heater?

Before operating, ensure you read all safety labels. This water heater does not have a pilot; it is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

1. STOP! Read the safety information on the label.

2. Turn off all electric power to the appliance.

3. Set the thermostat to the lowest setting.

4. DO NOT attempt to light the burner by hand.

5. Turn the Gas Shut-Off Valve located on the outside of the unit clockwise to the “OFF” position.

6. Wait five (5) minutes to clear out any gas. If you smell gas, STOP and follow gas safety instructions. If you don’t smell gas, go to the next step.

7. Turn the Gas Shut-Off Valve located on the outside of unit counterclockwise to the “ON” position.

8. Turn on all electric power to the appliance.

9. Set thermostat to desired setting.

10. If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.


How do I turn on the ECCOTEMP 6.8GB-ING for use?

1. Make sure the gas type you will use is the same as the type on the data plate.

2. Turn on the main gas valve, plug in the power cord (be sure the socket is well grounded), and press the “ON/OFF” button on the control panel. Set temperature to 120°F.

3. Turn on the faucet, and the fan will begin working. You will hear the ignition sound after a few seconds. The burner will ignite, and hot water will come out. If the burner is not ignited successfully, the ignition sound will last a few seconds. If the burner still fails to ignite, turn off the faucet and wait for 10-20 seconds, and repeat the above procedures.


How do I set the water temperature on the ECCOTEMP 6.8GB-ING?

The temperature can be set using the remote control. The factory preset is 110°F, and the range is between 90°F and 140°F.

1. To turn the remote control ON or OFF, press the POWER button for more than 3 seconds.

2. To adjust the temperature to a required setting, in “priority” mode, press the UP or DOWN temperature button. Press and hold UP or DOWN to raise or lower the temperature continuously.

3. When the water heater is in use, the set temperature can increase to 122°F, but there is no limit to temperature decrease. To increase the temperature more than 122°F, the water will need to be shut off first.

Note: If the BATH control is turned on, the temperature setting on the MAIN control cannot be changed. The BATH control(s) will always have PRIORITY over the MAIN control.


How does the temperature memory function work on the ECCOTEMP 6.8GB-ING?

This model can memorize and save the last set temperature on the remote control with “priority”. If no remote control has “priority”, the set temperature of the water heater will be the same as the set temperature of the remote control which starts the water heater.


How do I clean the water filter on the ECCOTEMP 6.8GB-ING?

1. Make sure the water heater is OFF and the electrical power supply has been disconnected.

2. Turn the water supply OFF to the heater.

3. Unscrew the water filter, and slide the filter out.

4. DO NOT tap the filter as it may deform and/or damage the filter.

5. To remove severe dust, use a soft brush and wash with running water.

6. Return the filter to the water heater and screw in the filter.

7. Turn the electrical power supply and cold water supply ON to the water heater.


What is the recommended cleaning routine for the ECCOTEMP 6.8GB-ING?

To prevent water scale, lime, or rust deposit buildup and ensure your tankless water heater is running as efficiently as possible, it is highly recommended that you clean your tankless water heater every 6 months. To do this, use an EZ-Flush System Descaler Kit.


How should I clean the exterior and remote of the ECCOTEMP 6.8GB-ING?

Vacuum around the water heater for dust, dirt, and lint on a regular basis. Clean the water heater and remote control by using a damp soft cloth with a few drops of mild detergent and gently wiping the surfaces. Wipe any remaining moisture with a dry soft cloth. DO NOT scrub with a brush. DO NOT splash water on the remote controls.


What should be done for vacation or extended shut-down of the ECCOTEMP 6.8GB-ING?

If the water heater is to remain idle for an extended period, the power and water to the appliance should be turned off. If there is no power to the water heater, freeze protection does NOT work. The water heater and piping should be drained if they might be subjected to freezing temperatures. After a long shut-down period, the water heater’s operation and controls should be checked by qualified service personnel.


How do I drain the ECCOTEMP 6.8GB-ING to prevent freezing?

When the temperature falls below 32°F, follow these steps to drain the water heater:

1. Turn off the switch on the remote control.

2. Close the gas shut-off valve(s).

3. Close the water shut-off valve.

4. Turn the on/off switch to the OFF position and disconnect the breaker at least 10 seconds after step #1.

5. Open the drain valve.

6. Open all hot water faucets. Before proceeding, make sure that COLD water is coming out of all hot water faucets.


How do I return the ECCOTEMP 6.8GB-ING to operation after draining?

1. Reinstall the water filter. Close the hot water outlet drain valve.

2. Open the water shut-off valve and close again after making sure that water comes out from hot water faucets (This step is to remove air from the water lines).

3. Reconnect the breaker and turn the on/off switch to the ON position, fully open the gas shut-off valve and the water shut-off valve.


How can I troubleshoot common problems with the ECCOTEMP 6.8GB-ING?

Problem Possible Cause What to do
Not enough or no hot water Water shut-off valve is not fully opened. Check shut-off valve and open fully.
Hot water faucet is not fully opened. Open hot water faucet completely. (The main burner goes off when incoming water volume is inadequate.)
Water piping is frozen. Allow piping to thaw.
No electricity or water supply is cut off. Check that proper power is being supplied and/or water supply is adequate.
Water heater is not “ON”. Turn the water heater “ON” by the button on the remote control.
The temperature may be set too low. Increase the temperature setting.
Mixing Valve malfunction (if applicable). Check and replace if necessary.
Water not hot enough The temperature may be set too low. Increase the temperature setting.
The gas valve is not fully opened. Check and open the gas valve fully.
Water too hot The temperature is set too high. Decrease the temperature setting.
Water shut-off valve is not fully opened. Check shut-off valve and open fully.
Small amount of water has been heated. Allow more water to flow.
Water filter is clogged. Clean the filter with a tooth brush.
Fan continues to rotate after hot water faucet is closed. This function is to purge unburned gas 10-15 seconds. Normal operation. There is no need to call for service. Check for error code.

What do the error codes mean on the ECCOTEMP 6.8GB-ING?

If an error code is displayed, close the hot water faucet, turn off the switch on the remote control, wait 5 minutes, turn the switch back on, and open the hot water faucet.

Error Code Error Description Possible Cause What To Do
E0 Hot water sensor failure. Junction port loose, Short circuit Call for Service
E1 Ignition system failure. The gas valve is not opened or fully opened, Water shut-off valve is not open, Junction port loose. Check and open gas fully, Check and open water valve, Call for service
E2 There is flame when no water is coming in. Electric circuit problem Call for Service
E3 Over-heating protection. Dry Combustion, Problem of overheating controller Call for Service
E4 Cold water temperature sensor. Problem with sensor, Problem with sensor’s plug or socket, None of the above Replace the sensor, Fix it, Replace the computer board
E5 Pressure Switch Motor problem, Voltage of power supply is too low Call for Service
E6 Over-Heating Gas pressure is too high, Water shut-off valve is not fully opened, The temperature is set too low Check shut-off valve and open fully, Increase temperature setting
E7 Solenoid Valve Open circuit of the valve, Short circuit of the valve, None of the above Connect the valve, Replace the valve, Replace the computer board
E8 Vent Pipe Block Vent pipe is blocked Clean the pipe