What parts are included in the package of the DEYE SUN-20K-G02-LV?

The following parts are included in the package for the DEYE SUN-20K-G02-LV:

1. Grid-tied PV String Inverter x 1

2. Wall mounting bracket x 1

3. Mounting stainless steel screws M4x12 x 10

4. Wrench x 1

5. DC power connectors (8 pairs for 20Kw model)

6. Stainless steel anti-collision bolt M12x80-304 x 3

7. User manual x 1

8. Datalogger (optional) x 1

9. Installation screws M5x12 x 2

10. SUN limiter (optional) x 1 (includes 3pcs CT when ordered)

11. Sensor Clamp x 3

12. Meter (optional) x 1


What do the safety signs on the DEYE SUN-20K-G02-LV mean?

The DEYE SUN-20K-G02-LV uses several safety symbols to indicate potential risks:

Warning: Indicates important safety instructions which, if not correctly followed, could result in serious injury or death.

Shock Hazard: Indicates important safety instructions which, if not correctly followed, could result in electric shock.

Safety Hint: Indicates important safety instructions which, if not correctly followed, could result in damage to or destruction of the inverter.

High Temperature Hazard: Indicates safety instructions regarding hot surfaces which, if not correctly followed, could result in burns.


What are the safety requirements for using the DEYE SUN-20K-G02-LV?

The following requirements must be met when operating the DEYE SUN-20K-G02-LV:

1. The inverter should be installed and maintained by a qualified person under local standard regulations.

2. You must disconnect the AC side first, then disconnect the DC side during installation and maintenance. After that, wait at least 5 minutes to avoid getting shocked.

3. The local temperature of the inverter may exceed 80 degrees Celsius while operating. Do not touch the case to avoid injury.

4. All electrical installations must be in accordance with local electrical standards and achieve permission from the local power company.

5. Take appropriate anti-static measures.

6. Install the unit where children cannot touch it.


How do I interpret the status indicator lights on the DEYE SUN-20K-G02-LV?

The DEYE SUN-20K-G02-LV features four LED indicators on the front panel:

IndicatorStatusExplanation
DC (Green)OnInverter detects DC input
DC (Green)OffLow DC input voltage
AC (Green)OnGrid Connected
AC (Green)OffGrid Unavailable
NORMAL (Green)OnUnder normal operating
NORMAL (Green)OffStop operating
ALARM (Red)OnDetected faults or report faults
ALARM (Red)OffUnder normal operating

What are the button functions on the DEYE SUN-20K-G02-LV operation panel?

The DEYE SUN-20K-G02-LV panel has four buttons with the following functions:

Up Button: Used for page turning and increasing values.

Down Button: Used for page turning and decreasing values.

ESC Button: Used for exiting or modifying adjustable parameters.

ENTER Button: Used for confirming selections or modifying adjustable parameters.


What criteria should be considered when selecting an installation location for the DEYE SUN-20K-G02-LV?

When choosing a location for the DEYE SUN-20K-G02-LV, follow these guidelines:

1. Do not install in areas containing highly flammable materials or gases.

2. Do not install in potentially explosive atmospheres.

3. Do not install in small closed spaces where air cannot circulate freely. Ensure air flow around the inverter is not blocked.

4. Avoid exposure to direct sunlight, as this increases operational temperature and may cause power limiting. Use a sun shade if ambient temperatures exceed 40 degrees Celsius.

5. Install on a wall or strong structure capable of bearing the inverter’s weight.

6. Install vertically with a maximum incline of +/-15 degrees.

7. If installing multiple inverters, leave at least a 500mm gap between each unit and 500mm above and below.


What are the steps for the physical installation of the DEYE SUN-20K-G02-LV?

Follow these steps to mount the DEYE SUN-20K-G02-LV:

1. For brick walls, determine the position of the holes suitable for the expansion bolts.

2. Ensure the bracket is horizontal and marks the mounting holes correctly.

3. Drill the holes on the wall according to the marks.

4. Use the expansion bolts to fix the mounting bracket to the wall.

5. Mount the inverter onto the bracket in a vertical position.

6. Secure the inverter to the bracket using the M12x80 stainless steel screws.


How do I connect the DC input terminals to the DEYE SUN-20K-G02-LV?

To connect the PV array to the DEYE SUN-20K-G02-LV, follow these procedures:

1. Switch the Grid Supply Main Switch (AC) to OFF.

2. Switch the DC Isolator to OFF.

3. Strip off the DC wire about 7mm and disassemble the connector cap nut.

4. Crimp the metal terminals with crimping pliers to the wire.

5. Insert the contact pin into the top part of the connector and screw up the cap nut.

6. Finally, insert the DC connector into the positive and negative inputs of the inverter.

Safety Note: Ensure the PV array open circuit voltage is within 1000V and that polarity matches the DC+ and DC- symbols.


What are the cable specifications for the DC connection on the DEYE SUN-20K-G02-LV?

The recommended DC cable specifications for the DEYE SUN-20K-G02-LV are:

Cable TypeCross Section Range (mm2)Recommended Value (mm2)
Industry generic PV cable (model: PV1-F)4.0 to 6.0 (12 to 10 AWG)4.0 (12 AWG)

How do I perform the AC terminal connection for the DEYE SUN-20K-G02-LV?

To connect the AC side of the DEYE SUN-20K-G02-LV, follow these steps:

1. Remove the 8 fixing screws on the AC junction box of the inverter to access the terminals.

2. Connect the cable through the junction box and waterproof jacket.

3. Insert the wires into the terminals: L1 to socket 1, L2 to socket 2, L3 to socket 3, PE line to the earth, and N wire to the N socket.

4. Use a hexagon screwdriver to press the wiring harness to the connection terminals.

5. Screw the AC connection cover back to the shell and tighten all screws and the waterproof protection connector.

Recommended Copper Core Cable: 25 to 50 mm2.


How do I start up and shut off the DEYE SUN-20K-G02-LV?

To start up the DEYE SUN-20K-G02-LV:

1. Switch on the AC breaker.

2. Turn on the DC switch of the PV module. If there is sufficient voltage, the inverter will start.

3. The inverter will self-check internal and grid parameters. If ranges are acceptable, it will generate energy and the NORMAL indicator will light up.

To shut off the DEYE SUN-20K-G02-LV:

1. Switch off the AC breaker.

2. Wait 30 seconds and turn off the DC switch or disconnect the DC input connector.

3. The LCD and all LEDs will close within two minutes.


How do I set up the Zero-export function with a SUN limiter on the DEYE SUN-20K-G02-LV?

To enable the zero-export function on the DEYE SUN-20K-G02-LV using the SUN limiter:

1. Turn on the AC switch and the DC switch, and wait for the inverter LCD to light up.

2. Press Enter on the LCD panel to go to the menu, select [parameter setting], then [run param].

3. Input the default password “1234”.

4. Navigate to the “Limiter” option and change it to “ON”.

5. Move the cursor to [confirm] and press ENTER to save settings.

6. If successful, the home page will display [utility power].


What are the common error codes and solutions for the DEYE SUN-20K-G02-LV?

Below are several common error codes for the DEYE SUN-20K-G02-LV and their recommended actions:

CodeDescriptionSolution
F01DC input polarity reverse faultCheck the PV input polarity.
F02DC insulation impedance permanent faultCheck the grounding cable of the inverter.
F04Ground fault GFDICheck the solar panel output connection.
F05Read the memory errorRestart the inverter; if it persists, contact service.
F13Working mode changed/Grid mode changedCheck for lost phase or AC voltage detection circuit issues. Restart the inverter.
F15AC firmware over currentCheck internal AC sensor or connection wire on control board. Restart inverter.
F24DC insulation impedance failureCheck PV panels and ensure the aluminum frame and inverter are grounded well.
F35No AC gridCheck AC grid voltage and ensure the AC connector is in good condition.
F55DC busbar voltage is too highCheck PV voltage. If it exceeds limits, reduce the number of solar panels in series.
F56DC busbar voltage is too lowCommon in early morning. If it persists during operation, check PV and Ubus voltage.
F64IGBT heat sink high temperatureCheck the temperature sensor and ensure the inverter is the correct model. Restart inverter.

What are the technical specifications for the DEYE SUN-20K-G02-LV?

The technical specifications for the DEYE SUN-20K-G02-LV are as follows:

ParameterValue
Max. DC Power26 kW
Max. DC Input Voltage800 V
Start-up DC Input Voltage250 V
MPPT Operating Range200 to 700 V
Max. DC Input Current40A + 40A
Number of MPPT/Strings per MPPT2/3
Rated Output Power20 kW
Rated AC Grid Voltage127/220 V
Rated Grid Frequency60 / 50 Hz (Optional)
Max. Efficiency98.7%
Operating Temperature-25 to 65 degrees Celsius
Ingress ProtectionIP65
Weight44.5 kg
Size (W x H x D)647.5 x 537 x 303.5 mm